摘要
Retention time is one of the most important parameters that has been widely used to demonstrate the separation results obtained from liquid chromatography (LC) platforms. However, retention time can shift when samples are tested with different instruments and laboratories, which hinders the identification process of analytes when comparing data collected from different LC systems. To address this problem, hydrophobicity index was introduced for retention time normalization of the glycopeptides separated by reversed-phase LC (RPLC). Tandem MS was used for the detection and identification of glycopeptides. In addition, the influence of different types of glycans on the hydrophobicity of peptide backbones was studied by comparing the retention time of glycopeptides with their non-glycosylated counterparts. The hydrophobicity of tryptic digested glycopeptides derived from model glycoproteins, including bovine fetuin, & alpha;1-acid glycoprotein, and haptoglobin from human plasma, were evaluated based on the hydrophobicity index of the standard peptides from a peptide retention time calibration mixture. The reduction of hydrophobicity of multiple peptide backbones was observed due to the hydrophilic glycan structures. By comparing the hydrophobicity index of glycopeptides collected from different time and instruments, the day-to-day and lab-to-lab comparisons suggested high reliability and reproducibility of this approach. The RSD% of hydrophobicity index from inter-lab experiments was 1.2%, while the RSD% of retention time was 5.1%. Then, the applications of this method were demonstrated on complex glycopeptide samples extracted from human blood serum. The hydrophobicity index can be applied to address the retention time shift when using different instruments, thereby boosting confidence of the characterization of glycopeptides.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] High-pH mobile phase in reversed-phase liquid chromatography-tandem mass spectrometry to improve the separation efficiency of aminoglycoside isomers
    Yuta Nakano
    Hiroshi Sakamaki
    Yuiko Tasaki-Handa
    Shingo Saito
    [J]. Analytical Sciences, 2024, 40 : 375 - 384
  • [42] High-pH mobile phase in reversed-phase liquid chromatography-tandem mass spectrometry to improve the separation efficiency of aminoglycoside isomers
    Nakano, Yuta
    Sakamaki, Hiroshi
    Tasaki-Handa, Yuiko
    Saito, Shingo
    [J]. ANALYTICAL SCIENCES, 2024, 40 (03) : 375 - 384
  • [43] Current and future trends in reversed-phase liquid chromatography-mass spectrometry of therapeutic proteins
    D'Atri, Valentina
    Murisier, Amarande
    Fekete, Szabolcs
    Veuthey, Jean-Luc
    Guillarme, Davy
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2020, 130 (130)
  • [44] High-temperature reversed-phase liquid chromatography coupled to isotope ratio mass spectrometry
    Zhang, Lijun
    Kujawinski, Dorothea M.
    Jochmann, Maik A.
    Schmidt, Torsten C.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (20) : 2971 - 2980
  • [45] Method developments for iodine speciation by reversed-phase liquid chromatography-ICP-mass spectrometry
    Bernhard Michalke
    Peter Schramel
    Heidi Witte
    [J]. Biological Trace Element Research, 2000, 78 : 67 - 79
  • [46] Nanoscale reversed-phase liquid chromatography-mass spectrometry of permethylated N-glycans
    Ritamo, Ilja
    Rabina, Jarkko
    Natunen, Suvi
    Valmu, Leena
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (08) : 2469 - 2480
  • [47] Speciation Analysis of Thallium by Reversed-phase Liquid Chromatography - Inductively Coupled Plasma Mass Spectrometry
    Chu, Yun-Ling
    Wang, Ruoh-Yun
    Jiang, Shiuh-Jen
    [J]. JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2012, 59 (02) : 219 - 225
  • [48] LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY INVESTIGATION OF THE REVERSED-PHASE SEPARATION OF FULLERENES AND THEIR DERIVATIVES
    ANACLETO, JF
    QUILLIAM, MA
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (17) : 2236 - 2242
  • [49] Iodine speciation in human serum by reversed-phase liquid chromatography-ICP-mass spectrometry
    Michalke, B
    Schramel, P
    Witte, H
    [J]. BIOLOGICAL TRACE ELEMENT RESEARCH, 2000, 78 (1-3) : 81 - 91
  • [50] Iodine speciation in human serum by reversed-phase liquid chromatography-ICP-mass spectrometry
    Bernhard Michalke
    Peter Schramel
    Heidi Witte
    [J]. Biological Trace Element Research, 2000, 78 : 81 - 91