An optimal tracheal tube preshaping strategy for endotracheal intubation using video laryngoscopy: a randomized controlled trial

被引:2
|
作者
Cao, Ya [1 ]
Jiang, Lianxiang [1 ]
Zhang, Yan [2 ]
Yao, Weidong [1 ]
Chen, Yongquan [1 ]
Dai, Zeping [1 ]
机构
[1] Wannan Med Coll, Affiliated Hosp 1, Dept Anaesthesia, 2 Zheshan West Rd, Wuhu, Anhui, Peoples R China
[2] Tongling Peoples Hosp, Dept Anaesthesia, Tongling, Anhui, Peoples R China
关键词
Video laryngoscope; Tracheal intubation; Tube shaping; RAPID-SEQUENCE INTUBATION; OROTRACHEAL INTUBATION; GLOTTIC VISUALIZATION; EMERGENCY; SUCCESS; MAC;
D O I
10.1007/s10877-022-00806-4
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Although video laryngoscopy solves the problem of glottis exposure, it is difficult to deliver the tube to the glottic opening when the tracheal tube is unevenly shaped. This study aimed to compare the effects of different tube shapes on the first-pass success (FPS) rate in patients undergoing video laryngoscopy-assisted tracheal intubation. Three hundred patients above 18 years of age who underwent general anaesthesia and required endotracheal intubation were included in the study. The participants were randomly allocated to three groups with 100 participants in each group as follows: Group A, video laryngoscopes with a self-equipped stylet are used for tube preshaping; Group B: curvature of the video laryngoscope blade is modelled for tube preshaping; Group C: tube preshaping angle is consistent with the video laryngoscope blade, and the bending point is set 1 cm above the tracheal tube cuff. The primary outcome was FPS rates. The secondary outcomes included time to tracheal intubation, haemodynamic responses and adverse events. No significant differences in patient characteristics or airway assessments were noted (P > 0.05). Compared with Groups A, Group B and Group C exhibited a higher FPS rate (68% vs. 86% vs. 92%; P < 0.001). However, there is no significant difference in FPS rate between Group B and Group C (P > 0.05). And the time to tracheal intubation in Group C was significantly less than that in Group A and Group B (22.21 +/- 4.01 vs. 19.92 +/- 4.11 vs. 17.71 +/- 3.47; P < 0.001). The straight-to-cuff stylet preshape angulation of curvature of the blade could provide a higher FPS rate and shorter time to tracheal intubation during video laryngoscopy-assisted endotracheal intubation. Trial registration: Chinese Clinical Trial Registry, ChiCTR1900026019.
引用
收藏
页码:1629 / 1634
页数:6
相关论文
共 50 条
  • [31] Intubation using VieScope vs. Video laryngoscopy in full personal protective equipment – a randomized, controlled simulation trial
    Hannes Ecker
    Simone Kolvenbach
    Holger Herff
    Wolfgang A. Wetsch
    BMC Anesthesiology, 21
  • [32] Tracheal intubation with the glidesSope® videolaryngoscope, using a “J” shaped endotracheal tube
    Stephen O. Bader
    James W. Heitz
    Paul B. Audu
    Canadian Journal of Anesthesia, 2006, 53 : 634 - 635
  • [33] Effects of bevel direction of endotracheal tube on the postoperative sore throat when performing fiberoptic-guided tracheal intubation: A randomized controlled trial
    Kim, Hyunjee
    Kim, Jeong Eon
    Yang, Woo Seok
    Hong, Seong Wook
    Jung, Hoon
    MEDICINE, 2022, 101 (35) : E30372
  • [34] Comparison between Glidescope, Airtraq and Macintosh laryngoscopy for emergency endotracheal intubation in intensive care unit: Randomized controlled trial
    Abdelgalel, Essam F.
    Mowafy, Sherif M. S.
    EGYPTIAN JOURNAL OF ANAESTHESIA, 2018, 34 (04) : 123 - 128
  • [35] Optimal size and length of the endotracheal tube for tracheal intubation via supraglottic airway devices
    Xue, Fu S.
    Xiong, Jun
    Yuan, Yu J.
    Wang, Qiang
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2010, 57 (06): : 624 - 625
  • [36] Videolaryngoscope for Teaching Neonatal Endotracheal Intubation: A Randomized Controlled Trial
    Moussa, Ahmed
    Luangxay, Yvon
    Tremblay, Sophie
    Lavoie, Julie
    Aube, Guylaine
    Savoie, Eve
    Lachance, Christian
    PEDIATRICS, 2016, 137 (03)
  • [37] Optimal size and length of the endotracheal tube for tracheal intubation via supraglottic airway devices
    Fu S. Xue
    Jun Xiong
    Yu J. Yuan
    Qiang Wang
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2010, 57 : 624 - 625
  • [38] Is there an optimal place to hold the endotracheal tube during direct laryngoscopy for patients undergoing surgery under general anesthesia? Protocol for a randomized controlled trial
    Sahoo, Manisha
    Tripathy, Swagata
    Mishra, Nitasha
    TRIALS, 2021, 22 (01)
  • [39] Comparative Evaluation of Linscope and King Vision Video Laryngoscopes in Tracheal Intubation: A Randomized Controlled Trial
    Luqman, Mohd
    Ahmed, S. Moied
    Shaharyar, Amal
    Mannan, Raihan
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (03)
  • [40] Is there an optimal place to hold the endotracheal tube during direct laryngoscopy for patients undergoing surgery under general anesthesia? Protocol for a randomized controlled trial
    Manisha Sahoo
    Swagata Tripathy
    Nitasha Mishra
    Trials, 22