Impacts of electrochemical disinfection on the viability and structure of the microbiome in secondary effluent water

被引:0
|
作者
Yeung, Marvin [1 ]
Tian, Lan [1 ]
Liu, Yuhong [1 ,2 ]
Wang, Hairong [1 ,2 ]
Xi, Jinying [1 ]
机构
[1] Tsinghua Univ, Sch Environm, Environm Simulat & Pollut Control State Key Joint, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Grad Sch Shenzhen, Shenzhen 518055, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrochemical disinfection; Secondary effluent; Microbiome; RNA GENE DATABASE; DRINKING-WATER; PROPIDIUM MONOAZIDE; CHLORINATION; INACTIVATION; RESISTANCE; COMMUNITY;
D O I
10.1007/s11783-024-1818-1
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Electrochemical disinfection (ECD) is a promising disinfection technique for wastewater reclamation; however, the impacts of ECD on the microbiome in secondary effluent wastewater remain unknown. In this study, Propidium monoazide-qPCR (PMA-qPCR) and the plate count method were used to evaluate the inactivation performance, and the PMA-16S rRNA gene sequences of living cells were targeted to study the microbiome. A discrepancy was found between PMA-qPCR and the plate count method in the evaluation of cell count, with increases of 1.5 to 2.2 orders of magnitude in the disinfection rate after 150 s of disinfection. However, the cell count recovered and occasionally exceeded original levels within 3 d after disinfection. Biodiversity was suppressed after ECD, but the microbiome after 150 s disinfection retained a higher level of evenness and stability in the community with a median Shannon index (> 3.7). Pathogenic bacteria remained high in relative abundance even after 150 s of 25 V disinfection, but the biofilm-forming population was effectively suppressed by ECD. The co-occurrence network revealed a centralized and fragile network as disinfection persisted, demonstrating the destabilizing effects of ECD on the microbiome. Functional pathways for cell membrane synthesis and organic compound degradation were enriched after ECD. The reaction of the microbiome after ECD was similar to other disinfection techniques in terms of community structure.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Impacts of virus processing on human norovirus GI and GII persistence during disinfection of municipal secondary wastewater effluent
    Dunkin, Nathan
    Weng, ShihChi
    Coulter, Caroline G.
    Jacangelo, Joseph G.
    Schwab, Kellogg J.
    WATER RESEARCH, 2018, 134 : 1 - 12
  • [22] Water disinfection by electrochemical treatment
    Feng, CP
    Suzuki, K
    Zhao, SY
    Sugiura, N
    Shimada, S
    Maekawa, T
    BIORESOURCE TECHNOLOGY, 2004, 94 (01) : 21 - 25
  • [23] DISINFECTION OF WATER BY ELECTROCHEMICAL TREATMENT
    PATERMARAKIS, G
    FOUNTOUKIDIS, E
    WATER RESEARCH, 1990, 24 (12) : 1491 - 1496
  • [24] Sample Processing Impacts the Viability and Cultivability of the Sponge Microbiome
    Esteves, Ana I. S.
    Amer, Nimra
    Mary Nguyen
    Thomas, Torsten
    FRONTIERS IN MICROBIOLOGY, 2016, 7
  • [25] Ozone provides alternative for secondary effluent disinfection. I
    Nebel, C.
    Gottschling, R.D.
    Unangst, P.C.
    1976, 123 (04): : 76 - 78
  • [26] Modeling of slow sand filtration for disinfection of secondary clarifier effluent
    Langenbach, K.
    Kuschk, P.
    Horn, H.
    Kaestner, M.
    WATER RESEARCH, 2010, 44 (01) : 159 - 166
  • [27] Peracetic acid for secondary effluent disinfection: a comprehensive performance assessment
    Antonelli, M.
    Turolla, A.
    Mezzanotte, V.
    Nurizzo, C.
    WATER SCIENCE AND TECHNOLOGY, 2013, 68 (12) : 2638 - 2644
  • [28] Impacts of solids retention time and antibiotic loading in activated sludge systems on secondary effluent water quality and microbial community structure
    Gerrity, Daniel
    Neyestani, Majid
    WATER ENVIRONMENT RESEARCH, 2019, 91 (06) : 546 - 560
  • [29] Electrochemical alternatives for drinking water disinfection
    Martinez-Huitle, Carlos A.
    Brillas, Enric
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2008, 47 (11) : 1998 - 2005
  • [30] Electrochemical disinfection, an environmentally acceptable method of drinking water disinfection?
    Kerwick, MI
    Reddy, SM
    Chamberlain, AHL
    Holt, DM
    ELECTROCHIMICA ACTA, 2005, 50 (25-26) : 5270 - 5277