A novel electrochemical biosensing method with double-layered polymer brush modified electrode

被引:4
|
作者
Inoue, Yuuki [1 ]
Kim, Yeji [1 ]
Hasegawa, Hijiri [1 ]
Yoshida, Yasukazu [1 ]
Sakakibara, Keita [2 ,3 ]
Tsujii, Yoshinobu [2 ]
机构
[1] LG Japan Lab Inc, LG Yokohama Innovat Ctr 7F, 1-2-13 Takashima,Nishi Ku, Yokohama, Kanagawa 2200011, Japan
[2] Kyoto Univ, Inst Chem Res, Uji, Kyoto 6110011, Japan
[3] Natl Inst Adv Sci & Technol AIST, Res Inst Sustainable Chem, 3-11-32 Kagamiyama, Higashihiroshima, Hiroshima 7390046, Japan
关键词
Biosensor; Background noise; Polymer brush surface; Double -layered structure; DNA; POLY(ACRYLIC ACID) BRUSHES; TRANSFER RADICAL POLYMERIZATION; PROTEIN ADSORPTION; FUNCTIONAL-GROUPS; BEHAVIOR;
D O I
10.1016/j.colsurfb.2022.113105
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We developed a novel electrochemical biosensor electrode that has a potential to reduce background noise for which we constructed an original conductive substrate modified with a double-layered polymer brush structure that is water impermeable and can control biomolecules adsorption/desorption. In this study, a hydrophobic poly(tert-butyl methacrylate) brush layer was prepared on a gold electrode, and then, the tert-butyl group near the outermost surface was dissociated by the acid treatment to obtain a hydrophilic carboxy group, thereby fabricating a conductive substrate with the double-layered polymer brush structure. Formation of the double -layered polymer brush structure was indicated by surface wettability and optical analyses. The potential dif-ference and hydrogen ion concentration, which is a typical parameter of the surrounding environment, were linearly correlated with the gold electrode having a double-layered polymer brush structure with carboxyl groups. However, there was no correlation on gold electrodes with self-assembled monolayers presenting car -boxy groups. It is considered that the pH responsiveness of the carboxy groups on the outermost surface could be exhibited remarkably because the charge state in the vicinity of the surface became constant due to the hy-drophobic polymer brush layer having a certain thickness. The target DNA could be captured more efficiently at the probe DNA-immobilized electrode with the double-layered polymer brush structure than when using COOH-SAM. This is the first report of the application of the double-layered polymer brush structure for the electro-chemical biosensing, and it will be an excellent surface modification method to reduce background noise.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] A Novel Double-layered Heat Sink for High Power Electronics
    Huang, Yicang
    Xu, Mingliang
    Li, Hui
    Shen, Shengnan
    Ma, Shiyue
    2018 IEEE 20TH ELECTRONICS PACKAGING TECHNOLOGY CONFERENCE (EPTC), 2018, : 686 - 690
  • [22] MODIFIED DOUBLE-LAYERED SUTURING FOR A MUCOSAL DEFECT AFTER COLORECTAL ENDOSCOPIC SUBMUCOSAL DISSECTION (ORIGAMI METHOD)
    Masunaga, Teppei
    Kato, Motohiko
    Sasaki, Motoki
    Iwata, Kentaro
    Miyazaki, Kurato
    Kubosawa, Yoko
    Mizutani, Mari
    Takatori, Yusaku
    Matsuura, Noriko
    Nakayama, Atsushi
    Yahagi, Naohisa
    GASTROINTESTINAL ENDOSCOPY, 2023, 97 (06) : AB155 - AB156
  • [23] AZO/ATO double-layered transparent conducting electrode: A thermal stability study
    Montero, J.
    Guillen, C.
    Herrero, J.
    THIN SOLID FILMS, 2011, 519 (21) : 7564 - 7567
  • [24] rGO/SWCNT composites as novel electrode materials for electrochemical biosensing
    Huang, Tzu-Yen
    Huang, Jen-Hsien
    Wei, Hung-Yu
    Ho, Kuo-Chuan
    Chu, Chih-Wei
    BIOSENSORS & BIOELECTRONICS, 2013, 43 : 173 - 179
  • [25] NBN, NB DOUBLE-LAYERED BASE-ELECTRODE JOSEPHSON-JUNCTIONS
    KOSAKA, S
    KOJIMA, K
    SHINOKI, F
    SHOJI, A
    HAYAKAWA, H
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1982, 21 (01) : 319 - 324
  • [26] Performance-Enhanced Triboelectric Nanogenerator Based on the Double-Layered Electrode Effect
    Jo, Seungju
    Kim, Inkyum
    Jayababu, Nagabandi
    Kim, Daewon
    POLYMERS, 2020, 12 (12) : 1 - 11
  • [27] Peeling Tool: Electrode for Micro-EDM with Coaxially Double-Layered Structure
    Tanabe, Rie
    Seimitsu Kogaku Kaishi/Journal of the Japan Society for Precision Engineering, 2024, 90 (09): : 692 - 695
  • [28] Reversible "Closing" of an Electrode Interface Functionalized with a Polymer Brush by an Electrochemical Signal
    Tam, Tsz Kin
    Pita, Marcos
    Trotsenko, Oleksandr
    Motornov, Mikhail
    Tokarev, Ihor
    Halamek, Jan
    Minko, Sergiy
    Katz, Evgeny
    LANGMUIR, 2010, 26 (06) : 4506 - 4513
  • [29] A novel nonenzymatic electrochemical glucose sensor modified with Ni/Al layered double hydroxide
    Chen, Zhengbo
    Guo, Junxia
    Zhou, Tong
    Zhang, Youwei
    Chen, Liang
    ELECTROCHIMICA ACTA, 2013, 109 : 532 - 535
  • [30] NiFe-Layered Double Hydroxide Sheets as an Efficient Electrochemical Biosensing Platform
    Nesakumar, Noel
    Anantharaj, Sengeni
    Subramanian, Nandhini
    Kundu, Subrata
    Alwarappan, Subbiah
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2018, 165 (11) : B536 - B542