Application of gold nanoparticles for improvement of analytical characteristics of conductometric enzyme biosensors

被引:14
|
作者
Soldatkin, O. O. [1 ,4 ]
Soldatkina, O., V [2 ,3 ]
Piliponskiy, I. I. [1 ]
Rieznichenko, L. S. [2 ]
Gruzina, T. G. [2 ]
Dybkova, S. M. [2 ]
Dzyadevych, S., V [1 ,3 ]
Soldatkin, A. P. [1 ,3 ]
机构
[1] NAS Ukraine, Inst Mol Biol & Genet, Zabolotnogo Str 150, UA-03143 Kiev, Ukraine
[2] NAS Ukraine, FD Ovcharenko Inst Biocolloidal Chem, Vernadskogo Ave 42, UA-03142 Kiev, Ukraine
[3] Taras Shevchenko Natl Univ Kyiv, Volodymyrska St 64-13, UA-01601 Kiev, Ukraine
[4] Natl Tech Univ Ukraine, Igor Sikorsky Kyiv Polytech Inst, Prosp Peremohy 37, UA-03056 Kiev, Ukraine
关键词
Biosensor; Conductometry; Enzyme; Gold nanoparticles; Acetylcholinesterase; Butyrylcholinesterase; Glucose oxidase; Bioselective elements; INHIBITION;
D O I
10.1007/s13204-021-01807-6
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In the work, the possibility of using nanoparticles of gold (AuNPs) to upgrade bioselective elements of biosensors in order to improve their analytical characteristics is considered. The bioselective elements of biosensors based on acetylcholinesterase (AChE), butyryl cholinesterase (BuChE) and glucose oxidase (GOD) were used as an experimental model. Immobilization of enzymes on the surfaces of conductometric transducers was performed by the crosslinking of corresponding enzymes using glutaraldehyde. The conditions of immobilization of AChE with gold nanoparticles were optimized. Thus, we determined the optimal values of concentration of crosslinking agent (glutaraldehyde), duration of immobilization, the enzyme to AuNPs ratio, the AuNPs concentration and size. The performance characteristics of the biosensors based on enzymes and AuNPs were investigated and compared with the characteristics of biosensors based on enzymes only. It was also examined how the addition of AuNPs to the bioselective element of biosensors affects the biosensor stability. In particular, the reproducibility of preparation and continuous operation of biosensors was tested as well as their stability at storage. It was shown that the presence of AuNPs in the composition of bioselective elements can improve some characteristics of biosensors, which may be promising for further study and use.
引用
收藏
页码:995 / 1003
页数:9
相关论文
共 50 条
  • [41] Application of Enzyme Biosensors in Analysis of Food and Beverages
    Rastislav Monosik
    Miroslav Stredansky
    Jan Tkac
    Ernest Sturdik
    Food Analytical Methods, 2012, 5 : 40 - 53
  • [42] Application of Enzyme Biosensors in Analysis of Food and Beverages
    Monosik, Rastislav
    Stredansky, Miroslav
    Tkac, Jan
    Sturdik, Ernest
    FOOD ANALYTICAL METHODS, 2012, 5 (01) : 40 - 53
  • [43] Application of enzyme-modified electrodes to biosensors
    Mizutani, F
    BUNSEKI KAGAKU, 1999, 48 (09) : 809 - 821
  • [44] Evolution of gold nanoparticles in micelle by UV-irradiation: A conductometric study
    Ghosh, SK
    Sarma, N
    Mandal, M
    Kundu, S
    Esumi, K
    Pal, T
    CURRENT SCIENCE, 2003, 84 (06): : 791 - 795
  • [45] Fluorescence quenching of fluoroquinolones by gold nanoparticles with different sizes and its analytical application
    Amjadi, Mohammad
    Farzampour, Leila
    JOURNAL OF LUMINESCENCE, 2014, 145 : 263 - 268
  • [46] Gold-nanoparticle-based biosensors for detection of enzyme activity
    Hutter, Eliza
    Maysinger, Dusica
    TRENDS IN PHARMACOLOGICAL SCIENCES, 2013, 34 (09) : 497 - 507
  • [47] Sensing characteristics of NIR localized surface plasmon resonances in gold nanorings for application as ultrasensitive biosensors
    Larsson, Elin M.
    Alegret, Joan
    Kall, Mikael
    Sutherland, Duncan S.
    NANO LETTERS, 2007, 7 (05) : 1256 - 1263
  • [48] Development of a new method of improving the oxidase-based biosensors′ analytical characteristics by adding catalase as an auxiliary enzyme
    Berketa, Kseniia
    Mruga, Daryna
    Dzyadevych, Sergei
    Soldatkin, Oleksandr
    ELECTROANALYSIS, 2023, 35 (12)
  • [49] Assessment of the toxicity of methyl parathion and its photodegradation products in water samples using conductometric enzyme biosensors
    Dzyadevych, SV
    Soldatkin, AP
    Chovelon, JM
    ANALYTICA CHIMICA ACTA, 2002, 459 (01) : 33 - 41
  • [50] Gold nanoparticles deposited on silica microparticles - Electrokinetic characteristics and application in SERS
    Lupa, Dawid
    Ocwieja, Magdalena
    Piergies, Natalia
    Balis, Andrzej
    Paluszkiewicz, Czeslawa
    Adamczyk, Zbigniew
    COLLOID AND INTERFACE SCIENCE COMMUNICATIONS, 2019, 33