Design, Modeling, and Validation of Grid-Forming Inverters for Frequency Synchronization and Restoration

被引:3
|
作者
Bennia, Ilyas [1 ,2 ]
Elbouchikhi, Elhoussin [3 ]
Harrag, Abdelghani [1 ,2 ]
Daili, Yacine [1 ,2 ]
Saim, Abdelhakim [4 ]
Bouzid, Allal El Moubarek [5 ]
Kanouni, Badreddine [6 ]
机构
[1] Ferhat Abbas Univ Setif 1, Opt & Precis Mech Inst, Mechatron Lab LMETR, Renewable Energy Deployment & Integrat Team, Setif 19000, Algeria
[2] Ferhat Abbas Univ Setif 1, Fac Technol, Electrotech Dept, Setif 19000, Algeria
[3] ISEN Yncrea Ouest, Nantes Campus,LABISEN 33,Ave Champ Manoeuvre, F-44470 Carquefou, France
[4] Univ Nantes, IREENA Lab, F-44600 St Nazaire, France
[5] ICAM Sch Engn, Res & Higher Educ Dept, Toulouse Campus,75 Av Grande Bretagne,CS 97615, F-31076 Toulouse 3, France
[6] Ferhat Abbas Univ Setif 1, Fac Technol, Electrotech Dept, Automat Lab Setif, Setif 19000, Algeria
关键词
grid-forming; microgrid; island mode; droop control; decentralized control; synchronization; frequency restoration; VOLTAGE-SOURCE; OPERATION; POWER; AC;
D O I
10.3390/en17010059
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper focuses on the modeling, analysis, and design of grid-forming (GFM) inverter-based microgrids (MGs). It starts with the development of a mathematical model for three-phase voltage source inverters (VSI). The voltage and current controllers consist of two feedback loops: an outer feedback loop of the capacitance-voltage and an inner feedback loop of the output inductance current. The outer voltage loop is employed to enhance the controller's response time. The inner current loop is used to provide active damping for the resonance created by the LCL filter. A two-layer control scheme is adopted for the GFM inverter control. The primary decentralized control uses droop control and virtual impedance loops to share active and reactive power. Simultaneously, the centralized secondary control addresses frequency and amplitude deviations induced by the droop control. Additionally, a synchronization loop is proposed for seamless reconnection of GFM inverters to the MG and to connect the GFM-controlled MG to the main grid. It has the advantage that the inverter operates in GFM mode even after the synchronization has occurred. The simulation results have shown that the voltage controller ensures a 0.005 s settling time and maintains the steady-state error at its minimum value of 0.1 V. Similarly, the current controller ensures a 0.006 s settling time with a 10-5 steady-state error. The system with the designed controller has a low total harmonic distortion (THD) of 1.46% and improved power quality of the output voltage. Furthermore, a quick restoration time is observed during load steps and tripping events, with a restoration time of 1 s with 10-10 steady-state error. Synchronization is achieved within 0.8 s for the incoming inverters and requires 3 s to synchronize the MG with the main grid, maintaining a steady-state error of 10-9.
引用
收藏
页数:24
相关论文
共 50 条
  • [31] Enhanced Synchronization Stability of Grid-Forming Inverters With Passivity-Based Virtual Oscillator Control
    Kong, Le
    Xue, Yaosuo
    Qiao, Liang
    Wang, Fei
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (12) : 14141 - 14156
  • [32] Global Phase and Magnitude Synchronization of Coupled Oscillators With Application to the Control of Grid-Forming Power Inverters
    Colombino, Marcello
    Gross, Dominic
    Brouillon, Jean-Sebastien
    Dorfler, Florian
    [J]. IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 2019, 64 (11) : 4496 - 4511
  • [33] Design-Oriented Analysis of Grid-Forming Control with Hybrid Synchronization
    Gong, Hong
    Wang, Xiongfei
    [J]. 2022 INTERNATIONAL POWER ELECTRONICS CONFERENCE (IPEC-HIMEJI 2022- ECCE ASIA), 2022, : 440 - 446
  • [34] Control-Sync: A Method for Grid-Forming Inverters
    Sadeque, Fahmid
    Gursoy, Mehmetcan
    Fateh, Fariba
    Mirafzal, Behrooz
    [J]. 2024 IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, APEC, 2024, : 1248 - 1254
  • [35] Control Design of Passive Grid-Forming Inverters in Port-Hamiltonian Framework
    Kong, Le
    Xue, Yaosuo
    Qiao, Liang
    Wang, Fei
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (01) : 332 - 345
  • [36] Dynamic Enhancement of the Droop Control for Grid-Forming Inverters
    Urtasun, Ibai
    Urtasun, Andoni
    Muguiro, Mikel
    Marroyo, Luis
    [J]. 2022 IEEE 23RD WORKSHOP ON CONTROL AND MODELING FOR POWER ELECTRONICS (COMPEL 2022), 2022,
  • [37] Control and Stability of Grid-Forming Inverters: A Comprehensive Review
    Mirmohammad, Marzie
    Azad, Sahar Pirooz
    [J]. ENERGIES, 2024, 17 (13)
  • [38] Physical Insight Into Hybrid-Synchronization-Controlled Grid-Forming Inverters Under Large Disturbances
    Liu, Teng
    Wang, Xiongfei
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (10) : 11475 - 11480
  • [39] Direct AC voltage control for grid-forming inverters
    Taoufik Qoria
    Chuanyue Li
    Ko Oue
    Francois Gruson
    Frederic Colas
    Xavier Guillaud
    [J]. Journal of Power Electronics, 2020, 20 : 198 - 211
  • [40] Direct AC voltage control for grid-forming inverters
    Qoria, Taoufik
    Li, Chuanyue
    Oue, Ko
    Gruson, Francois
    Colas, Frederic
    Guillaud, Xavier