Data-Driven Tool for Cross-Run Ion Selection and Peak-Picking in Quantitative Proteomics with Data-Independent Acquisition LC-MS/MS

被引:5
|
作者
Yan, Binjun [1 ]
Shi, Mengtian [1 ,2 ]
Cai, Siyu [1 ,2 ]
Su, Yuan [1 ,2 ]
Chen, Renhui [1 ]
Huang, Chiyuan [1 ]
Chen, David Da Yong [3 ]
机构
[1] Chinese Acad Sci, Univ Chinese Acad Sci, Hangzhou Inst Adv Study, Sch Life Sci,Key Lab Syst Biol, Hangzhou 310024, Peoples R China
[2] Zhejiang Chinese Med Univ, Coll Pharmaceut Sci, Hangzhou 310053, Peoples R China
[3] Univ British Columbia, Dept Chem, Vancouver, BC V6T 1Z1, Canada
基金
中国国家自然科学基金;
关键词
MASS-SPECTROMETRY; ALIGNMENT; DIA;
D O I
10.1021/acs.analchem.3c02689
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Proteomics provides molecular bases of biology and disease, and liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a platform widely used for bottom-up proteomics. Data-independent acquisition (DIA) improves the run-to-run reproducibility of LC-MS/MS in proteomics research. However, the existing DIA data processing tools sometimes produce large deviations from true values for the peptides and proteins in quantification. Peak-picking error and incorrect ion selection are the two main causes of the deviations. We present a cross-run ion selection and peak-picking (CRISP) tool that utilizes the important advantage of run-to-run consistency of DIA and simultaneously examines the DIA data from the whole set of runs to filter out the interfering signals, instead of only looking at a single run at a time. Eight datasets acquired by mass spectrometers from different vendors with different types of mass analyzers were used to benchmark our CRISP-DIA against other currently available DIA tools. In the benchmark datasets, for analytes with large content variation among samples, CRISP-DIA generally resulted in 20 to 50% relative decrease in error rates compared to other DIA tools, at both the peptide precursor level and the protein level. CRISP-DIA detected differentially expressed proteins more efficiently, with 3.3 to 90.3% increases in the numbers of true positives and 12.3 to 35.3% decreases in the false positive rates, in some cases. In the real biological datasets, CRISP-DIA showed better consistencies of the quantification results. The advantages of assimilating DIA data in multiple runs for quantitative proteomics were demonstrated, which can significantly improve the quantification accuracy.
引用
收藏
页码:16558 / 16566
页数:9
相关论文
共 50 条
  • [31] Increased Power for the Analysis of Label-free LC-MS/MS Proteomics Data by Combining Spectral Counts and Peptide Peak Attributes
    Dicker, Lee
    Lin, Xihong
    Ivanov, Alexander R.
    MOLECULAR & CELLULAR PROTEOMICS, 2010, 9 (12) : 2704 - 2718
  • [32] Data-independent LC-MS/MS analysis of ME/CFS plasma reveals a dysregulated coagulation system, endothelial dysfunction, downregulation of complement machinery
    Nunes, Massimo
    Vlok, Mare
    Proal, Amy
    Kell, Douglas B.
    Pretorius, Etheresia
    CARDIOVASCULAR DIABETOLOGY, 2024, 23 (01)
  • [33] Comparing Targeted vs. Untargeted MS2 Data-Dependent Acquisition for Peak Annotation in LC-MS Metabolomics
    Ten-Domenech, Isabel
    Martinez-Sena, Teresa
    Moreno-Torres, Marta
    Daniel Sanjuan-Herraez, Juan
    Castell, Jose, V
    Parra-Llorca, Anna
    Vento, Maximo
    Quintas, Guillermo
    Kuligowski, Julia
    METABOLITES, 2020, 10 (04)
  • [34] An Ion Mobility Assisted Data Independent LC-MS Strategy for the Analysis of Complex Biological Samples
    Rodriguez-Suarez, Eva
    Hughes, Chris
    Gethings, Lee
    Giles, Kevin
    Wildgoose, Jason
    Stapels, Martha
    Fadgen, Keith E.
    Geromanos, Scott J.
    Vissers, Johannes P. C.
    Elortza, Felix
    Langridge, James I.
    CURRENT ANALYTICAL CHEMISTRY, 2013, 9 (02) : 199 - 211
  • [35] Variable-Velocity Traveling-Wave Ion Mobility Separation Enhancing Peak Capacity for Data-Independent Acquisition Proteomics
    Haynes, Sarah E.
    Polasky, Daniel A.
    Dixit, Sugyan M.
    Majmudar, Jaimeen D.
    Neeson, Kieran
    Ruotolo, Brandon T.
    Martin, Brent R.
    ANALYTICAL CHEMISTRY, 2017, 89 (11) : 5670 - 5673
  • [36] A Proteomics Pipeline for Generating Clinical Grade Biomarker Candidates from Data-Independent Acquisition Mass Spectrometry (DIA-MS) Discovery
    Fu, Qin
    Vegesna, Manasa
    Sundararaman, Niveda
    Damoc, Eugen
    Arrey, Tabiwang N.
    Pashkova, Anna
    Mengesha, Emebet
    Debbas, Philip
    Joung, Sandy
    Li, Dalin
    Cheng, Susan
    Braun, Jonathan
    McGovern, Dermot P. B.
    Murray, Christopher I.
    Xuan, Yue
    Van Eyk, Jennifer E.
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2024, 63 (52)
  • [37] SILVER: an efficient tool for stable isotope labeling LC-MS data quantitative analysis with quality control methods
    Chang, Cheng
    Zhang, Jiyang
    Han, Mingfei
    Ma, Jie
    Zhang, Wei
    Wu, Songfeng
    Liu, Kehui
    Xie, Hongwei
    He, Fuchu
    Zhu, Yunping
    BIOINFORMATICS, 2014, 30 (04) : 586 - 587
  • [38] Biomedical applications of ion mobility-enhanced data-independent acquisition-based label-free quantitative proteomics
    Distler, Ute
    Kuharev, Joerg
    Tenzer, Stefan
    EXPERT REVIEW OF PROTEOMICS, 2014, 11 (06) : 675 - 684
  • [39] Data-Independent Acquisition-Based Mass Spectrometry (DIA-MS) for Quantitative Analysis of Human Intestinal Ischemia/Reperfusion
    Huang, Anzhong
    Wu, Wei
    Chen, Song
    Hu, Hanbing
    Shen, Jie
    Qie, Jingbo
    Zhong, Ming
    Zhang, Lin
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2022, 194 (9) : 4156 - 4168
  • [40] Data-Independent Acquisition-Based Mass Spectrometry (DIA-MS) for Quantitative Analysis of Human Intestinal Ischemia/Reperfusion
    Anzhong Huang
    Wei Wu
    Song Chen
    Hanbing Hu
    Jie Shen
    Jingbo Qie
    Ming Zhong
    Lin Zhang
    Applied Biochemistry and Biotechnology, 2022, 194 : 4156 - 4168