Impact of nocturnal blood pressure dipping on recurrence of atrial fibrillation after pulmonary vein isolation

被引:1
|
作者
Watanabe, Tomonori [1 ]
Hoshide, Satoshi [1 ]
Hachiya, Hitoshi [1 ]
Yumita, Yoshiyuki [1 ]
Sato, Masafumi [1 ]
Mitama, Tadayuki [1 ]
Okuyama, Takafumi [1 ]
Watanabe, Hiroaki [1 ]
Yokota, Ayako [1 ]
Kamioka, Masashi [1 ]
Komori, Takahiro [1 ]
Makimoto, Hisaki [1 ]
Kabutoya, Tomoyuki [1 ]
Imai, Yasushi [1 ]
Kario, Kazuomi [1 ]
机构
[1] Jichi Med Univ, Dept Med, Div Cardiovasc Med, Sch Med, Tochigi, Japan
关键词
Catheter ablation; Blood pressure; Atrial fibrillation; Atrial remodeling; CATHETER ABLATION; ANTIARRHYTHMIC-DRUGS; HEART-FAILURE; RISK-FACTORS; FOLLOW-UP; HYPERTENSION; METAANALYSIS; ASSOCIATION; PREDICTOR; DISEASE;
D O I
10.1038/s41440-024-01645-3
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Lack of the typical nocturnal blood pressure (BP) fall, i.e non-dipper, has been known as a cardiovascular risk. However, the influence of non-dipper on atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI) has been unclear. We investigated the clinical impact of non-dipping as evaluated by 24-hour ambulatory BP monitoring on the long-term outcome of AF recurrence post-PVI in 76 AF patients with a history of increased BP. The PVI procedure was successful in all 76 patients (mean age, 66 +/- 9years; antihypertensive medication, 89%; non-paroxysmal AF, 24%). Twenty patients had AF recurrence during a median follow-up of 1138 days. There was no difference in BP levels between the AF recurrence and non-recurrence groups (average 24 h systolic BP:126 +/- 17 vs.125 +/- 14 mmHg; P = 0.84). On the other hand, the patients with non-dipper had a higher AF recurrence than those with dipper (38.9% vs.15.0%; P = 0.018). In Cox hazard analysis adjusted by age, non-paroxysmal AF and average 24-hr systolic BP level, the non-dipper was an independent predictor of AF recurrence (HR 2.78 [95%CI:1.05-7.34], P = 0.039). Non-dipper patients had a larger left atrial (LA) volume index than the dipper patients (45.9 +/- 17.3 vs.38.3 +/- 10.2 ml/m(2), P = 0.037). Among the 58 patients who underwent high-density voltage mapping in LA, 11 patients had a low-voltage area (LVA) defined as an area with a bipolar voltage < 0.5 mV. However, there was no association of LVA with non-dipper or dipper (22.2% vs.16.1%, P = 0.555). Non-dipper is an independent predictor of AF recurrence post-PVI. Management of abnormal diurnal BP variation post-PVI may be important.
引用
收藏
页码:1688 / 1696
页数:9
相关论文
共 50 条
  • [21] Recurrence of atrial fibrillation after pulmonary vein isolation in dependence of arterial stiffness
    Shchetynska-Marinova, T.
    Kranert, M.
    Baumann, S.
    Liebe, V
    Grafen, A.
    Gerhards, S.
    Rosenkaimer, S.
    Akin, I
    Borggrefe, M.
    Hohneck, A. L.
    NETHERLANDS HEART JOURNAL, 2022, 30 (04) : 198 - 206
  • [22] Impact of unipolar voltage criteria for left atrial posterior wall on atrial fibrillation recurrence after pulmonary vein isolation
    Watanabe, Tomonori
    Watanabe, Hiroaki
    Hachiya, Hitoshi
    Sato, Masafumi
    Mitama, Tadayuki
    Okuyama, Takafumi
    Yokota, Ayako
    Kamioka, Masashi
    Komori, Takahiro
    Kabutoya, Tomoyuki
    Imai, Yasushi
    Kario, Kazuomi
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (04) : 849 - 859
  • [23] Left atrial function parameters as predictors of atrial fibrillation recurrence after pulmonary vein isolation
    Kiliszek, M.
    Uzieblo-Zyczkowska, B.
    Krzyzanowski, K.
    Jurek, A.
    Wierzbowski, R.
    Smalc-Stasiak, M.
    Krzesinski, P.
    EUROPEAN HEART JOURNAL, 2022, 43 : 606 - 606
  • [24] Impact of a prolonged interatrial conduction time for predicting the recurrence of atrial fibrillation after circumferential pulmonary vein isolation of persistent atrial fibrillation
    Satoshi Higuchi
    Koichiro Ejima
    Morio Shoda
    Eri Yamamoto
    Yuji Iwanami
    Daigo Yagishita
    Nobuhisa Hagiwara
    Heart and Vessels, 2019, 34 : 616 - 624
  • [25] Impact of a prolonged interatrial conduction time for predicting the recurrence of atrial fibrillation after circumferential pulmonary vein isolation of persistent atrial fibrillation
    Higuchi, Satoshi
    Ejima, Koichiro
    Shoda, Morio
    Yamamoto, Eri
    Iwanami, Yuji
    Yagishita, Daigo
    Hagiwara, Nobuhisa
    HEART AND VESSELS, 2019, 34 (04) : 616 - 624
  • [26] Modification of the pulmonary vein antrum is associated with recurrence after durable pulmonary vein isolation for paroxysmal atrial fibrillation
    Kujiraoka, Hirofumi
    Hojo, Rintaro
    Arai, Tomoyuki
    Takahashi, Masao
    Fukamizu, Seiji
    Sasano, Tetsuo
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (05) : 1109 - 1116
  • [27] The main reason for recurrence of atrial fibrillation after initially successful pulmonary vein isolation is pulmonary vein reconduction
    Ernst, S
    Ouyang, F
    Baensch, D
    Hachiya, H
    Falk, P
    Schaumann, A
    Antz, M
    Kuck, KH
    EUROPEAN HEART JOURNAL, 2003, 24 : 493 - 493
  • [28] Recurrence of paroxysmal atrial fibrillation after pulmonary vein isolation: is repeat pulmonary vein isolation enough? A prospective, randomized trial
    Fichtner, Stephanie
    Sparn, Korbinian
    Reents, Tilko
    Ammar, Sonia
    Semmler, Verena
    Dillier, Roger
    Buiatti, Alexandra
    Kathan, Susanne
    Hessling, Gabriele
    Deisenhofer, Isabel
    EUROPACE, 2015, 17 (09): : 1371 - 1375
  • [29] Clinical, Electrocardiographic and Echocardiographic Predictors of Atrial Fibrillation Recurrence After Pulmonary Vein Isolation
    Karanikola, Aikaterini-Eleftheria
    Tzortzi, Melpomeni
    Kordalis, Athanasios
    Doundoulakis, Ioannis
    Antoniou, Christos-Konstantinos
    Laina, Ageliki
    Tsioufis, Panagiotis
    Argyriou, Nikos
    Sakalidis, Athanasios
    Pamporis, Konstantinos
    Tsioufis, Konstantinos
    Tsiachris, Dimitrios
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (03)
  • [30] Colchicine Can Reduce Early Recurrence of Atrial Fibrillation after Pulmonary Vein Isolation
    Egami, Yasuyuki
    Nishino, Masami
    Tanouchi, Jun
    Yamada, Yoshio
    CIRCULATION, 2012, 126 (21)