Ppb-level gas detection using on-beam quartz-enhanced photoacoustic spectroscopy based on a 28 kHz tuning fork

被引:74
|
作者
Lin, Haoyang [1 ,2 ]
Zheng, Huadan [1 ,2 ]
Montano, Baiyang Antonio Zhou [1 ,2 ]
Wu, Hongpeng [3 ]
Giglio, Marilena [4 ]
Sampaolo, Angelo [4 ]
Patimisco, Pietro [4 ]
Zhu, Wenguo [1 ,2 ]
Zhong, Yongchun [1 ,2 ]
Dong, Lei [3 ]
Kan, Ruifeng [5 ]
Yu, Jianhui [1 ,2 ]
Spagnolo, Vincenzo [4 ]
机构
[1] Jinan Univ, Guangdong Prov Key Lab Opt Fiber Sensing & Commun, Guangzhou 510632, Peoples R China
[2] Jinan Univ, Dept Optoelect Engn, Guangzhou 510632, Peoples R China
[3] Shanxi Univ, Inst Laser Spect, State Key Lab Quantum Opt & Quantum Opt Devices, Taiyuan 030006, Peoples R China
[4] Univ & Politecn Bari, Dipartimento Interateneo Fis, PolySense Lab, CNR IFN, Via Amendola 173, I-70126 Bari, Italy
[5] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Key Lab Environm Opt & Technol, Hefei, Peoples R China
来源
PHOTOACOUSTICS | 2022年 / 25卷
基金
中国国家自然科学基金;
关键词
Optical sensing; Photoacoustic spectroscopy; Quartz tuning fork; Quartz enhanced photoacoustic spectroscopy; QEPAS SENSOR; RESONATORS;
D O I
10.1016/j.pacs.2021.100321
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In this paper, an on-beam quartz-enhanced photoacoustic spectroscopy (QEPAS) sensor based on a custom quartz tuning fork (QTF) acting as a photoacoustic transducer, was realized and tested. The QTF is characterized by a resonance frequency of 28 kHz, similar to 15% lower than that of a commercially available 32.7 kHz standard QTF. One-dimensional acoustic micro resonator (AmR) was designed and optimized by using stainless-steel capillaries. The 28 kHz QTF and AmRs are assembled in on-beam QEPAS configuration. The AmR geometrical parameters have been optimized in terms of length and internal diameter. The laser beam focus position and the AmR coupling distance were also adjusted to maximize the coupling efficiency. For comparison, QEPAS on-beam configurations based on a standard QTF and on the 28 kHz QTF were compared in terms of H2O and CO2 detection sensitivity. In order to better characterize the performance of the system, H2O, C2H2 and CO2 were detected for a long time and the long-term stability was analyzed by an Allan variance analysis. With the integration time of 1 s, the detection limits for H2O, C2H2 and CO2 are 1.2 ppm, 28.8 ppb and 2.4 ppm, respectively. The detection limits for H2O, C2H2 and CO2 can be further improved to 325 ppb, 10.3 ppb and 318 ppb by increasing the integration time to 521 s, 183 s and 116 s
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Gas detection with evanescent-wave quartz-enhanced photoacoustic spectroscopy
    Cao, Yingchun
    Jin, Wei
    Ho, Hoi Lut
    THIRD ASIA PACIFIC OPTICAL SENSORS CONFERENCE, 2012, 8351
  • [32] A portable gas sensor for sensitive CO detection based on quartz-enhanced photoacoustic spectroscopy
    He, Ying
    Ma, Yufei
    Tong, Yao
    Yu, Xin
    Tittel, Frank K.
    OPTICS AND LASER TECHNOLOGY, 2019, 115 : 129 - 133
  • [33] Quartz-enhanced photoacoustic sensor for ethylene detection implementing optimized custom tuning fork-based spectrophone
    Giglio, Marilena
    Elefante, Arianna
    Patimisco, Pietro
    Sampaolo, Angelo
    Sgobba, Fabrizio
    Rossmadl, Hubert
    Mackowiak, Verena
    Wu, Hongpeng
    Tittel, Frank K.
    Dong, Lei
    Spagnolo, Vincenzo
    OPTICS EXPRESS, 2019, 27 (04) : 4271 - 4280
  • [34] Research progress of quartz-enhanced photoacoustic spectroscopy based gas sensing
    Ma Yu-Fei
    ACTA PHYSICA SINICA, 2021, 70 (16)
  • [35] Quartz-enhanced photoacoustic spectroscopy for hydrocarbon trace gas detection and petroleum exploration
    Sampaolo, Angelo
    Menduni, Giansergio
    Patimisco, Pietro
    Giglio, Marilena
    Passaro, Vittorio M. N.
    Dong, Lei
    Wu, Hongpeng
    Tittel, Frank K.
    Spagnolo, Vincenzo
    FUEL, 2020, 277
  • [36] Impact of humidity on quartz-enhanced photoacoustic spectroscopy based detection of HCN
    Kosterev, A. A.
    Mosely, T. S.
    Tittel, F. K.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2006, 85 (2-3): : 295 - 300
  • [37] Impact of humidity on quartz-enhanced photoacoustic spectroscopy based detection of HCN
    A.A. Kosterev
    T.S. Mosely
    F.K. Tittel
    Applied Physics B, 2006, 85 : 295 - 300
  • [38] Trace Gas Detection System Based on All-Optical Quartz-Enhanced Photoacoustic Spectroscopy
    Lin, Cheng
    Liao, Yu
    Fang, Fei
    APPLIED SPECTROSCOPY, 2019, 73 (11) : 1327 - 1333
  • [39] Single-tube on beam quartz-enhanced photoacoustic spectrophones exploiting a custom quartz tuning fork operating in the overtone mode
    Giglio, Marilena
    Sampaolo, Angelo
    Patimisco, Pietro
    Zheng, Huadan
    Wu, Hongpeng
    Dong, Lei
    Tittel, Frank K.
    Spagnolo, Vincenzo
    QUANTUM SENSING AND NANO ELECTRONICS AND PHOTONICS XIV, 2017, 10111
  • [40] Improved T-shaped quartz tuning fork with isosceles-trapezoidal grooves optimized for quartz-enhanced photoacoustic spectroscopy
    Fang, Feihu
    Wang, Runqiu
    Shao, Dongfang
    Wang, Yi
    Tao, Yilue
    Lin, Shengshou
    Ma, Yufei
    Liang, Jinxing
    PHOTOACOUSTICS, 2025, 41