Cone Ratios in Myopia and Emmetropia: A Pilot Study

被引:8
|
作者
Zhou, Nanyu [1 ,2 ]
Atchison, David A. [1 ,2 ]
Zele, Andrew J. [1 ,2 ]
Brown, Brian [1 ,2 ]
Schmid, Katrina L. [1 ,2 ]
机构
[1] Queensland Univ Technol, Sch Optometry & Vis Sci, Kelvin Grove, Qld 4059, Australia
[2] Queensland Univ Technol, Inst Hlth & Biomed Innovat, Kelvin Grove, Qld 4059, Australia
关键词
color vision; cone ratios; emmetropia; long wavelength-sensitive cone; middle wavelength-sensitive cone; multifocal visual evoked potential; myopia; ISOLATING STIMULI; RELATIVE NUMBERS; VISUAL PIGMENTS; HUMAN RETINA; ELECTRORETINOGRAM; TRICHROMATS; DICHROMATS; MONITOR; FOVEA; EYE;
D O I
10.1097/OPX.0000000000000450
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. There is a suggestion that the long wavelength-sensitive (LWS)-to-middle wavelength-sensitive (MWS) cone ratio in the retina is associated with myopia. The aim was to measure the LWS/MWS amplitude modulation ratio, an estimate of the LWS/MWS cone ratio, in young adult emmetropes and myopes. Methods. Multifocal visual evoked potentials were measured when the LWS and MWS cone systems were excited separately using the method of silent substitution. The 30 young adult participants (22 to 33 years) included 10 emmetropes (mean [+/- SD] refraction, +0.3 [+/- 0.4] diopters [D]) and 20 myopes (mean [TSD] refraction, -3.4 [+/- 1.7] D). Results. The LWS/MWS amplitude modulation ratios ranged from 0.56 to 1.80 in the central 3- to 13-degree diameter ring and from 0.94 to 1.91 in the peripheral 13- to 30-degree diameter ring. Within the central ring, the mean (+/- SD) ratios were 1.20 (+/- 0.26) and 1.20 (+/- 0.33) for the emmetropic and the myopic groups, respectively. For the peripheral ring, the mean (+/- SD) ratios were 1.48 (+/- 0.27) and 1.30 (+/- 0.27), respectively. There were no significant differences in the ratios between the emmetropic and myopic groups for either the central (p = 0.99) or peripheral (p = 0.08) rings. For the latter, more myopic refractive error was associated with lower LWS/MWS amplitude modulation ratio; the refraction explained 16% (p = 0.02) of variation in ratio. Conclusions. The relationship between the LWS/MWS amplitude modulation ratios and refraction at 13 to 30 degrees indicates that a large longitudinal study of changes in refraction in persons with known cone ratio is required to determine if a low LWS/MWS cone ratio is associated with myopia development.
引用
收藏
页码:E1 / E5
页数:5
相关论文
共 50 条
  • [21] ASPECTS OF TONIC ACCOMMODATION IN EMMETROPIA AND LATE-ONSET MYOPIA
    BULLIMORE, MA
    GILMARTIN, B
    [J]. AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1987, 64 (07): : 499 - 503
  • [22] Ciliary Muscle Dimension Changes With Accommodation Vary in Myopia and Emmetropia
    Kaphle, Dinesh
    Schmid, Katrina L.
    Davies, Leon N.
    Suheimat, Marwan
    Atchison, David A.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (06)
  • [23] Relative peripheral retractive error in adult myopia and emmetropia.
    Love, J
    Gilmartin, B
    Dunne, MCM
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S302 - S302
  • [24] Effect of eye rubbing on corneal biomechanical properties in myopia and emmetropia
    Li, Xia
    Wei, Anji
    Yang, Yujing
    Hong, Jiaxu
    Xu, Jianjiang
    [J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [25] MYOPIA AND THE TREND TOWARDS EMMETROPIA IN NEW BORN PREMATURE BABIES
    LINFIELD, PB
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 1353 - 1353
  • [26] The differebce in accommodative response and accommodative vergence between the subjects with emmetropia, stable myopia, and progressive myopia
    Xu, D
    Lu, F
    Qu, J
    Jiang, B
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U997 - U997
  • [27] A Comparative Study of Corneal Endothelial Cell Count and Central Corneal Thickness in Emmetropia and Axial Myopia
    Panjwani, Vandana
    Daigavane, Sachin
    [J]. JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2020, 9 (44): : 3300 - 3304
  • [28] More Irregular Eye Shape in Low Myopia Than in Emmetropia
    Tabernero, Juan
    Schaeffel, Frank
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (09) : 4516 - 4522
  • [29] Shape discrimination thresholds among subjects with emmetropia and corrected myopia
    Rajeev, Narayanan
    Tan, Eddie
    Liyana, Raja
    Metha, Andrew
    [J]. CLINICAL AND EXPERIMENTAL OPTOMETRY, 2015, 98 (04) : 353 - 358
  • [30] The effect of target luminance upon the micro fluctuations of accommodation in emmetropia and myopia
    Seidel, D
    Day, M
    Strang, NC
    Gray, LS
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46