A polydopamine nanospheres modified fiber optic SPR biosensor for specific detection of C-reactive protein

被引:12
|
作者
Cao, Guangxiao [1 ,2 ]
Chang, Pengxiang [1 ,2 ,3 ]
Zhang, Ailing [1 ,2 ]
Liu, Fei [1 ,2 ]
Pan, Honggang [1 ,2 ]
Wang, Junfeng [1 ,2 ]
Lin, Sihang [1 ,2 ]
Yang, Tengfei [1 ,2 ]
机构
[1] Tianjin Univ Technol, Tianjin 300384, Peoples R China
[2] Tianjin Key Lab Thin Film Elect & Commun Devices, Tianjin 300384, Peoples R China
[3] Natl Key Lab Electromagnet Space Secur, Tianjin 300308, Peoples R China
关键词
C-reactive protein; Polydopamine nanospheres; Surface plasmon resonance; Optical biosensor; Immune reaction; PLASMON RESONANCE BIOSENSOR; GOLD;
D O I
10.1016/j.yofte.2023.103468
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
C-reactive protein (CRP) is a vital inflammatory marker in humans and a key single marker of cardiovascular diseases. In this paper, the concentration of CRP was specifically detected by a polydopamine nanospheres (PDANPs) developed surface plasmon resonance (SPR) sensor with high accuracy. PDA-NPs is a self-polymerizing material that can be obtained from dopamine through the mussel adhesion effect. The PDA-NPs (diameter & AP; 100 nm) modified SPR sensor exhibits enhanced refractive index (RI) sensitivity and bio-sensitivity attributed to the large specific surface area and high surface reactivity of the PDA-NPs. The developed sensor demonstrates a RI sensitivity of 2427.68 nm/RIU, presenting a 55.7% increase compared to the raw sensor (RI sensitivity was 1559.08 nm/RIU). Moreover, the developed biosensor is used to detect CRP specifically. The bio-sensitivity reaches 0.09 nm/(& mu;g/mL), while the limit of detection (LOD) reaches 0.22 & mu;g/mL. These findings indicate that the developed biosensor can specifically detect CRP with a low LOD. Therefore, this PDA-NPs modified biosensor has great potential in clinical detection and other bio-detection filed.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Fiber SPR biosensor sensitized by MOFs for MUC1 protein detection
    Wang, Rui
    Liu, Chunlan
    Wei, Yong
    Ran, Ze
    Jiang, Tianci
    Liu, Chunbiao
    Shi, Chen
    Ren, Zhuo
    Wang, Xingkai
    Liu, Zhihai
    Zhang, Yu
    TALANTA, 2023, 258
  • [32] Label-free detection of C-reactive protein using a carbon nanofiber based biosensor
    Gupta, Rakesh K.
    Periyakaruppan, Adaikkappan
    Meyyappan, M.
    Koehne, Jessica E.
    BIOSENSORS & BIOELECTRONICS, 2014, 59 : 112 - 119
  • [33] Numerical simulation of a microfluidic biosensor for C-reactive protein detection into a microchannel with considering electrothermal effect
    Hajji, Hassnia
    Kolsi, Lioua
    Ghachem, Kaouther
    Maatki, Chemseddine
    Borjini, Mohamed Naceur
    ALEXANDRIA ENGINEERING JOURNAL, 2020, 59 (03) : 1649 - 1659
  • [34] Detection of the Inflammation Biomarker C-Reactive Protein in Serum Samples: Towards an Optimal Biosensor Formula
    Fakanya, Wellington M.
    Tothill, Ibtisam E.
    BIOSENSORS-BASEL, 2014, 4 (04): : 340 - 357
  • [35] Electrochemical biosensor with electrokinetics-assisted molecular trapping for enhancing C-reactive protein detection
    Sheen, Horn-Jiunn
    Panigrahi, Bivas
    Kuo, Tsung-Rong
    Hsu, Wei-Chen
    Chung, Pei-Shan
    Xie, Qiu-Zhe
    Lin, Ching-Yu
    Chang, Yu-Sheng
    Lin, Chih-Ting
    Fan, Yu-Jui
    BIOSENSORS & BIOELECTRONICS, 2022, 210
  • [36] A Conductive Nanowire-Mesh Biosensor for Ultrasensitive Detection of Serum C-Reactive Protein in Melanoma
    Lin, Zuan-Tao
    Li, Yaxi
    Gu, Jianhua
    Wang, Huie
    Zhu, Zhuan
    Hong, Xia
    Zhang, Zijing
    Lu, Qinqin
    Qiu, Jingyi
    Wang, Xifan
    Bao, Jiming
    Wu, Tianfu
    ADVANCED FUNCTIONAL MATERIALS, 2018, 28 (31)
  • [37] Competitive inhibition assay for the detection of progesterone in dairy milk using a fiber optic SPR biosensor
    Daems, D.
    Lu, J.
    Delport, F.
    Marien, N.
    Orbie, L.
    Aernouts, B.
    Adriaens, I.
    Huybrechts, T.
    Saeys, W.
    Spasic, D.
    Lammertyn, J.
    ANALYTICA CHIMICA ACTA, 2017, 950 : 1 - 6
  • [38] Development of a sensitive SPR biosensor for C-reactive protein (CRP) using plasma-treated parylene-N film
    Choi, Yong-Hwan
    Ko, Hyuk
    Lee, Ga-Yeon
    Chang, Seo-Yoon
    Chang, Young Wook
    Kang, Min-Jung
    Pyun, Jae-Chul
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 207 : 133 - 138
  • [39] Interference of antimodified C-reactive protein autoantibodies from lupus nephritis in the biofunctions of modified C-reactive protein
    Yang, Xiao-wei
    Tan, Ying
    Yu, Feng
    Zhao, Ming-hui
    HUMAN IMMUNOLOGY, 2012, 73 (02) : 156 - 163
  • [40] Metal-Organic Frameworks Modified Optical Fiber SPR Biosensor for DNA Detection
    Li, Lingling
    Yu, Shen
    Jing, Chonglu
    Chen, Lihua
    Zhou, Ai
    IEEE SENSORS JOURNAL, 2024, 24 (11) : 17387 - 17394