With the increasing concern about global energy crisis and environmental pollution, the integrated renewable energy system has gradually become one of the most important ways to achieve energy transition. In the context of the rapid development of hydrogen energy industry, the proportion of hydrogen energy in the energy system has gradually increased. The conversion between various energy sources has also become more complicated, which poses challenges to the planning and construction of park-level integrated energy systems (PIES). To solve this problem, we propose a bi-level planning model for an integrated energy system with hydrogen energy, considering multi-stage investment and carbon trading mechanism. First, the mathematical models of each energy source and energy storage in the park are established respectively, and the independent operation of the equipment is analyzed. Second, considering the operation state of multi-energy coordination, a bi-level planning optimization model is established. The upper level is the capacity configuration model considering the variable installation time of energy facilities, while the lower level is the operation optimization model considering several typical daily operations. Third, considering the coupling relationship between upper and lower models, the bi-level model is transformed into a solvable single-level mixed integer linear programming (MILP) model by using Karush-Kuhn-Tucker (KKT) condition and big-M method. Finally, the proposed model and solution methods are verified by comprehensive case studies. Simulation results show that the proposed model can reduce the operational cost and carbon emission of PIES in the planning horizon, and provide insights for the multi-stage investment of PIES. (c) 2023 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:554 / 566
页数:13
相关论文
共 50 条
  • [1] Low-carbon planning of park-level integrated energy system considering generalized energy storage
    Zhang, Xiao
    Chen, Sheng
    Wei, Zhinong
    Liang, Zeyu
    [J]. Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2024, 44 (03): : 40 - 48
  • [2] Optimal configuration of park-level integrated energy system considering integrated demand response and construction time sequence
    Liu, Chang
    Li, Yan
    Wang, Qingshan
    Wang, Xin
    Chen, Changming
    Lin, Zhenzhi
    Yang, Li
    [J]. ENERGY REPORTS, 2022, 8 : 1174 - 1180
  • [3] Multi-stage Planning of Park-level Integrated Energy System Considering Construction Time Sequence
    Cao, Yan
    Mu, Yunfei
    Jia, Hongjie
    Yu, Xiaodan
    Song, Yi
    Wu, Kuihua
    [J]. Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2020, 40 (21): : 6815 - 6827
  • [4] Optimal Configuration Method of Park-level Integrated Energy System Considering Optimal Construction Time Sequence and Cloud Energy Storage
    Chen, Changming
    Zhang, Qun
    Huang, Yixin
    Wang, Xin
    Wang, Decheng
    Yang, Li
    Lin, Zhenzhi
    [J]. Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2022, 46 (02): : 24 - 32
  • [5] Low-carbon Operation of Park-level Integrated Energy System Considering Shared Energy Storage Features of Electric Vehicles
    Wang, Yi
    Jin, Zikang
    Wang, Yaoqiang
    Liu, Mingyang
    Liang, Jun
    [J]. Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2024, 48 (05): : 21 - 29
  • [6] Distributionally Robust Low-carbon Dispatch of Park-level Integrated Energy System Considering Uncertainty of Customer Response
    Jin, Xudong
    Sun, Lei
    Ding, Ming
    Wen, Fushuan
    Sun, Wei
    [J]. Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2023, 47 (16): : 10 - 21
  • [7] Low-Carbon Operation Strategy of Park-Level Integrated Energy System with Firefly Algorithm
    Chen, Hongyin
    Wang, Songcen
    Yu, Yaoxian
    Guo, Yi
    Jin, Lu
    Jia, Xiaoqiang
    Liu, Kaicheng
    Zhang, Xinhe
    [J]. APPLIED SCIENCES-BASEL, 2024, 14 (13):
  • [8] Dispatching Strategy for Low-Carbon Flexible Operation of Park-Level Integrated Energy System
    Meng, Qinglin
    Zu, Guoqiang
    Ge, Leijiao
    Li, Shengwei
    Xu, Liang
    Wang, Rui
    He, Kecheng
    Jin, Shangting
    [J]. APPLIED SCIENCES-BASEL, 2022, 12 (23):
  • [9] Low-carbon Economic Dispatch of Park-level Integrated Energy System Considering Carbon Trading and Flexible Response of Supply Side
    Zhou, Wei
    Yin, Chenxu
    Zhang, Zhaoqing
    Meng, Yunfan
    Chen, Li
    Sun, Yonghui
    [J]. 2023 IEEE/IAS INDUSTRIAL AND COMMERCIAL POWER SYSTEM ASIA, I&CPS ASIA, 2023, : 712 - 717
  • [10] Low-carbon Economic Scheduling Considering Multiple Park-level Integrated Energy Systems Cooperation in Uncertain Environment
    Cheng, Yan
    Yu, Peng
    Xing, Jiawei
    Li, Yong
    Yao, Wenliang
    Wang, Kang
    Sun, Shumin
    Wang, Shibo
    [J]. 2023 IEEE/IAS INDUSTRIAL AND COMMERCIAL POWER SYSTEM ASIA, I&CPS ASIA, 2023, : 824 - 830