ZIF-8 Nanoparticles Based Electrochemical Sensor for Non-Enzymatic Creatinine Detection

被引:15
|
作者
Chakraborty, Titisha [1 ]
Das, Munmun [1 ]
Lin, Chan-Yu [2 ]
Su, Yen [1 ]
Yuan, Bing [1 ]
Kao, Chyuan-Haur [1 ,2 ,3 ,4 ]
机构
[1] Chang Gung Univ, Dept Elect Engn, 259 Wenhwa 1st Rd, Taoyuan 33302, Taiwan
[2] Chang Gung Mem Hosp, Dept Nephrol, Kidney Res Ctr, 5 Fuxing St, Taoyuan 33302, Taiwan
[3] Ming Chi Univ Technol, Dept Elect Engn, 284 Gungjuan Rd, New Taipei 24301, Taiwan
[4] Chang Gung Univ, Ctr Green Technol, 259 Wenhwa 1st Rd, Taoyuan 33302, Taiwan
关键词
ZIF-8; NPs; non-enzymatic; creatinine; sensor; creatinine-Zn composite; POTENTIOMETRIC SENSORS; SERUM CREATININE;
D O I
10.3390/membranes12020159
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
There is a consistent demand for developing highly sensitive, stable, cost-effective, and easy-to-fabricate creatinine sensors as creatinine is a reliable indicator of kidney and muscle-related disorders. Herein, we reported a highly sensitive and selective non-enzymatic electrochemical creatinine sensor via modifying poly(3,4 ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) coated indium tin oxide (ITO) substrate by zeolitic imidazolate framework-8 nanoparticles (ZIF-8 NPs). The topography, crystallinity, and composition of the sensing electrode were characterized by field emission scanning electron microscopy (FESEM), atomic force microscopy (AFM), X-ray diffraction (XRD), and X-ray photoelectron spectroscopy (XPS). The peroxidase-like activity of ZIF-8 nanoparticles enabled it to detect creatinine forming a zinc-creatinine composite. The electrochemical behavior and sensing performance were evaluated by amperometric and impedimetric analysis. The sensor obtained a sufficiently low limit of detection (LOD) of 30 mu M in a clinically acceptable linear range (0.05 mM-2.5 mM). The interference study demonstrated high selectivity of the sensor for creatinine concerning other similar biomolecules. The sensing performance of the creatinine sensor was verified in the actual human serum, which showed excellent recovery rates. Hence, the magnificent performance of ZIF-8 based non-enzymatic creatinine sensor validated it as a responsible entity for other complicated renal markers detection.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] An alkaline ferrocyanide non-enzymatic electrochemical sensor for creatinine detection
    Bajpai, Sonal
    Akien, Geoffrey R.
    Toghill, Kathryn E.
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2024, 158
  • [2] Non-enzymatic disposable paper sensor for electrochemical detection of creatinine
    Manikandan, Ramalingam
    Yoon, Jang-Hee
    Lee, Jaewon
    Chang, Seung-Cheol
    [J]. MICROCHEMICAL JOURNAL, 2024, 204
  • [3] Fabrication of a disposable non-enzymatic electrochemical creatinine sensor
    Raveendran, Jeethu
    Resmi, P. E.
    Ramachandran, T.
    Nair, Bipin G.
    Babu, T. G. Satheesh
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2017, 243 : 589 - 595
  • [4] An electrochemical sensor based on the modification of platinum nanoparticles and ZIF-8 membrane for the detection of ascorbic acid
    Ma, Ya
    Zhang, Yunlong
    Wang, Lishi
    [J]. TALANTA, 2021, 226
  • [5] ZIF-8 derived Ni(OH)2 hollow nanocages for non-enzymatic glucose electrochemical sensing
    Xu, Feng
    Hu, Kelin
    Wang, Siyuan
    Chen, Xu
    Xu, Rujuan
    Xiong, Xiaoli
    Yuan, Xin
    Zhang, Mei
    Huang, Ke
    [J]. JOURNAL OF MATERIALS SCIENCE, 2022, 57 (39) : 18589 - 18600
  • [6] Non-Enzymatic Disposable Paper Sensor for One-Step Electrochemical Detection of Creatinine
    Department of Cogno-Mechatronics Engineering, College of Nanoscience and Nanotechnology, Pusan National University, Busan
    46241, Korea, Republic of
    不详
    46241, Korea, Republic of
    不详
    46742, Korea, Republic of
    不详
    46241, Korea, Republic of
    [J].
  • [7] ZIF-8 derived Ni(OH)2 hollow nanocages for non-enzymatic glucose electrochemical sensing
    Feng Xu
    Kelin Hu
    Siyuan Wang
    Xu Chen
    Rujuan Xu
    Xiaoli Xiong
    Xin Yuan
    Mei Zhang
    Ke Huang
    [J]. Journal of Materials Science, 2022, 57 : 18589 - 18600
  • [8] Non-Enzymatic Electrochemical Detection of Urine Creatinine Using Cobalt-Gold Bimetallic Nanoparticles
    Meera, R.
    Neena, P. K.
    Pradeep, Aarathi
    Nair, Bipin G.
    Vasu, Suneesh Punathil
    Babu, T. G. Satheesh
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2024, 171 (06)
  • [9] Non-enzymatic electrochemical sensor based on ZnO nanoparticles/porous graphene for the detection of hypoxanthine in pork meat
    Le, N. T. H.
    Viet, N. X.
    Anh, N. V.
    Bach, T. N.
    Thu, P. T.
    Ngoc, N. T.
    Manh, D. H.
    Ky, V. H.
    Lam, V. D.
    Kodelov, V.
    Von Gratowski, S.
    Binh, N. H.
    Anh, T. X.
    [J]. AIP ADVANCES, 2024, 14 (02)
  • [10] A New Non-Enzymatic Amperometric Sensor Based on Nickel Decorated ZIF-8 Derived Carbon Nanoframe for the Glucose Determination in Blood Samples
    Sukhrobov, Parviz
    Numonov, Sodik
    Mamat, Xamxikamar
    Li, Yongtao
    Wagberg, Thomas
    Hu, Guangzhi
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (07): : 6550 - 6564