The 40-Hz auditory steady-state response enhanced by beta-band subharmonics

被引:1
|
作者
Sugiyama, Shunsuke [1 ]
Taniguchi, Tomoya [2 ]
Kinukawa, Tomoaki [2 ]
Takeuchi, Nobuyuki [3 ]
Ohi, Kazutaka [1 ]
Shioiri, Toshiki [1 ]
Nishihara, Makoto [4 ]
Inui, Koji [5 ,6 ]
机构
[1] Gifu Univ, Dept Psychiat, Grad Sch Med, Gifu, Japan
[2] Nagoya Univ, Dept Anesthesiol, Grad Sch Med, Nagoya, Japan
[3] Aichi Med Univ, Neuropsychiat Dept, Nagakute, Japan
[4] Aichi Med Univ, Multidisciplinary Pain Ctr, Nagakute, Japan
[5] Aichi Dev Disabil Ctr, Inst Dev Res, Dept Functioning & Disabil, Kasugai, Japan
[6] Natl Inst Physiol Sci, Sect Brain Funct Informat, Okazaki, Japan
关键词
auditory steady-state response; oscillation; harmonic; magnetoencephalography; schizophrenia; ERD/ERS RESPONSES; GAMMA RHYTHM; FREQUENCY; OSCILLATIONS; AMPLITUDE; RANGE; SCHIZOPHRENIA; STIMULATION; POTENTIALS; GENERATION;
D O I
10.3389/fnins.2023.1127040
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The 40-Hz auditory steady-state response (ASSR) has received special attention as an index of gamma oscillations owing to its association with various neuropsychiatric disorders including schizophrenia. When a periodic stimulus is presented, oscillatory responses are often elicited not only at the stimulus frequency, but also at its harmonic frequencies. However, little is known about the effect of 40-Hz subharmonic stimuli on the activity of the 40-Hz ASSR. In the present magnetoencephalography study, we focused on the nature of oscillation harmonics and examined oscillations in a wide frequency range using a time-frequency analysis during the 6.67-, 8-, 10-, 13.3-, 20-, and 40-Hz auditory stimuli in 23 healthy subjects. The results suggested that the 40-Hz ASSR represents activation of a specific circuit tuned to this frequency. Particularly, oscillations elicited by 13.3- and 20-Hz stimuli exhibited significant enhancement at 40 Hz without changing those at the stimulus frequency. In addition, it was found that there was a non-linear response to stimulation in the beta band. We also demonstrated that the inhibition of beta to low-gamma oscillations by the 40-Hz circuit contributed to the violation of the rule that harmonic oscillations gradually decrease at higher frequencies. These findings can advance our understanding of oscillatory abnormalities in patients with schizophrenia in the future.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Atypical brain responses to 40-Hz click trains in girls with Rett syndrome: Auditory steady-state response and sustained wave
    Neklyudova, Anastasia
    Kuramagomedova, Rabiat
    Voinova, Victoria
    Sysoeva, Olga
    [J]. PSYCHIATRY AND CLINICAL NEUROSCIENCES, 2024, 78 (05) : 282 - 290
  • [42] Phase-locking index and power of 40-Hz auditory steady-state response are not related to major personality trait dimensions
    Korostenskaja, Milena
    Ruksenas, Osvaldas
    Pipinis, Evaldas
    Griskova-Bulanova, Inga
    [J]. EXPERIMENTAL BRAIN RESEARCH, 2016, 234 (03) : 711 - 719
  • [43] Source analysis of the 40 Hz auditory steady-state response deficit in schizophrenia
    Spencer, Kevin M.
    McCarley, Robert W.
    [J]. BIOLOGICAL PSYCHIATRY, 2008, 63 (07) : 220S - 220S
  • [44] Detection of the 40 Hz auditory steady-state response with optically pumped magnetometers
    An, Kyung-min
    Shim, Jeong Hyun
    Kwon, Hyukchan
    Lee, Yong-Ho
    Yu, Kwon-Kyu
    Kwon, Moonyoung
    Chun, WooYoung
    Hirosawa, Tetsu
    Hasegawa, Chiaki
    Iwasaki, Sumie
    Kikuchi, Mitsuru
    Kim, Kiwoong
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01)
  • [45] Phase-locking index and power of 40-Hz auditory steady-state response are not related to major personality trait dimensions
    Milena Korostenskaja
    Osvaldas Ruksenas
    Evaldas Pipinis
    Inga Griskova-Bulanova
    [J]. Experimental Brain Research, 2016, 234 : 711 - 719
  • [46] Detection of the 40 Hz auditory steady-state response with optically pumped magnetometers
    Kyung-min An
    Jeong Hyun Shim
    Hyukchan Kwon
    Yong-Ho Lee
    Kwon-Kyu Yu
    Moonyoung Kwon
    Woo Young Chun
    Tetsu Hirosawa
    Chiaki Hasegawa
    Sumie Iwasaki
    Mitsuru Kikuchi
    Kiwoong Kim
    [J]. Scientific Reports, 12
  • [47] 40 Hz auditory steady-state response in females: When is it better to entrain?
    Griskova-Bulanova, Inga
    Griksiene, Ramune
    Korostenskaja, Milena
    Ruksenas, Osvaldas
    [J]. ACTA NEUROBIOLOGIAE EXPERIMENTALIS, 2014, 74 (01) : 91 - 97
  • [48] Gamma-band harmonic responses for beta-band auditory steady-state response are intact in patients with early stage schizophrenia
    Tada, Mariko
    Kirihara, Kenji
    Nagai, Tatsuya
    Koike, Shinsuke
    Araki, Tsuyoshi
    Kasai, Kiyoto
    [J]. NEUROPSYCHOPHARMACOLOGY REPORTS, 2024, 44 (01) : 240 - 245
  • [49] AUDITORY AND VISUAL EVENT-RELATED PERTURBATIONS IN THE 40 HZ AUDITORY STEADY-STATE RESPONSE
    ROHRBAUGH, JW
    VARNER, JL
    PAIGE, SR
    ECKARDT, MJ
    ELLINGSON, RJ
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1990, 76 (02): : 148 - 164
  • [50] Ipsilateral and contralateral recordings of the 40-Hz auditory steady state response (ASSR): Which one is better?
    Zakaria, M. N.
    Jalaei, B.
    Sidek, D.
    [J]. B-ENT, 2016, 12 (01): : 53 - 57