Deep Learning Approaches for Automatic Quality Assurance of Magnetic Resonance Images Using ACR Phantom

被引:0
|
作者
Torfeh, Tarraf [1 ]
Aouadi, Souha [1 ]
Yoganathan, S. A. [1 ]
Paloor, Satheesh [1 ]
Hammoud, Rabih [1 ]
Al-Hammadi, Noora [1 ]
机构
[1] Hamad Med Corp, Natl Ctr Canc Care & Res NCCCR, Dept Radiat Oncol, Doha, Qatar
关键词
MRI; Deep learning; Quality control;
D O I
10.1186/s12880-023-01157-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundIn recent years, there has been a growing trend towards utilizing Artificial Intelligence (AI) and machine learning techniques in medical imaging, including for the purpose of automating quality assurance. In this research, we aimed to develop and evaluate various deep learning-based approaches for automatic quality assurance of Magnetic Resonance (MR) images using the American College of Radiology (ACR) standards.MethodsThe study involved the development, optimization, and testing of custom convolutional neural network (CNN) models. Additionally, popular pre-trained models such as VGG16, VGG19, ResNet50, InceptionV3, EfficientNetB0, and EfficientNetB5 were trained and tested. The use of pre-trained models, particularly those trained on the ImageNet dataset, for transfer learning was also explored. Two-class classification models were employed for assessing spatial resolution and geometric distortion, while an approach classifying the image into 10 classes representing the number of visible spokes was used for the low contrast.ResultsOur results showed that deep learning-based methods can be effectively used for MR image quality assurance and can improve the performance of these models. The low contrast test was one of the most challenging tests within the ACR phantom.ConclusionsOverall, for geometric distortion and spatial resolution, all of the deep learning models tested produced prediction accuracy of 80% or higher. The study also revealed that training the models from scratch performed slightly better compared to transfer learning. For the low contrast, our investigation emphasized the adaptability and potential of deep learning models. The custom CNN models excelled in predicting the number of visible spokes, achieving commendable accuracy, recall, precision, and F1 scores.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Deep Learning Approaches for Automatic Quality Assurance of Magnetic Resonance Images Using ACR Phantom
    Tarraf Torfeh
    Souha Aouadi
    SA Yoganathan
    Satheesh Paloor
    Rabih Hammoud
    Noora Al-Hammadi
    [J]. BMC Medical Imaging, 23
  • [2] Software development for quality assurance using ACR SPECT phantom
    Choi, Jae Min
    Nam, Ki Pyo
    Kim, Jae Seung
    Ryu, Jin-Sook
    Moon, Dae Hyuk
    Oh, Jungsu
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [3] An open source automatic quality assurance (OSAQA) tool for the ACR MRI phantom
    Jidi Sun
    Michael Barnes
    Jason Dowling
    Fred Menk
    Peter Stanwell
    Peter B. Greer
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2015, 38 : 39 - 46
  • [4] An open source automatic quality assurance (OSAQA) tool for the ACR MRI phantom
    Sun, Jidi
    Barnes, Michael
    Dowling, Jason
    Menk, Fred
    Stanwell, Peter
    Greer, Peter B.
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2015, 38 (01) : 39 - 46
  • [5] Automatic Analysis of ACR Phantom Images in MRI
    Ben Alaya, Ines
    Mars, Mokhtar
    [J]. CURRENT MEDICAL IMAGING, 2020, 16 (07) : 892 - 901
  • [6] Automatic segmentation of the temporomandibular joint disc on magnetic resonance images using a deep learning technique
    Nozawa, Michihito
    Ito, Hirokazu
    Ariji, Yoshiko
    Fukuda, Motoki
    Igarashi, Chinami
    Nishiyama, Masako
    Ogi, Nobumi
    Katsumata, Akitoshi
    Kobayashi, Kaoru
    Ariji, Eiichiro
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2022, 51 (01)
  • [7] MRI quality assurance using the ACR phantom in a multi-unit imaging center
    Ihalainen, Toni M.
    Lonnroth, Nadja T.
    Peltonen, Juha I.
    Uusi-Simola, Jouni K.
    Timonen, Marjut H.
    Kuusela, Linda J.
    Savolainen, Sauli E.
    Sipila, Outi E.
    [J]. ACTA ONCOLOGICA, 2011, 50 (06) : 966 - 972
  • [8] Quality assurance of clinical MRI scanners using ACR MRI phantom: Preliminary results
    Chen, CC
    Wan, YL
    Wai, YY
    Liu, HL
    [J]. JOURNAL OF DIGITAL IMAGING, 2004, 17 (04) : 279 - 284
  • [9] Quality Assurance of Clinical MRI Scanners Using ACR MRI Phantom: Preliminary Results
    Chien-Chuan Chen
    Yung-Liang Wan
    Yau-Yau Wai
    Ho-Ling Liu
    [J]. Journal of Digital Imaging, 2004, 17 : 279 - 284
  • [10] Machine and deep learning approaches for alzheimer disease detection using magnetic resonance images: An updated review
    Menagadevi, M.
    Devaraj, Somasundaram
    Madian, Nirmala
    Thiyagarajan, D.
    [J]. MEASUREMENT, 2024, 226