Assessing the hydrophobicity of glycopeptides using reversed-phase liquid chromatography and tandem mass spectrometry

被引:1
|
作者
Wang, Junyao [1 ]
Yu, Aiying [1 ]
Cho, Byeong Gwan [1 ]
Mechref, Yehia [1 ]
机构
[1] Texas Tech Univ, Dept Chem & Biochem, Lubbock, TX USA
关键词
Glycopeptides; Hydrophobicity; Reversed-phase LC; Tandem MS; PEPTIDE RETENTION TIMES; PROTEIN GLYCOSYLATION; ENRICHMENT METHODS; CANCER BIOMARKERS; GLYCAN STRUCTURES; LC-MS/MS; PREDICTION; IDENTIFICATION; SEQUENCE; MODEL;
D O I
10.1016/j.chroma.2023.464237
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Retention time is one of the most important parameters that has been widely used to demonstrate the separation results obtained from liquid chromatography (LC) platforms. However, retention time can shift when samples are tested with different instruments and laboratories, which hinders the identification process of analytes when comparing data collected from different LC systems. To address this problem, hydrophobicity index was introduced for retention time normalization of the glycopeptides separated by reversed-phase LC (RPLC). Tandem MS was used for the detection and identification of glycopeptides. In addition, the influence of different types of glycans on the hydrophobicity of peptide backbones was studied by comparing the retention time of glycopeptides with their non-glycosylated counterparts. The hydrophobicity of tryptic digested glycopeptides derived from model glycoproteins, including bovine fetuin, & alpha;1-acid glycoprotein, and haptoglobin from human plasma, were evaluated based on the hydrophobicity index of the standard peptides from a peptide retention time calibration mixture. The reduction of hydrophobicity of multiple peptide backbones was observed due to the hydrophilic glycan structures. By comparing the hydrophobicity index of glycopeptides collected from different time and instruments, the day-to-day and lab-to-lab comparisons suggested high reliability and reproducibility of this approach. The RSD% of hydrophobicity index from inter-lab experiments was 1.2%, while the RSD% of retention time was 5.1%. Then, the applications of this method were demonstrated on complex glycopeptide samples extracted from human blood serum. The hydrophobicity index can be applied to address the retention time shift when using different instruments, thereby boosting confidence of the characterization of glycopeptides.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Determination of Diquat Residues in Potato Using Reversed-Phase Liquid Chromatography with Tandem Mass Spectrometry
    Attallah, Emad R.
    Soliman, Mostafa
    Abo-Aly, Mohamed M.
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2017, 100 (03) : 789 - 795
  • [2] Analysis of lecithin in cosmetics by reversed-phase liquid chromatography electrospray tandem mass spectrometry
    Lee, MH
    Yoo, JS
    Lee, GH
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1998, 12 (22) : 1709 - 1714
  • [3] Determination of urine catecholamines and metanephrines by reversed-phase liquid chromatography-tandem mass spectrometry
    CHEUK Man-Yung
    LO Yun-Chuen
    POON Wing-Tat
    [J]. 色谱, 2017, (10) : 1042 - 1047
  • [4] Evaluation of comprehensive multidimensional separations using reversed-phase, reversed-phase liquid chromatography/mass spectrometry for shotgun proteomics
    Nakamura, Tatsuji
    Kuromitsu, Junro
    Oda, Yoshiya
    [J]. JOURNAL OF PROTEOME RESEARCH, 2008, 7 (03) : 1007 - 1011
  • [5] Quantification of corticosteroids in bovine urine using selective solid phase extraction and reversed-phase liquid chromatography/tandem mass spectrometry
    Tolgyesi, Adam
    Sharma, Virender K.
    Kovacsics, Lorena
    Fekete, Jeno
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (19): : 1471 - 1479
  • [6] Determination of ten hexabromocyclododecane diastereoisomers using two coupled reversed-phase columns and liquid chromatography/tandem mass spectrometry
    Han, Qian
    Song, Han
    Gao, Shutao
    Zeng, Xiangying
    Yu, Zhiqiang
    Yu, Yunjiang
    Sheng, Guoying
    Fu, Jiamo
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2014, 28 (13) : 1473 - 1478
  • [7] Microchip-based reversed-phase liquid chromatography tandem mass spectrometry platform for protein analysis
    Liang Yu
    Wu Ci
    Dai Zhongpeng
    Liang Zuocheng
    Liang Zhen
    Zhang Lihua
    Zhang Yukui
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2011, 29 (06) : 469 - 474
  • [8] Identification and relative quantification of peptides by capillary reversed-phase liquid chromatography-tandem mass spectrometry
    Li Xin
    Jiang Xinning
    Zou Hanfa
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2008, 26 (02) : 189 - 194
  • [9] Assessment of antibody fragmentation by reversed-phase liquid chromatography and mass spectrometry
    Liu, Hongcheng
    Gaza-Bulseco, Georgeen
    Lundell, Edwin
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 876 (01): : 13 - 23
  • [10] Estimating the hydrophobicity extent of molecular fragments using reversed-phase liquid chromatography
    Carotti, Andrea
    Varfaj, Ina
    Pruscini, Ilaria
    Abualzulof, Ghaid W. A.
    Mercolini, Laura
    Bianconi, Elisa
    Macchiarulo, Antonio
    Camaioni, Emidio
    Sardella, Roccaldo
    [J]. JOURNAL OF SEPARATION SCIENCE, 2023, 46 (18)