Side-by-Side Comparison of Methods for Environmental Monitoring for Hazardous Drug Contamination

被引:0
|
作者
Hon, Chun-Yip [1 ]
机构
[1] Toronto Metropolitan Univ, Sch Occupat & Publ Hlth, Toronto, ON, Canada
来源
CANADIAN JOURNAL OF HOSPITAL PHARMACY | 2023年 / 76卷 / 02期
关键词
hazardous drugs; HD Check system; risk assessment; surface contamination; wipe sampling;
D O I
10.4212/cjhp.3275
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: Exposure to hazardous drugs is known to have deleterious effects on health care workers. To assess risk, environmental monitoring is conducted to ascertain drug contamination on surfaces, as dermal contact is the main route of exposure. Conventional monitoring employs wipe sampling whereby the wipe must be sent to a laboratory for analysis. This means that quantitative results are not available for some time, during which the risk remains unknown. A new device, the HD Check system, developed by BD, which uses lateral-flow immunoassay technology, allows for near real-time qualitative assessment of contamination (positive or negative); however, its sensitivity relative to the traditional method is unknown. Objective: To evaluate the ability of this novel device to detect drug contamination relative to the conventional method. Methods: Five sets of different known drug concentrations were compared between the conventional wipe sampling method and the HD Check systems for methotrexate (MTX) and cyclophosphamide (CP). Stainless steel surfaces were tested, and the drug concentrations ranged from 0 ng/cm(2) to twice the limit of detection (LOD) of each HD Check system. Results: For MTX, positive results were obtained in every test trial at all drug concentrations examined with the HD Check system (LOD = 0.93 ng/cm(2)). For CP, test results with the HD Check system (LOD = 4.65 ng/cm(2)) were all positive at the LOD and twice the LOD; however, at 50% and 75% of the LOD, the result was positive in only 90% (9/10) of the trials. The conventional method was able to quantify the test drug concentrations with a high level of accuracy and reproducibility. Conclusions: These results suggest the potential utility of the novel device as a screening tool for higher levels of drug contamination with MTX and CP, but additional research is needed to determine its suitability for lower concentrations, especially of CP.
引用
收藏
页码:87 / 93
页数:7
相关论文
共 50 条
  • [21] A side-by-side comparison of Rotorod and Burkard pollen and spore collections
    Crisp, Howard C.
    Gomez, Robert A.
    White, Kevin M.
    Quinn, James M.
    [J]. ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2013, 111 (02) : 118 - 125
  • [22] Melanoma diagnosed on digital dermoscopy monitoring: A side-by-side image comparison is needed to improve early detection
    Babino, Graziella
    Lallas, Aimilios
    Agozzino, Marina
    Alfano, Roberto
    Apalla, Zoe
    Brancaccio, Gabriella
    Giorgio, Caterina M.
    Fulgione, Elisabetta
    Kittler, Harald
    Kyrgidis, Athanassios
    Papageorgiou, Chryssuola
    Argenziano, Giuseppe
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2021, 85 (03) : 619 - 625
  • [23] A SIDE-BY-SIDE COMPARISON OF DUST COLLECTION METHODS FOR SAMPLING LEAD-CONTAMINATED HOUSE-DUST
    LANPHEAR, BP
    EMOND, M
    JACOBS, DE
    WEITZMAN, M
    TANNER, M
    WINTER, NL
    YAKIR, B
    EBERLY, S
    [J]. ENVIRONMENTAL RESEARCH, 1995, 68 (02) : 114 - 123
  • [24] Side-by-side comparisons of traditional and modern methods of measuring earth temperatures
    Pettifer, R. E. W.
    [J]. WEATHER, 2008, 63 (10) : 317 - 317
  • [25] Biomechanical Comparison of Lasso, Pulvertaft Weave, and Side-by-Side Tendon Repairs
    Bidic, Sean M.
    Varshney, Anubodh
    Ruff, Matthew D.
    Orenstein, Harry H.
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2009, 124 (02) : 567 - 571
  • [26] Side-by-side comparison of Raman spectra of anchored and suspended carbon nanomaterials
    Sidorov, Anton N.
    Pabba, Santosh
    Hewaparakrama, Kapila P.
    Cohn, Robert W.
    Sumanasekera, G. U.
    [J]. NANOTECHNOLOGY, 2008, 19 (19)
  • [27] A Side-By-Side Comparison of the Next Generation Optical Neuromodulators of Retinal Activity
    Greenberg, K. P.
    Pham, A.
    Werblin, F. S.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [28] Need for Randomization in Side-by-side FDG-PET Comparison Studies
    Tegelaar, A.
    Koopman, D.
    Jager, P. L.
    Slump, C. H.
    Rombouts, E. C.
    Winkels, M.
    van Dalen, J. A.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S139 - S140
  • [29] A side-by-side comparison of carbon dioxide resurfacing lasers for the treatment of rhytides
    Gross, EA
    Rogers, GS
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 1998, 39 (04) : 547 - 553
  • [30] Side-by-Side Comparison of Post-Entry Quarantine and High Throughput Sequencing Methods for Virus and Viroid Diagnosis
    Gauthier, Marie-Emilie A.
    Lelwala, Ruvini V.
    Elliott, Candace E.
    Windell, Craig
    Fiorito, Sonia
    Dinsdale, Adrian
    Whattam, Mark
    Pattemore, Julie
    Barrero, Roberto A.
    [J]. BIOLOGY-BASEL, 2022, 11 (02):