An in vitro model to study suction events by a ventricular assist device: validation with clinical data

被引:3
|
作者
Rocchi, Maria [1 ]
Gross, Christoph [2 ,3 ]
Moscato, Francesco [3 ,4 ,5 ]
Schloeglhofer, Thomas [2 ,3 ,4 ]
Meyns, Bart [1 ,6 ]
Fresiello, Libera [1 ,7 ]
机构
[1] Katholieke Univ Leuven, Dept Cardiovasc Sci, Unit Cardiac Surg, Leuven, Belgium
[2] Med Univ Vienna, Dept Cardiac Surg, Vienna, Austria
[3] Med Univ Vienna, Ctr Med Phys & Biomed Engn, Vienna, Austria
[4] Ludwig Boltzmann Inst Cardiovasc Res, Vienna, Austria
[5] Austrian Cluster Tissue Regenerat, Vienna, Austria
[6] Univ Hosp Leuven, Dept Cardiac Surg, Leuven, Belgium
[7] Univ Twente, Cardiovasc & Resp Physiol, Enschede, Netherlands
基金
奥地利科学基金会;
关键词
ventricular assist device; suction; cardiovascular simulator; hybrid simulator; physiological controllers; validation; PHYSIOLOGICAL CONTROL-SYSTEMS; ROTARY BLOOD PUMPS;
D O I
10.3389/fphys.2023.1155032
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Introduction: Ventricular assist devices (LVADs) are a valuable therapy for end-stage heart failure patients. However, some adverse events still persist, such as suction that can trigger thrombus formation and cardiac rhythm disorders. The aim of this study is to validate a suction module (SM) as a test bench for LVAD suction detection and speed control algorithms.Methods: The SM consists of a latex tube, mimicking the ventricular apex, connected to a LVAD. The SM was implemented into a hybrid in vitro-in silico cardiovascular simulator. Suction was induced simulating hypovolemia in a profile of a dilated cardiomyopathy and of a restrictive cardiomyopathy for pump speeds ranging between 2,500 and 3,200 rpm. Clinical data collected in 38 LVAD patients were used for the validation. Clinical and simulated LVAD flow waveforms were visually compared. For a more quantitative validation, a binary classifier was used to classify simulated suction and non-suction beats. The obtained classification was then compared to that generated by the simulator to evaluate the specificity and sensitivity of the simulator. Finally, a statistical analysis was run on specific suction features (e.g., minimum impeller speed pulsatility, minimum slope of the estimated flow, and timing of the maximum slope of the estimated flow).Results: The simulator could reproduce most of the pump waveforms observed in vivo. The simulator showed a sensitivity and specificity and of 90.0% and 97.5%, respectively. Simulated suction features were in the interquartile range of clinical ones.Conclusions: The SM can be used to investigate suction in different pathophysiological conditions and to support the development of LVAD physiological controllers.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Diversity and dynamics of clinical biofilms in ventricular assist device driveline infections and in vitro modelling
    Qu, Yue
    McGiffin, David
    Peleg, Anton Y.
    MICROBIOLOGY AUSTRALIA, 2023, : 83 - 87
  • [32] In Vitro PET Imaging of a Miniature Ventricular Assist Device
    Gossman, Michael S.
    Graham, Joel D.
    Depot, Stephen
    Zheng, Huaiyu
    Li, Junling
    Ng, Chin K.
    Tamez, Daniel
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2016, 44 (03) : 190 - 194
  • [33] Left Ventricular Hemodynamics with an Implanted Assist Device: An In Vitro Fluid Dynamics Study
    Viola, Francesco
    Jermyn, Elizabeth
    Warnock, James
    Querzoli, Giorgio
    Verzicco, Roberto
    ANNALS OF BIOMEDICAL ENGINEERING, 2019, 47 (08) : 1799 - 1814
  • [34] Left Ventricular Hemodynamics with an Implanted Assist Device: An In Vitro Fluid Dynamics Study
    Francesco Viola
    Elizabeth Jermyn
    James Warnock
    Giorgio Querzoli
    Roberto Verzicco
    Annals of Biomedical Engineering, 2019, 47 : 1799 - 1814
  • [35] Neurologic events with a totally implantable left ventricular assist device: European LionHeart Clinical Utility Baseline Study (CUBS)
    Pae, Walter E.
    Connell, John M.
    Boehmer, John P.
    Korfer, Reiner
    El-Banayosy, Aly
    Hetzer, Roland
    Vigano, Mario
    Pavie, Alain
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2007, 26 (01): : 1 - 8
  • [36] Predicting Right Ventricular Failure Following Left Ventricular Assist Device Support: An INTERMACS Validation Study
    Demertzis, Zachary D.
    Ijaz, Naila
    Taleb, Iosif
    Kyriakopoulos, Christos
    Peruri, Adithya
    Chaudhary, Chris
    Dranow, Elizabeth
    Alharethi, Rami
    Selzman, Craig
    Stehlik, Josef
    Koliopoulou, Antigone
    Tang, Daniel
    Shah, Palak
    Drakos, Stavros
    Cowger, Jennifer
    JOURNAL OF CARDIAC FAILURE, 2022, 28 (05) : S53 - S53
  • [37] In Vitro Benchmarking Study of Ventricular Assist Devices in Current Clinical Use
    Radley, Gemma
    Pieper, Ina Laura
    Robinson, Christian R.
    Ali, Sabrina
    Beshr, Mostafa
    Bodger, Owen
    Thornton, Catherine A.
    JOURNAL OF CARDIAC FAILURE, 2020, 26 (01) : 70 - 79
  • [38] Suction detection in left ventricular assist system: Data fusion approach
    Choi, Seongjin
    International Journal of Control, Automation and Systems, 2003, 1 (03) : 368 - 375
  • [39] Derivation and Validation of a Risk Prediction Model for Waitlist Mortality in Left Ventricular Assist Device Patients
    Tibrewala, A.
    Hu, M.
    Petito, L. C.
    Rich, J.
    Pham, D.
    De By, T.
    Gustafsson, F.
    Veen, K.
    Vanderheyden, M.
    Lloyd-Jones, D.
    Shah, S.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2023, 42 (04): : S237 - S237
  • [40] Clinical experience with the MicroMed DeBakey ventricular assist device
    Noon, GP
    Morley, DL
    Irwin, S
    Abdelsayed, SV
    Benkowski, RJ
    Lynch, BE
    ANNALS OF THORACIC SURGERY, 2001, 71 (03): : S133 - S138