Does a three-hour delayed pushing benefit the mode of delivery?

被引:3
|
作者
Rollet, C. [1 ,2 ]
Chantry, A. A. [2 ,3 ]
Azria, E. [3 ,4 ]
Le Ray, C. [1 ,3 ]
Girault, A. [1 ,3 ]
机构
[1] Univ Paris Cite, Cochin Hosp, AP HP, Port Royal Matern Unit, F-75014 Paris, France
[2] Univ Paris Cite, AP HP, Midwifery Sch Baudelocque, F-75006 Paris, France
[3] Univ Paris Cite, Ctr Res Epidemiol & Stat, Obstet Perinatal & Pediat Epidemiol Res Team EPOPe, CRESS,INSERM,INRA, F-75004 Paris, France
[4] Grp Hosp Paris St Joseph, Matern Unit, Paris, France
关键词
Delayed pushing; Second stage; Labor; Primiparous; Low risk; PROLONGED; 2ND-STAGE; NULLIPAROUS WOMEN; NEONATAL OUTCOMES; 2ND STAGE; LABOR; DURATION; IMMEDIATE; ANALGESIA; MORBIDITY; IMPACT;
D O I
10.1016/j.jogoh.2023.102589
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: The objective of this study was to compare two strategies for passive second stage management: three-hour vs two-hour delayed pushing after the diagnosis of full cervical dilation on mode of delivery and perinatal outcomes.Study Design: This retrospective observational study included low-risk nulliparous women who reatched full cervical dilation under epidural analgesia with a single term fetus in cephalic presentation and normal fetal heart rate, between September and December 2016. Mode of delivery (spontaneous vaginal delivery versus operative delivery including cesarean section and instrumental vaginal delivery) and perinatal outcomes (post-partum hemorrhage, perineal lacerations, 5-min Apgar score, umbilical cord pH and transfer to neona-tal intensive care unit) were compared between two maternity units: maternity unit A, where women could have up to a three-hour delayed pushing period after full cervical dilation diagnosis, and maternity unit B, where the delayed pushing period was a maximum of 2 h. Outcomes were compared using univariate and multivariable analyses. Adjusted odds ratios (aOR) were estimated using a logistic regression multivariable model that included potential cofounders.Results: During the study period, 614 women were included, 305 in maternity unit A and 309 in maternity unit B. Women's pre-existing characteristics were comparable between the two maternity units. Women delivering in the maternity unit A had significantly lower risks of having an operative delivery compared to women delivering in the maternity unit B (respectively 18.4 vs 26.9%; aOR = 0.64; 95%CI [0.43 - 0.96]). Peri-natal outcomes were comparable in the two maternity units, particularly in terms of post-partum hemor-rhage rates (7.4 vs 7.8%; aOR = 1,19 [0.65 -2.19]).Conclusion: Increasing the possible length of the delayed pushing period from 2 to 3 h after the diagnosis of full cervical dilation in low-risk nulliparous women appears to reduce operative deliveries without adverse effects on maternal or neonatal morbidity.(c) 2023 Elsevier Masson SAS. All rights reserved.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Pre-trilostane and three-hour post-trilostane cortisol to monitor trilostane therapy in dogs
    Macfarlane, L.
    Parkin, T.
    Ramsey, I.
    VETERINARY RECORD, 2016, 179 (23) : 597 - +
  • [42] The Three-Hour Lower Body Lift: Evolution of a Technique and Personal Experience after 155 Consecutive Cases
    Maximilian Zaussinger
    Raphael Wenny
    Isabel Zucal
    Clement Staud
    Manfred Schmidt
    Dominik Duscher
    Georg M. Huemer
    Aesthetic Plastic Surgery, 2022, 46 : 1293 - 1302
  • [43] Three-Hour Argon Inhalation Has No Neuroprotective Effect after Open Traumatic Brain Injury in Rats
    Antonova, Viktoriya V.
    Silachev, Denis N.
    Ryzhkov, Ivan A.
    Lapin, Konstantin N.
    Kalabushev, Sergey N.
    Ostrova, Irina, V
    Varnakova, Lydia A.
    Grebenchikov, Oleg A.
    BRAIN SCIENCES, 2022, 12 (07)
  • [44] EARLY EVALUATION OF CMS SEP-1 MEASURE COMPLIANCE AND OUTCOMES: THE THREE-HOUR BUNDLE AND SURVIVAL
    Mackay, Fraser
    Matthews, Lawrence
    Schorr, Christa
    Roy, Aviral
    Crabtree, Pamela
    Hunter, Krystal
    Demetrius, Sherely
    Puri, Nitin
    CRITICAL CARE MEDICINE, 2018, 46 (01) : 720 - 720
  • [45] SEMI-EMPIRICAL CREST DISTRIBUTIONS OF LONG-CREST NONLINEAR WAVES OF THREE-HOUR DURATION
    Huang, Zhenjia
    Guo, Qiuchen
    PROCEEDINGS OF THE ASME 36TH INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE AND ARCTIC ENGINEERING, 2017, VOL 1, 2017,
  • [46] Three-hour spontaneous GH secretion profile is as reliable as oral glucose tolerance test for the diagnosis of acromegaly
    S. Grottoli
    P. Razzore
    D. Gaia
    M. Gasperi
    M. Giusti
    A. Colao
    E. Ciccarelli
    V. Gasco
    E. Martino
    E. Ghigo
    F. Camanni
    Journal of Endocrinological Investigation, 2003, 26 : 123 - 127
  • [47] Does Delayed Pushing in the Second Stage of Labor Impact Perinatal Outcomes?
    Frey, Heather A.
    Tuuli, Methodius G.
    Cortez, Sarah
    Odibo, Anthony O.
    Roehl, Kimberly A.
    Shanks, Anthony L.
    Macones, George A.
    Cahill, Alison G.
    AMERICAN JOURNAL OF PERINATOLOGY, 2012, 29 (10) : 807 - 814
  • [48] The greater Cincinnati t-PA experience alter the NINDS trial: Does a longer time to treatment within the current three-hour window reduce efficacy?
    Kanter, DS
    Kothari, R
    Pancioli, A
    Jauch, E
    Brott, T
    Gebel, J
    Spilker, J
    Liu, TP
    Broderick, J
    STROKE, 1999, 30 (01) : 244 - 244
  • [49] REVISITING THE LITERATURE ON THE "THREE-HOUR WINDOW" GUIDELINE FOR PROGESTIN-ONLY PILLS (POPS): A COMPREHENSIVE SCOPING REVIEW
    Wollum, A.
    Blanchard, K.
    Teal, S. B.
    CONTRACEPTION, 2021, 104 (04) : 465 - 465
  • [50] Three-hour ambulatory blood pressure monitoring: a new surrogate for ambulatory blood pressure assessment in the pakistani population
    Shahab, H.
    Khan, H.
    Tufail, M.
    Almas, A.
    Khan, A. H.
    EUROPEAN HEART JOURNAL, 2020, 41 : 100 - 100