Complete region of interest reconstruction by fusing multiview deformable three-dimensional transesophageal echocardiography images

被引:0
|
作者
Mao, Zhehua [1 ]
Zhao, Liang [1 ]
Huang, Shoudong [1 ]
Jin, Tongxing [2 ]
Fan, Yiting [3 ]
Lee, Alex Pui-Wai [4 ,5 ]
机构
[1] Univ Technol Sydney, Fac Engn & Informat Technol, Robot Inst, Ultimo, NSW 2007, Australia
[2] Harbin Inst Technol, Sch Informat Sci & Engn, Weihai, Peoples R China
[3] Shanghai Jiao Tong Univ, Shanghai Chest Hosp, Dept Cardiol, Shanghai, Peoples R China
[4] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Med & Therapeut, Div Cardiol, Hong Kong, Peoples R China
[5] Chinese Univ Hong Kong, Fac Med, Li Ka Shing Inst Hlth Sci, Lab Cardiac Imaging & 3D Printing, Hong Kong, Peoples R China
基金
澳大利亚研究理事会;
关键词
3D fusion; direct method; deformation; FoV; TEE; NONRIGID REGISTRATION; ULTRASOUND; MODELS; CT;
D O I
10.1002/mp.15910
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background While three-dimensional transesophageal echocardiography (3D TEE) has been increasingly used for assessing cardiac anatomy and function, it still suffers from a limited field of view (FoV) of the ultrasound transducer. Therefore, it is difficult to examine a complete region of interest without moving the transducer. Existing methods extend the FoV of 3D TEE images by mosaicing multiview static images, which requires synchronization between 3D TEE images and electrocardiogram (ECG) signal to avoid deformations in the images and can only get the widened image at a specific phase. Purpose This work aims to develop a novel multiview nonrigid registration and fusion method to extend the FoV of 3D TEE images at different cardiac phases, avoiding the bias toward the specifically chosen phase. Methods A multiview nonrigid registration and fusion method is proposed to enlarge the FoV of 3D TEE images by fusing dynamic images captured from different viewpoints sequentially. The deformation field for registering images is defined by a collection of affine transformations organized in a graph structure and is estimated by a direct (intensity-based) method. The accuracy of the proposed method is evaluated by comparing it with two B-spline-based methods, two Demons-based methods, and one learning-based method VoxelMorph. Twenty-nine sequences of in vivo 3D TEE images captured from four patients are used for the comparative experiments. Four performance metrics including checkerboard volumes, signed distance, mean absolute distance (MAD), and Dice similarity coefficient (DSC) are used jointly to evaluate the accuracy of the results. Additionally, paired t-tests are performed to examine the significance of the results. Results The qualitative results show that the proposed method can align images more accurately and obtain the fused images with higher quality than the other five methods. Additionally, in the evaluation of the segmented left atrium (LA) walls for the pairwise registration and sequential fusion experiments, the proposed method achieves the MAD of (0.07 +/- 0.03) mm for pairwise registration and (0.19 +/- 0.02) mm for sequential fusion. Paired t-tests indicate that the results obtained from the proposed method are more accurate than those obtained by the state-of-the-art VoxelMorph and the diffeomorphic Demons methods at the significance level of 0.05. In the evaluation of left ventricle (LV) segmentations for the sequential fusion experiments, the proposed method achieves a DSC of (0.88 +/- 0.08), which is also significantly better than diffeomorphic Demons at the 0.05 level. The FoVs of the final fused 3D TEE images obtained by our method are enlarged around two times compared with the original images. Conclusions Without selecting the static (ECG-gated) images from the same cardiac phase, this work addressed the problem of limited FoV of 3D TEE images in the deformable scenario, obtaining the fused images with high accuracy and good quality. The proposed method could provide an alternative to the conventional fusion methods that are biased toward the specifically chosen phase.
引用
收藏
页码:61 / 73
页数:13
相关论文
共 50 条
  • [21] Study on Three Dimensional Reconstruction of Transesophageal Echocardiographic Images
    李治安
    王新房
    陆平
    胡刚
    郑莉慧
    杨娅
    Current Medical Science, 1995, (01) : 10 - 15
  • [22] Three-Dimensional Imaging Methods Based on Multiview Images
    Son, Jung-Young
    Javidi, Bahram
    JOURNAL OF DISPLAY TECHNOLOGY, 2005, 1 (01): : 125 - 140
  • [23] Three-dimensional transesophageal echocardiography reconstruction in acute mechanical mitral valve obstruction during pregnancy
    Reid, Gregory
    Kochlin, Luca
    Santer, David
    Erb, Joachim
    Nestelberger, Thomas
    Grapow, Martin
    Eckstein, Freidrich
    Reuthebuch, Oliver
    WIENER KLINISCHE WOCHENSCHRIFT, 2019, 131 : 403 - 404
  • [24] Three-dimensional imaging in aortic disease by lighthouse transesophageal echocardiography using intravascular ultrasound catheters - Comparison to three-dimensional transesophageal echocardiography and three-dimensional intra-aortic ultrasound imaging
    Buck, T
    Gorge, G
    Hunold, P
    Erbel, R
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1998, 11 (03) : 243 - 258
  • [25] Role of Three-Dimensional Transesophageal Echocardiography in Diagnosis of Coronary Anomalies
    Theron, Alexis
    Jacquier, Alexis
    Ravis, Eleonore
    Ronchard, Thibault
    Gaubert, Jean-Yves
    Grisoli, Dominique
    Gariboldi, Vlad
    Collart, Frederic
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2014, 31 (10): : E317 - E318
  • [26] Applications of three-dimensional transesophageal echocardiography in congenital heart disease
    Jone, Pei-Ni
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2020, 37 (10): : 1665 - 1672
  • [27] A Practical Approach to an Intraoperative Three-Dimensional Transesophageal Echocardiography Examination
    Mahmood, Feroze
    Jeganathan, Jelliffe
    Saraf, Rabya
    Shahul, Sajid
    Swaminathan, Madhav
    Mackensen, G. Burkhard
    Knio, Ziyad
    Matyal, Robina
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2016, 30 (02) : 470 - 490
  • [28] Detection of LV apical thrombus by three-dimensional transesophageal echocardiography
    Fazlinezhad, Afsoon
    Narayanasamy, Hemalatha
    Wilansky, Susan
    Naqvi, Tasneem Z.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2020, 37 (01): : 142 - 146
  • [29] Comparison of transthoracic and transesophageal three-dimensional echocardiography in adult patients
    Godoy, I
    Bednarz, J
    Mor-Avi, V
    Spencer, K
    Lang, R
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 297A - 297A
  • [30] Live three-dimensional transesophageal echocardiography in mitral valve surgery
    MA NingLI ZhianMENG Xu and YANG Ya Department of Ultrasonography Department of Cardiac Surgery Beijing Anzhen HospitalCapital Medical UniversityBeijing China
    中华医学杂志(英文版), 2008, (20) : 2037 - 2041