Long-term performance and degradation analysis of a 5 MW solar PV plant in the Andaman & Nicobar Islands

被引:2
|
作者
Mishra, Pushp Rai [1 ]
Rathore, Shanti [2 ]
Varma, K. S. Vishnu [3 ,4 ]
Yadav, Satish Kumar [4 ]
机构
[1] Dr CV Raman Univ, Dept Elect Engn, Bilaspur, India
[2] Dr CV Raman Univ, Dept Elect & Commun Engn, Bilaspur 495113, India
[3] Greenko Grp, Hyderabad 500081, Telangana, India
[4] Univ Lucknow, Ctr Excellence Renewable Energy Educ & Res, Lucknow 226021, India
关键词
Performance analysis; Power plant; Visual defects; Coastal area; Degradation; Algae; PHOTOVOLTAIC POWER-PLANT; GRID-CONNECTED PV; MODULES; CRYSTALLINE; SYSTEM; TECHNOLOGIES;
D O I
10.1016/j.esd.2024.101413
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Renewable energy is being advocated as a new strategy in response to rising energy demand and global climate change. Solar photovoltaic technology is of great significance to climatic conditions due to the good solar intensity and availability to generate energy. In this paper, the 10-year operating performance of a 5 MW solar PV plant installed in tropical climate of the Andaman and Nicobar Islands was analysed. In 2015, the PV plant achieved its highest electricity production of 7216 MWh, while its lowest, 4757 MWh, was observed in 2022.The maximum performance ratio was recorded as 84.28 % in 2016 due to lower operating cell temperature whereas the maximum CUF as 16.17 % was recorded in 2015. The highest module, inverter and system efficiency for the ten year was observed 12.03 %, 97.64 % and 11.75 % respectively in year 2016. In 2014, the highest values for reference yield, array yield, and final yield were recorded as 4.92, 4.08, and 3.98 kWh/kW/day, respectively. Higher capture losses were observed in the plant over the year which varies upto 1.65 h/d. The plant exhibited a degradation rate of 1.99 % per annum, determined by employing an initial PR of 80.03 %, which declined to 64.11 % by 2022. Degradation analysis of the present system was also performed using visual inspection technique. Mostly found defects in plant was corrosion, delamination of encapsulant material, browning of cell material, burn mark on the back of module, milky patterns, cracks in top facing glass and solar cells. Since, the plant is located in the coastal area, it was seen that the plant is facing a severe issue of algae growth. Some PV modules were covered by more than 90 % algae which significantly contribute in capture losses.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] ANALYSIS OF LONG-TERM DDD PERFORMANCE
    KLEMENTOWICZ, P
    OSEROFF, O
    ANDREWS, C
    FURMAN, S
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (05): : 1216 - 1216
  • [32] Real and Simulated Performance Assessment and Tilt Optimization of 5 MW Solar PV Plant Operating Under Tropical Climate of an Indian Island
    Mishra, Pushp Rai
    Kumar, C.H. Kiran
    Strategic Planning for Energy and the Environment, 2024, 43 (04) : 1007 - 1028
  • [33] Long-term performance of an industrial water desalination plant
    Al-Bastaki, N
    Abbas, A
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2004, 43 (04) : 555 - 558
  • [34] TECHNICAL AND ECONOMIC FEASIBIITY STUDY OF A 5 MW SOLAR PHOTOVOLTAIC (PV) POWER PLANT ON KAUAI, HAWAII
    Lee, Kenneth K.
    PROCEEDINGS OF THE ASME POWER CONFERENCE 2008, 2008, : 625 - 630
  • [35] Analysis of Short-Term and Long-Term Characteristics of PV Power Production
    Perez, Marcelo A.
    Zapata, Jaime
    2014 IEEE 23RD INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2014, : 2478 - 2483
  • [36] Analysis on Large-Scale Solar PV Plant Energy Performance-Loss-Degradation in Coastal Climates of India
    Navothna, Bhogula
    Thotakura, Sandhya
    FRONTIERS IN ENERGY RESEARCH, 2022, 10
  • [37] Long-term potential performance degradation analysis method based on dynamical probability model
    Hua, Cheng
    Xu, Guang-Hua
    Zhang, Qing
    Zhang, Yi-Zhuo
    Xie, Jun
    Li, Shu-Zhi
    EXPERT SYSTEMS WITH APPLICATIONS, 2012, 39 (04) : 4410 - 4417
  • [38] Analysis of the Long-Term Performance Degradation of Crystalline Silicon Photovoltaic Modules in Tropical Climates
    Luo, Wei
    Khoo, Yong Sheng
    Hacke, Peter
    Jordan, Dirk
    Zhao, Lu
    Ramakrishna, Seeram
    Aberle, Armin G.
    Reindl, Thomas
    IEEE JOURNAL OF PHOTOVOLTAICS, 2019, 9 (01): : 266 - 271
  • [39] Degradation factor analysis of crystalline-Si PV modules through long-term field exposure test
    Morita, K
    Inoue, T
    Kato, H
    Tsuda, I
    Hishikawa, Y
    PROCEEDINGS OF 3RD WORLD CONFERENCE ON PHOTOVOLTAIC ENERGY CONVERSION, VOLS A-C, 2003, : 1948 - 1951
  • [40] Long-term power degradation analysis of crystalline silicon PV modules using indoor and outdoor measurement techniques
    Carigiet, Fabian
    Brabec, Christoph J.
    Baumgartner, Franz P.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2021, 144