Usefulness of modular neck adapter in partial hip revision

被引:0
|
作者
Pautasso, Andrea [1 ]
Bardellini, Giuseppe [2 ]
Stissi, Placido [1 ]
D'Angelo, Fabio [1 ,3 ]
机构
[1] ASST Sette Laghi, Circolo Hosp & Macchi Fdn Varese, Univ Ctr, Orthopaed & Traumatol Dept, Viale Luigi Borri 57, I-21100 Varese, Italy
[2] Univ Studies Insubria, Orthopaed & Traumatol Dept, Varese, Italy
[3] Univ Studies Insubria, Dept Biotechnol & Life Sci DBSV, Varese, Italy
来源
ANNALS OF JOINT | 2023年 / 8卷
关键词
Hip revision arthroplasty; head-neck adapter; total hip arthroplasty (THA); Merete BioBall; FEMORAL OFFSET; CERAMIC HEADS; LEG LENGTH; ARTHROPLASTY; RESTORATION; MULTICENTER; FRACTURE;
D O I
10.21037/aoj-23-22
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and Objective: Modular neck adapters allow different length and offset changes to reach a stable total hip arthroplasty (THA) and permit a quick partial hip revision procedure without removing the existing components. The literature is poor on this matter and about the long-term related outcomes. This narrative review summarizes the most recent literature about these devices as an option of surgical treatment in partial total hip arthroplasty revision (THAr) focusing on indications, clinical and radiological outcomes, and related complications. Methods: The narrative review of the current available literature was conducted in December 2022 through electronic database. The terms used were: "Head neck taper" OR "Merete BioBall" AND "revision Total Hip Arthroplasty (MeSH Terms)". The timeframe was limited between 01/01/2000 and 01/12/2022. The studies regarding the clinical use of the Merete BioBall (R) system in hip revision surgery were included, while all the papers concerning modular stem prosthesis were excluded. Key Content and Findings: The surgical procedure is safe, quick and allows the surgeon to correct a well-fixed stem version, length and offset, besides retensioning soft tissues. Clinical and radiological outcomes are good with low complications rates. Conclusions: The modular neck adapter system seems to be a good surgical procedure for recurrent dislocation of THA, especially in case of a second THAr surgery. However, the main indication of adapter use remains the isolated acetabular cup revision. The related complications are rare: the worst is the redislocation due to an insufficient stem version and length correction. Re-dislocation rates reported in literature vary from 5.2% to 15%. Corrosion or fretting of the modular system are not reported in literature.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Usefulness of modular neck adapter in partial hip revision
    Pautasso, Andrea
    Bardellini, Giuseppe
    Stissi, Placido
    D'Angelo, Fabio
    ANNALS OF JOINT, 2023, 8
  • [2] Outcome of a modular head–neck adapter system in revision hip arthroplasty
    Maik Hoberg
    Christian Konrads
    Simon Huber
    Stephan Reppenhagen
    Matthias Walcher
    André Steinert
    Thomas Barthel
    Maximilian Rudert
    Archives of Orthopaedic and Trauma Surgery, 2015, 135 : 1469 - 1474
  • [3] Outcome of a modular head-neck adapter system in revision hip arthroplasty
    Hoberg, Maik
    Konrads, Christian
    Huber, Simon
    Reppenhagen, Stephan
    Walcher, Matthias
    Steinert, Andre
    Barthel, Thomas
    Rudert, Maximilian
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2015, 135 (10) : 1469 - 1474
  • [4] Bioball universal modular neck adapter as a salvage for failed revision total hip arthroplasty
    Vaishya, Raju
    Sharma, Mrinal
    Chaudhary, Rajeev Raj
    INDIAN JOURNAL OF ORTHOPAEDICS, 2013, 47 (05) : 519 - 522
  • [5] A Modular Head-Neck Adapter System and Ceramic Heads in Revision Hip Arthroplasty: A Registry Study on 354 Implants
    Pardo, Francesco
    Castagnini, Francesco
    Bordini, Barbara
    Cosentino, Monica
    Lucchini, Stefano
    Traina, Francesco
    JOURNAL OF ARTHROPLASTY, 2023, 38 (08): : 1578 - 1583
  • [6] Modular neck and ceramic on ceramic coupling in revision total hip arthroplasty
    Pignatti, G.
    Stagni, C.
    Dallari, D.
    Bochicchio, V.
    Raimondi, A.
    Giunti, A.
    BIOCERAMICS AND ALTERNATIVE BEARINGS IN JOINT ARTHROPLASTY, 2006, : 145 - +
  • [7] Revision Hip Arthroplasty Using a Modular Head-Neck Adapter System and a Ceramic Head: 5-Year Clinical and Radiographic Outcomes
    Caternicchia, Filippo
    Fantoni, Valentina
    Poletto, Andrea
    Pardo, Francesco
    Castagnini, Francesco
    Traina, Francesco
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (14)
  • [8] Modular titanium alloy neck adapter failures in hip replacement - failure mode analysis and influence of implant material
    Grupp, Thomas M.
    Weik, Thomas
    Bloemer, Wilhelm
    Knaebel, Hanns-Peter
    BMC MUSCULOSKELETAL DISORDERS, 2010, 11
  • [9] Modular titanium alloy neck adapter failures in hip replacement - failure mode analysis and influence of implant material
    Thomas M Grupp
    Thomas Weik
    Wilhelm Bloemer
    Hanns-Peter Knaebel
    BMC Musculoskeletal Disorders, 11
  • [10] Mid-term outcomes of revision hip arthroplasty due to titanium modular neck failure
    Castagnini, Francesco
    Bordini, Barbara
    Lucchini, Stefano
    Cosentino, Monica
    Tassinari, Enrico
    Traina, Francesco
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (09) : 5909 - 5918