Thermodynamic performance of heat pump with R1234ze(E)/R1336mzz (E) binary refrigerant

被引:9
|
作者
Hu, Hemin [1 ]
Wang, Tao [1 ]
Jiang, Yuyan [3 ]
Bi, Chao [1 ]
Zhang, Bing [1 ]
Fan, Siyi [2 ]
Li, Jianchao [2 ]
An, Siyuan [2 ]
Bai, Xiusen [2 ]
Guo, Cong [3 ]
机构
[1] Beijing Univ Chem Technol, Coll Mech & Elect Engn, Beijing 100029, Peoples R China
[2] Huaneng Beijing Cogenerat Co Ltd, Beijing 100124, Peoples R China
[3] Beijing Inst Technol, Sch Mech Engn, Beijing 100081, Peoples R China
关键词
Heat pump; Binary refrigerant; R1234ze(E); R1336mzz; Thermodynamic performance; Temperature glide; DESIGN-DATA; TEMPERATURE; SYSTEMS; R134A; R718; CO2;
D O I
10.1016/j.applthermaleng.2023.120795
中图分类号
O414.1 [热力学];
学科分类号
摘要
In order to solve the temperature mismatch issue of cold and hot fluids in evaporation and condensation processes for heat pump system, binary refrigerant R1234ze(E)/R1336mzz is recommended in the present research due to its large temperature glide. Through theoretical analysis, multiple configurations under conditions of three different temperature heat sources (70/50 degrees C, 60/40 degrees C and 50/30 degrees C) and two different heat targets (steam above 100 degrees C and hot water with 70 degrees C) are constructed adopted Ebsilon code. The optimum mass proportion is obtained as 0.3/0.7 for R1234ze(E)/R1336mzz(E), because of its maximum temperature glide (can reach 21.52 degrees C) and excellent thermal performance (large COP, ECOP and exergy efficiency). COP of steam high temperature heat pump with R1234ze(E)(0.3)/R1336mzz(E)(0.7) binary refrigerant and the ratio of transferred heat of 110 degrees C condenser to all output heat (containing 110 degrees C and 100 degrees C steam intercooler and condensers) respectively increase up to 67.25% and 335.16% under some certain conditions, compared with that with pure R1336mzz(E). COP of hot water heat pump with R1234ze(E)(0.3)/R1336mzz(E)(0.7) binary refrigerant are respectively 10.31 and 6.89 under 60/40 degrees C and 50/30 degrees C heat source conditions, which greatly increases compared with that of heat pump with pure R1234ze(E) (6.67 and 5.03) and R1336mzz(E) (6.74 and 4.54). The present research may lay a foundation for binary refrigerant adoption to replace the scheme of multi-stage evaporator or multi-stage condenser, which could reduce the irreversible loss of phase change equipment and improve thermodynamic performance of heat pumps.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Vapor-liquid equilibrium modeling for binary system of R152a/R1234ze(E)
    Pan, Chuang
    Dai, Yuande
    Yi, Yiwu
    Liao, Yu
    [J]. CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2023, 62 : 124 - 131
  • [42] R1234yf及R1234ze(E)研究进展概述
    牛永明
    刘军
    周永
    林恩新
    [J]. 制冷与空调, 2015, (11) : 82 - 91
  • [43] Surface tension and liquid viscosity measurement for binary mixtures of R134a with R1234yf and R1234ze(E)
    Bi, Shengshan
    Cui, Junwei
    Zhao, Guanjia
    Wu, Jiangtao
    [J]. FLUID PHASE EQUILIBRIA, 2016, 414 : 60 - 64
  • [44] Numerical research on R32/R1234ze(E) air source heat pump under variable mass concentration
    Cheng, Zuo
    Wang, Baolong
    Shi, Wenxing
    Li, Xianting
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 82 : 1 - 10
  • [45] The Effect of Internal Heat Exchanger Using R1234ze(E) as an Alternative Refrigerant in a Mobile Air-Conditioning System
    Direk, Mehmet
    Soylu, Eren
    [J]. STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2018, 64 (02): : 114 - 120
  • [46] Experimental investigation on boiling heat transfer characteristics of R1234yf/R1336mzz(Z) in horizontal flow
    Liu, Mengtao
    Guo, Li
    Li, Wei
    Xu, Weicong
    Zhao, Li
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 159 : 344 - 355
  • [47] Hazard evaluation of R32/R1234ze(E) cloud explosion
    Liu, Qixuan
    Li, Yanchao
    Gao, Wei
    Zhang, Kai
    Huang, Lei
    Bi, Mingshu
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 111 : 159 - 167
  • [48] Energetic, Economic and Environmental (3E) Optimization of Solar Assisted Heat Pump Using Low GWP Refrigerant R1234ze(E) for High Temperature Application
    Nasruddin, Nasruddin
    Alhamid, M. Idrus
    Aisyah, Nyayu
    [J]. 2017 3RD INTERNATIONAL CONFERENCE ON POWER GENERATION SYSTEMS AND RENEWABLE ENERGY TECHNOLOGIES (PGSRET), 2017, : 79 - 84
  • [49] Investigation on the performance of R1234ze(E) in absorption refrigeration and ejection refrigeration systems
    Bai, Lihang
    Liu, Siqi
    Ye, Zheng
    He, Maogang
    [J]. APPLIED THERMAL ENGINEERING, 2019, 161
  • [50] Hazard evaluation of R32/R1234ze(E) cloud explosion
    Liu, Qixuan
    Li, Yanchao
    Gao, Wei
    Zhang, Kai
    Huang, Lei
    Bi, Mingshu
    [J]. International Journal of Refrigeration, 2020, 111 : 159 - 167