Prevention, diagnosis and treatment of implantable electronic cardiac device infections. Position paper of the Italian Association of Arrhythmology and Cardiostimulation (AIAC)

被引:0
|
作者
Pisano, Ennio Carmine [1 ]
Mitacchione, Gianfranco [2 ]
Pappalardo, Augusto [3 ]
Di Grazia, Angelo [4 ]
Solimene, Francesco [5 ]
Boriani, Giuseppe [6 ]
Migliore, Federico [7 ,9 ]
Curnis, Antonio [8 ]
机构
[1] Osped V Fazzi, UOSVD Elettrofisiol Cardiol, Lecce, Italy
[2] UOC Cardiol & UTIC, Polo Univ, Osped Luigi Sacco, Milano, TX USA
[3] UOC Cardiol, Osped San Camillo Forlanini, Roma, TX USA
[4] UOC Cardiol, Osped Policlin G Rodol, Catania, Italy
[5] Clin Montevergine, Lab Elettrofisiol, Mercogliano, AV, Italy
[6] Univ Modena & Reggio Emilia, Dipartimento Sci Biomed Metab & Neurosci, Cardiol, Modena, Italy
[7] Univ Padua, Dipartimento Sci Cardiotoraco Vasc & San Pubbl, Padua, Italy
[8] Univ Brescia, UOC Cardiol, Spedali Civili, Brescia, Italy
[9] Univ Padua, Dipartimento Sci Cardiotoraco Vasc & San Pubbl, Via Giustiniani 2, I-35121 Padua, Italy
关键词
Cardiac implantable electronic device; Cardiac implantable electronic device infection; Transvenous lead extraction; TRANSVENOUS LEAD EXTRACTION; EXPERT CONSENSUS STATEMENT; REAL-WORLD DATA; CARDIOVERTER-DEFIBRILLATORS; RISK-FACTORS; PACEMAKER IMPLANTATION; CHLORHEXIDINE-ALCOHOL; PERMANENT PACEMAKER; POVIDONE-IODINE; OUTCOMES;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The number of cardiac implantable electronic device (CIED) implantations has increased over recent years as a result of population growth, increasing life expectancy, adoption of guidelines, and better access to healthcare. Device-related infection is, however, one of the most serious complications of CIED therapy associated with significant morbidity, mortality, and financial healthcare burden. Although many preventive strategies such as administration of intravenous antibiotic therapy before implantation are well recognized, uncertainties still exist about other regimens. Uncertainties have remained about the role of various preventive, diagnostic, and treatment measures such as skin antiseptics, pocket antibiotic solutions, anti-bacterial envelopes, prolonged antibiotics post-implantation, and others. The key aspect to successful treatment of definite CIED infections is complete removal of all parts of the system and transvenous hardware, including the device and all leads. Thus, transvenous lead extraction has been increasing. Expert consensus statements on how to prevent, diagnose, and treat CIED infections and on lead extraction have been published by the European Heart Rhythm Association in 2020 and 2018, respectively. The aim of this AIAC position paper is to describe the current knowledge on the risks for device-related infections and to assist healthcare professionals in their clinical decision making regarding its prevention, diagnosis, and management by providing the latest update of the most effective strategies.
引用
收藏
页码:551 / 570
页数:20
相关论文
共 50 条
  • [1] Position paper of the Italian Association of Arrhythmology and Cardiostimulation (AIAC): Recommendations on the fitness to drive of patients with implantable cardiac devices
    Palmisano, Pietro
    Guerra, Federico
    Bisignani, Giovanni
    Forleo, Giovanni Battista
    Landolina, Maurizio
    Soldati, Ezio
    Stabile, Giuseppe
    Zanotto, Gabriele
    Berisso, Massimo Zoni
    De Ponti, Roberto
    Boriani, Giuseppe
    Ricci, Renato Pietro
    [J]. GIORNALE ITALIANO DI CARDIOLOGIA, 2020, 21 (10) : 819 - 825
  • [2] Clinical and organizational management of cardiac implantable electronic device replacements: an Italian Survey promoted by AIAC (Italian Association of Arrhythmology and Cardiac Pacing)
    Palmisano, Pietro
    Ziacchi, Matteo
    Belotti, Giuseppina
    Rapacciuolo, Antonio
    Santini, Luca
    Stabile, Giuseppe
    Berisso, Massimo Zoni
    De Ponti, Roberto
    Landolina, Maurizio
    Ricci, Renato Pietro
    Boriani, Giuseppe
    Andriani, A.
