An alkaline ferrocyanide non-enzymatic electrochemical sensor for creatinine detection

被引:3
|
作者
Bajpai, Sonal [1 ]
Akien, Geoffrey R. [1 ]
Toghill, Kathryn E. [1 ]
机构
[1] Univ Lancaster, Dept Chem, Lancaster LA1 4YB, England
基金
英国工程与自然科学研究理事会;
关键词
Creatinine; Electrocatalysis; Ferricyanide; Screen printed carbon electrode; Chronic kidney disease; Non-enzymatic; OXIDATION; NANOCOMPOSITE; METHYLGUANIDINE; FERRICYANIDE; COMPLEXES; AMINES; OXIDE;
D O I
10.1016/j.elecom.2023.107624
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Creatinine is a useful metabolite for the evaluation of Chronic Kidney Disease (CKD). Creatinine concentrations in urine outside of the healthy range of 4 to 15 mM may indicate CKD and other kidney conditions. Early detection and monitoring can provide lifesaving intervention, and as such there is a need to develop rapid, cheap and selective electrochemical creatinine sensors. A simple non-enzymatic creatinine sensing platform enabled by the electrocatalytic response of the metabolite to ferricyanide in alkaline conditions is presented. Studies were made on unmodified glassy carbon (GCE) and screen printed carbon electrodes (SPCE), both giving sensitivity of 21 +/- 5 mu A mM-1 cm-2 and limit of detection of ca. 60 mu M.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Non-enzymatic disposable paper sensor for electrochemical detection of creatinine
    Manikandan, Ramalingam
    Yoon, Jang-Hee
    Lee, Jaewon
    Chang, Seung-Cheol
    [J]. MICROCHEMICAL JOURNAL, 2024, 204
  • [2] Fabrication of a disposable non-enzymatic electrochemical creatinine sensor
    Raveendran, Jeethu
    Resmi, P. E.
    Ramachandran, T.
    Nair, Bipin G.
    Babu, T. G. Satheesh
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2017, 243 : 589 - 595
  • [3] Non-Enzymatic Disposable Paper Sensor for One-Step Electrochemical Detection of Creatinine
    Department of Cogno-Mechatronics Engineering, College of Nanoscience and Nanotechnology, Pusan National University, Busan
    46241, Korea, Republic of
    不详
    46241, Korea, Republic of
    不详
    46742, Korea, Republic of
    不详
    46241, Korea, Republic of
    [J].
  • [4] ZIF-8 Nanoparticles Based Electrochemical Sensor for Non-Enzymatic Creatinine Detection
    Chakraborty, Titisha
    Das, Munmun
    Lin, Chan-Yu
    Su, Yen
    Yuan, Bing
    Kao, Chyuan-Haur
    [J]. MEMBRANES, 2022, 12 (02)
  • [5] NON-ENZYMATIC ELECTROCHEMICAL GLUCOSE DETECTION
    TINDALL, CE
    MCMULLEN, JK
    MORROW, DJ
    [J]. IRISH JOURNAL OF MEDICAL SCIENCE, 1985, 154 (07) : 288 - 288
  • [6] Non-enzymatic electrochemical CuO nanoflowers sensor for hydrogen peroxide detection
    Song, Min-Jung
    Hwang, Sung Woo
    Whang, Dongmok
    [J]. TALANTA, 2010, 80 (05) : 1648 - 1652
  • [7] Review-Enzymatic and Non-Enzymatic Electrochemical Sensor for Lactate Detection in Human Biofluids
    Md Shakhih, Muhammad Faiz
    Rosslan, Anis Suzziani
    Noor, Anas Mohd
    Ramanathan, Santheraleka
    Lazim, Azwan Mat
    Wahab, Asnida Abdul
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (06)
  • [8] A review of recent advances in non-enzymatic electrochemical creatinine biosensing
    Kumar, R. K. Rakesh
    Shaikh, Muhammad Omar
    Chuang, Cheng-Hsin
    [J]. ANALYTICA CHIMICA ACTA, 2021, 1183
  • [9] Flexible electrochemical sensor for highly sensitive and selective non-enzymatic detection of creatinine via electrodeposited copper over polymelamine formaldehyde
    Mehta, Daisy
    Kafle, Alankar
    Nagaiah, Tharamani C.
    [J]. JOURNAL OF MATERIALS CHEMISTRY B, 2023, 11 (46) : 11103 - 11109
  • [10] A non-enzymatic electrochemical sensor based on polyaniline/borophene nanocomposites for dopamine detection
    Baytemir, Gulsen
    [J]. APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2023, 129 (02):