Application of Raman spectroscopy during pharmaceutical process development for determination of critical quality attributes in Protein A chromatography

被引:3
|
作者
Chen, Jingyi [1 ,2 ]
Wang, Jiarui [1 ]
Hess, Rudger [1 ]
Wang, Gang [1 ]
Studts, Joey [1 ]
Franzreb, Matthias [2 ]
机构
[1] Boehringer Ingelheim Pharm GmbH Co KG, Biberach, Germany
[2] Karlsruhe Inst Technol, Inst Funct Interfaces, D-76344 Eggenstein Leopoldshafen, Germany
关键词
Therapeutic antibody; Process analytical technology; Process robustness; Machine learning; In-line monitoring; FRAGMENTATION;
D O I
10.1016/j.chroma.2024.464721
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Raman spectroscopy is considered a Process Analytical Technology (PAT) tool in biopharmaceutical downstream processes. In the past decade, researchers have shown Raman spectroscopy's feasibility in determining Critical Quality Attributes (CQAs) in bioprocessing. This study verifies the feasibility of implementing a Raman-based PAT tool in Protein A chromatography as a CQA monitoring technique, for the purpose of accelerating process development and achieving real-time release in manufacturing. A system connecting Raman to a Tecan liquid handling station enables high-throughput model calibration. One calibration experiment collects Raman spectra of 183 samples with 8 CQAs within 25 h. After applying Butterworth high-pass filters and k-nearest neighbor (KNN) regression for model training, the model showed high predictive accuracy for fragments (Q2 = 0.965) and strong predictability for target protein concentration, aggregates, as well as charge variants (Q2 >= 0.922). The model's robustness was confirmed by varying the elution pH, load density, and residence time using 19 external validation preparative Protein A chromatography runs. The model can deliver elution profiles of multiple CQAs within a set point +/- 0.3 pH range. The CQA readouts were presented as continuous chromatograms with a resolution of every 28 s for enhanced process understanding. In external validation datasets, the model maintained strong predictability especially for target protein concentration (Q2 = 0.956) and basic charge variants (Q2 = 0.943), except for overpredicted HCP (Q2 = 0.539). This study demonstrates a rapid, effective method for implementing Raman spectroscopy for in-line CQA monitoring in process development and biomanufacturing, eliminating the need for labor-intensive sample pooling and handling.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Quality-by-Design III: Application of Near-Infrared Spectroscopy to Monitor Roller Compaction In-process and Product Quality Attributes of Immediate Release Tablets
    Kona, Ravikanth
    Fahmy, Raafat M.
    Claycamp, Gregg
    Polli, James E.
    Martinez, Marilyn
    Hoag, Stephen W.
    AAPS PHARMSCITECH, 2015, 16 (01): : 202 - 216
  • [42] Development and application of a universal method for quantitation of anionic constituents in active pharmaceutical ingredients during early development using suppressed conductivity ion chromatography
    Cassidy, SA
    Demarest, CW
    Wright, PB
    Zimmerman, JB
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (02) : 255 - 264
  • [43] Application of stealth nanobeacon for traceability assurance in pharmaceutical tablets via surface-enhanced Raman scattering during the tablet coating process
    Yasunaga, Toshiya
    Fukuoka, Takao
    Yamaguchi, Akinobu
    Ogawa, Noriko
    Yamamoto, Hiromitsu
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2024, 666
  • [44] Application of Deep-Learning Algorithm Driven Intelligent Raman Spectroscopy Methodology to Quality Control in the Manufacturing Process of Guanxinning Tablets
    Tao, Yi
    Bao, Jiaqi
    Liu, Qing
    Liu, Li
    Zhu, Jieqiang
    MOLECULES, 2022, 27 (20):
  • [45] APPLICATION OF THE FMEA DURING THE PRODUCT DEVELOPMENT PROCESS - DEPENDENCIES BETWEEN LEVEL OF INFORMATION AND QUALITY OF RESULT
    Wuertenberger, J.
    Kloberdanz, H.
    Lotz, J.
    von Ahsen, A.
    DS 77: PROCEEDINGS OF THE DESIGN 2014 13TH INTERNATIONAL DESIGN CONFERENCE, VOLS 1-3, 2014, : 417 - 426
  • [46] Using surface-enhanced Raman spectroscopy combined with chemometrics for black tea quality assessment during its fermentation process
    Luo, Xuelun
    Gouda, Mostafa
    Perumal, Anand Babu
    Huang, Zhenxiong
    Lin, Lei
    Tang, Yu
    Sanaeifar, Alireza
    He, Yong
    Li, Xiaoli
    Dong, Chunwang
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 373
  • [47] Development and Validation of RP-HPLC Method for Determination of Famotidine and its Application in Quality Control of Different Pharmaceutical Dosage Forms
    Ul Hassan, Syed Saeed
    Ahmad, Irshad
    Ayub, Muhammad
    Ishtiaq, Saiqa
    Hayat, Muhammad Munawar
    Khalid, Nayab
    Ansari, Muhammad Tayyab
    Uzair, Muhammad
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2013, 35 (03): : 809 - 814
  • [48] Development of Electronic Nose and Near Infrared Spectroscopy Analysis Techniques to Monitor the Critical Time in SSF Process of Feed Protein
    Jiang, Hui
    Chen, Quansheng
    SENSORS, 2014, 14 (10) : 19441 - 19456
  • [49] Application of quality by design principles to the development and technology transfer of a major process improvement for the manufacture of a recombinant protein
    Looby, Mairead
    Ibarra, Neysi
    Pierce, James J.
    Buckley, Kevin
    O'Donovan, Eimear
    Heenan, Mary
    Moran, Enda
    Farid, Suzanne S.
    Baganz, Frank
    BIOTECHNOLOGY PROGRESS, 2011, 27 (06) : 1718 - 1729
  • [50] Design of Experiments-Based Monitoring of Critical Quality Attributes for the Spray-Drying Process of Insulin by NIR Spectroscopy (vol 13, pg 747, 2012)
    Maltesen, Morten Jonas
    van de Weert, Marco
    Grohganz, Holger
    AAPS PHARMSCITECH, 2013, 14 (02): : 901 - 901