    Infusino, T.
    D'Angelo, G.
    Del Giorno, G.
    Stabile, G.
    D'Onofrio, A.
    Bianchi, V
    Sangiuolo, R.
    Rapacciuolo, A.
    Viciglione, C.
    Sassone, B.
    Virzi, S.
    Bagni, E.
    Scapinelli, M.
    Bandini, A.
    Biancoli, S.
    Casali, E.
    Buia, E.
    Pastori, P.
    Sabbatani, P.
    Corzani, A.
    Tomasi, C.
    Dal Monte, A.
    Giannotti, F.
    Arniani, S.
    Zardini, M.
    Placci, A.
    Palpacelli, C.
    Biffi, M.
    Martignani, C.
    Diaemberger, I
    Piovaccari, G.
    Saporito, D.
    Fabbri, F.
    De Maria, E.
    Bottoni, N.
    Quartieri, F.
    Bertini, M.
    Malagu, M.
    [J]. JOURNAL OF CARDIOVASCULAR MEDICINE, 2019, 20 (08) : 531 - 541
  • [3] Prevention, Diagnosis, and Treatment of Cardiac Implantable Electronic Device Infections
    Leung, Steven
    Danik, Stephan
    [J]. CURRENT CARDIOLOGY REPORTS, 2016, 18 (06)
  • [4] Prevention, Diagnosis, and Treatment of Cardiac Implantable Electronic Device Infections
    Steven Leung
    Stephan Danik
    [J]. Current Cardiology Reports, 2016, 18
  • [5] Impact of COVID-19 Pandemic on Remote Monitoring of Cardiac Implantable Electronic Devices in Italy: Results of a Survey Promoted by AIAC (Italian Association of Arrhythmology and Cardiac Pacing)
    Maines, Massimiliano
    Palmisano, Pietro
    Del Greco, Maurizio
    Melissano, Donato
    De Bonis, Silvana
    Baccillieri, Stella
    Zanotto, Gabriele
    D'Onofrio, Antonio
    Ricci, Renato Pietro
    De Ponti, Roberto
    Boriani, Giuseppe
    [J]. JOURNAL OF CLINICAL MEDICINE, 2021, 10 (18)
  • [6] Prevention of Cardiac Implantable Electronic Device Infections: A Review
    Slawinski, Grzegorz
    Kempa, Maciej
    Przybylski, Andrzej
    [J]. REVIEWS IN CARDIOVASCULAR MEDICINE, 2023, 24 (06)
  • [7] Lead choice in cardiac implantable electronic devices: an Italian survey promoted by AIAC (Italian Association of Arrhythmias and Cardiac Pacing)
    Ziacchi, Matteo
    Palmisano, Pietro
    Biffi, Mauro
    Guerra, Federico
    Stabile, Giuseppe
    Forleo, Giovanni Battista
    Zanotto, Gabriele
    D'Onofrio, Antonio
    Landolina, Maurizio
    De Ponti, Roberto
    Berisso, Massimo Zoni
    Ricci, Renato Pietro
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2019, 16 (09) : 821 - 828
  • [8] Prevention of cardiac implantable electronic device infections: An unresolved issue
    Altunbas, Gokhan
    Vuruskan, Ertan
    Sucu, Murat
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2019, 42 (05): : 564 - 564
  • [9] Change in the use of remote monitoring of cardiac implantable electronic devices in Italian clinical practice over a 5-year period: results of two surveys promoted by the AIAC (Italian Association of Arrhythmology and Cardiac Pacing)
    Palmisano, Pietro
    Melissano, Donato
    Zanotto, Gabriele
    Perego, Giovanni Battista
    Toselli, Tiziano
    Landolina, Maurizio
    Ricci, Renato Pietro
    [J]. JOURNAL OF CARDIOVASCULAR MEDICINE, 2020, 21 (04) : 305 - 314
  • [10] Etiology and microbiological diagnosis of cardiac implantable electronic device infections