RESEARCH AND EDUCATION Effect of different fabrication methods of occlusal devices on periradicular stress distribution: A photoelastic analysis

被引:2
|
作者
Arcas, Luciana Paula Benicio [1 ,3 ]
Baroudi, Kusai [2 ]
Silva-Concilio, Lais Regiane [2 ]
Claro, Cristiane Aparecida de Assis [2 ]
Amaral, Marina [2 ]
机构
[1] Univ Taubate UNITAU, Dept Dent, Pos Grad Program Dent, Taubate, Brazil
[2] Univ Taubate UNITAU, Dept Restorat Dent, Dept Dent, Taubate, Brazil
[3] Univ Taubate UNITAU, Dept Dent, Rua Operarios 09, BR-12020270 Taubate, SP, Brazil
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2023年 / 129卷 / 04期
关键词
POLYMERIC MATERIALS; ORAL APPLIANCES; LOAD-TRANSFER; DENTURES; BRUXISM; ADULTS; SPLINT;
D O I
10.1016/j.prosdent.2021.06.037
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Investigations on the effectiveness of new methods for optimizing the fabrication of oral devices are lacking. Purpose. The purpose of this in vitro study was to evaluate stress distribution with photoelastic analysis in the periradicular area of teeth supporting occlusal devices fabricated by 5 different processes. Material and methods. The occlusal devices were fabricated by vacuum thermoforming, heat-polymerized acrylic resin, chemical polymerized acrylic resin, 3-dimensional printing, and milling (computer-aided manufacturing). The devices were evaluated regarding initial fit, number of adjustments for passive fit, and stress distribution under 100-N and 400-N loads in the periradicular locations of posterior teeth.Results. The 3-dimensional printing device did not require any adjustment for initial adaptation to the photoelastic model and presented a little friction with the model. The heat-polymerized acrylic resin device did not seat initially, requiring more sites of adjustment until passive adaptation. At 100-N and 400-N loads, the use of the computer-aided manufacturing occlusal device resulted in the lowest stresses in periradicular areas (0.744 and 1.583, respectively), and the 3-dimensional printing occlusal device produced the highest stresses with a 400-N load application (2.427). The lowest mean of fringe pattern was observed for the computer-aided manufacturing device, and the highest mean of fringe pattern was observed for the vacuum thermoforming device.Conclusions. The computer-aided design and computer-aided manufacturing milled occlusal device presented the best initial adaptation and transferred lower stresses to the periradicular areas than the other evaluated devices.
引用
收藏
页码:651 / 656
页数:6
相关论文
共 49 条
  • [1] Photoelastic Analysis of Stress Distribution With Different Implant Systems
    Pellizzer, Eduardo Piza
    Carli, Rafael Imai
    Falcon-Antenucci, Rosse Mary
    Verri, Fellippo Ramos
    Goiato, Marcelo Coelho
    Villa, Luiz Marcelo Ribeiro
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (02) : 117 - 122
  • [2] Photoelastic stress analysis of different post and core restoration methods
    Yamamoto, Masahiro
    Miura, Hiroyuki
    Okada, Daizo
    Komada, Wataru
    Masuoka, David
    [J]. DENTAL MATERIALS JOURNAL, 2009, 28 (02) : 204 - 211
  • [3] Stress distribution around implants with different interproximal contacts: A photoelastic analysis
    Araujo, C. A.
    Naves, M. M.
    de Menezes, H. H. M.
    de Magalhaes, D.
    Neves, F. D.
    Junior, P. C. S.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 11: BIOMEDICAL ENGINEERING FOR AUDIOLOGY, OPHTHALMOLOGY, EMERGENCY AND DENTAL MEDICINE, 2009, 25 (11): : 320 - +
  • [4] Photoelastic Analysis of Stress Distribution in Different Retention Systems for Facial Prosthesis
    Goiato, Marcelo Coelho
    Ribeiro, Paula do Prado
    Pellizzer, Eduardo Piza
    Garcia Junior, Idelmo Rangel
    Pesqueira, Aldieris Alves
    Haddad, Marcela Filie
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2009, 20 (03) : 757 - 761
  • [5] Effect of different occlusal materials on peri-implant stress distribution with different osseointegration condition: A finite element analysis
    Thirumaran, Dhanasekaran
    Leoney, Andonissamy
    Fayeez, Abdullah
    Yazhini Shanmya, Paramasivam
    [J]. JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2024, 24 (03): : 292 - 299
  • [6] Photoelastic analysis of dynamic stress distribution around short implants restored with different materials
    Burgoa-La-Forcada, S. M.
    Edwards Rezende, C. E.
    Castiglia Gonzaga, C.
    Cesar Zielak, J.
    Yoshio Furuse, A.
    [J]. JOURNAL OF OSSEOINTEGRATION, 2018, 10 (02) : 44 - 49
  • [7] Photoelastic Analysis of the Distribution of Stress in Different Systems of Overdentures on Osseous-Integrated Implants
    Masarolo Machado, Ana Carolina
    Cardoso, Leandro
    Brandt, William Cunha
    Pessanha Henriques, Guilherme Elias
    de Arruda Nobilo, Mauro Antonio
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2011, 22 (06) : 2332 - 2336
  • [8] Evaluation of Biomechanical and Stress Distribution of Different Dental Implant Designs: Primary Stability and Photoelastic Analysis
    Tardelli, J. D. C.
    Macedo, A. P.
    Valente, da Costa
    [J]. IRBM, 2022, 43 (02) : 100 - 106
  • [9] Stress Distribution Around Osseointegrated Implants With Different Internal-Cone Connections: Photoelastic and Finite Element Analysis
    Anami, Lilian Costa
    da Costa Lima, Julia Magalhaes
    Takahashi, Fernando Eidi
    Neisser, Maximiliano Piero
    Noritomi, Pedro Yoshito
    Bottino, Marco Antonio
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (02) : 155 - 162
  • [10] Effect of mucosa thicknesses on stress distribution of implant-supported overdentures under unilateral loading: Photoelastic analysis
    Ozyilmaz, Ozgun Yusuf
    Aykent, Filiz
    Ozel, Gulsum Sayin
    [J]. JOURNAL OF APPLIED BIOMATERIALS & FUNCTIONAL MATERIALS, 2019, 17 (04)