Correcting gradient chain induced fat quantification errors in radial multi-echo Dixon imaging using a gradient modulation transfer function

被引:0
|
作者
Zoellner, Christoph [1 ]
Kronthaler, Sophia [1 ]
Weiss, Kilian [2 ]
Boehm, Christof [1 ]
Stelter, Jonathan [1 ]
Rahmer, Juergen [3 ]
Boernert, Peter [3 ]
Peeters, Johannes M. [4 ]
Junker, Daniela [1 ]
Karampinos, Dimitrios C. [1 ]
机构
[1] Tech Univ Munich, Sch Med, Dept Diagnost & Intervent Radiol, Munich, Germany
[2] Philips GmbH Market DACH, Hamburg, Germany
[3] Philips Res Labs, Hamburg, Germany
[4] Philips Healthcare, Best, Netherlands
关键词
eddy currents; gradient delays; k-space trajectory distortions; radial; stack-of-stars; proton density fat fraction (PDFF); Dixon imaging; magnetic resonance imaging (MRI); PHASE ERRORS; WATER/FAT SEPARATION; SYSTEM CHARACTERIZATION; HEPATIC FAT; LIVER FAT; RECONSTRUCTION; MRI;
D O I
10.3389/fphy.2023.1124980
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Purpose: Multi-echo Stack-of-stars (SoS) radial k-space trajectories with golden angle ordering are becoming popular for free-breathing abdominal Dixon imaging and proton density fat fraction (PDFF) mapping. Gradient chain imperfections including eddy currents and system delays are known to affect the image quality of radial imaging and to confound the estimation of PDFF mapping. This work proposes a retrospective trajectory correction method based on a simple gradient modulation transfer function (GMTF) measurement to predict and correct gradient chain induced k-space trajectory errors. Methods: The GMTF was measured using the standard hardware of a 3 Tesla scanner on a phantom using the thin slice method and was applied to a 3D radial SoS Dixon imaging sequence. The impact of the GMTF-based correction on image reconstruction and PDFF quantification was investigated using numerical simulations and validated on experimental phantom data as well as on in vivo leg and liver data of healthy volunteers. Results: Correcting the k-space trajectories with the measured GMTF during image reconstruction reduced PDFF quantification errors for phantom and in vivo acquisitions. A Bland-Altman comparison of the measured PDFF phantom and reference data confirmed that the GMTF correction narrowed down the limits of agreement (LoA) from 1.3% +/- 8.1% (uncorrected) to 1.9% +/- 5.4% (GMTF-corrected) over the full PDFF range (0%-100%) and from -0.26% +/- 2.8% (uncorrected) to 0.12% +/- 1.5% (GMTF-corrected) within the 0%-50% PDFF range. Liver PDFF estimation was improved by reducing the standard deviation of the mean liver PDFF and the bias of the mean liver PDFF for all subjects. Conclusion: The proposed GMTF-based k-space trajectory correction is a fast alternative method for avoiding PDFF quantitation errors caused by gradient-system induced k-space trajectory errors in 3D radial multi-echo gradient-echo acquisitions.
引用
收藏
页数:14
相关论文
共 37 条
  • [21] Imaging arterial and venous vessels using Iron Dextran enhanced multi-echo 3D gradient echo MRI at 7T
    Li, Yinghao
    Li, Wei
    Paez, Adrian
    Cao, Di
    Sun, Yuanqi
    Gu, Chunming
    Zhang, Kaihua
    Miao, Xinyuan
    Liu, Peiying
    Li, Wenbo
    Pillai, Jay
    Lu, Hanzhang
    van Zijl, Peter C. M.
    Earley, Christopher
    Li, Xu
    Hua, Jun
    NMR IN BIOMEDICINE, 2024, 37 (12)
  • [22] Fat-Corrected Pancreatic R2* Relaxometry from Multi-Echo Gradient-Recalled Echo Sequence Using Convolutional Neural Network
    Santarelli, Maria Filomena
    Joubbi, Sara
    Meloni, Antonella
    Pistoia, Laura
    Casini, Tommaso
    Massei, Francesco
    Bitti, Pier Paolo
    Allo, Massimo
    Cademartiri, Filippo
    Positano, Vincenzo
    ELECTRONICS, 2022, 11 (18)
  • [23] Simultaneous imaging and R2*mapping using a radial multi-gradient-echo (rMGE) sequence
    Winkelmann, Stefanie
    Schaeffter, Tobias
    Weiss, Steffen
    Eggers, Holger
    Doessel, Olaf
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (04) : 939 - 944
  • [24] Myelin water imaging of in vivo and ex vivo human brains using multi-echo gradient echo at 3T and 7T
    Xu, Guojun
    Zhao, Zhiyong
    Zhu, Qinfeng
    Zhu, Keqing
    Zhang, Jing
    Wu, Dan
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (02) : 803 - 813
  • [25] Magnetic resonance imaging of lung tissue: Influence of body positioning, breathing and oxygen inhalation on signal decay using multi-echo gradient-echo sequences
    Boss, Andreas
    Schaefer, Susanne
    Martirosian, Petros
    Claussen, Claus D.
    Schick, Fritz
    Schaefer, Juergen F.
    INVESTIGATIVE RADIOLOGY, 2008, 43 (06) : 433 - 438
  • [26] Optimized navigator-based correction of breathing-induced B0 field fluctuations in multi-echo gradient-echo imaging of the spinal cord
    Beghini, Laura
    Bueler, Silvan
    Liechti, Martina D.
    Jaffray, Alexander
    David, Gergely
    Vannesjo, S. Johanna
    MAGNETIC RESONANCE IN MEDICINE, 2025,
  • [27] Quantification of liver and muscular fat using contrast-enhanced Dual Source Dual Energy Computed Tomography compared to an established multi-echo Dixon MRI sequence
    Gassenmaier, Sebastian
    Kaehm, Karin
    Walter, Sven S.
    Machann, Juergen
    Nikolaou, Konstantin
    Bongers, Malte N.
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 142
  • [28] Development and validation of a diagnostic nomogram model for osteoporosis in the elderly using 3D multi-echo Dixon sequence combined with magnetization transfer imaging
    Fan, Qiuju
    Tan, Hui
    Zhang, Zhongxu
    Feng, Xingui
    Yu, Nan
    Yu, Yong
    Wang, Shaoyu
    Ma, Guangming
    MAGNETIC RESONANCE IMAGING, 2025, 117
  • [29] Simultaneous pH-sensitive and oxygen-sensitive MRI of human gliomas at 3 T using multi-echo amine proton chemical exchange saturation transfer spin-and-gradient echo echo-planar imaging (CEST-SAGE-EPI)
    Harris, Robert J.
    Yao, Jingwen
    Chakhoyan, Ararat
    Raymond, Catalina
    Leu, Kevin
    Liau, Linda M.
    Nghiemphu, Phioanh L.
    Lai, Albert
    Salamon, Noriko
    Pope, Whitney B.
    Cloughesy, Timothy F.
    Ellingson, Benjamin M.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (05) : 1962 - 1978
  • [30] Non-invasive quantification of hepatic fat content in healthy dogs by using proton magnetic resonance spectroscopy and dual gradient echo magnetic resonance imaging
    Del Chicca, Francesca
    Schwarz, Andrea
    Meier, Dieter
    Grest, Paula
    Liesegang, Annette
    Kircher, Patrick R.
    JOURNAL OF VETERINARY SCIENCE, 2018, 19 (04) : 570 - 576