Body Composition and Demographic Features Do Not Affect the Diagnostic Accuracy of Shear Wave Elastography

被引:2
|
作者
Varol, Umut [1 ]
Valera-Calero, Juan Antonio [2 ,3 ]
Fernandez-de-las-Penas, Cesar [4 ,5 ]
Buffet-Garcia, Jorge [6 ]
Plaza-Manzano, Gustavo [2 ,3 ]
Navarro-Santana, Marcos Jose [2 ,3 ]
机构
[1] Univ Rey Juan Carlos, Escuela Int Doctorado, Alcorcon 28922, Spain
[2] Univ Complutense Madrid, Fac Nursery, Dept Radiol Rehabil & Physiotherapy, Madrid 28040, Spain
[3] Hosp Clin San Carlos IdISSC, Grp InPhysio, Inst Invest Sanitaria, Madrid 28040, Spain
[4] Univ Rey Juan Carlos, Catedra Inst Docencia, Clin Invest Fisioterapia Terapia Manual Punc Seca, Alcorcon 28922, Spain
[5] Univ Rey Juan Carlos, Dept Phys Therapy Occupat Therapy Rehabil & Phys M, Alcorcon 28922, Spain
[6] Univ Francisco de Vitoria, Fac Hlth Sci, Pozuelo De Alarcon 28223, Spain
来源
BIOENGINEERING-BASEL | 2023年 / 10卷 / 08期
关键词
anterior scalene; diagnostic accuracy study; reliability; shear wave elastography; ultrasonography;
D O I
10.3390/bioengineering10080904
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Shear-wave elastography (SWE) is an imaging method that can be used to estimate shear wave speed and the Young's modulus based on the measured shear wave speed under certain conditions. Up to date, no research has analyzed whether body composition factors contribute to ultrasound attenuation, refraction, reflection, and, consequently, SWE measurement errors. Therefore, this study aimed to analyze the association between demographic and body composition features with SWE errors for assessing the anterior scalene stiffness (which is a key structure in patients with neck pain and nerve compressive syndromes). Demographic (sex, age, height, weight, and body mass index), body composition (water volume, fat mass, and lean mass), and anterior scalene muscle stiffness (Young's modulus and shear wave speed) data were collected from a sample of asymptomatic subjects. After calculating the absolute SWE differences between trials and the reliability estimates, a correlation matrix was generated to quantify the association among all the variables. A total of 34 asymptomatic subjects (24 males) were included in the analyses. Test-retest reliability was excellent for assessing the Young's modulus and shear wave velocity (ICC = 0.912 and 0.923, respectively). No significant associations were found between age, height, weight, body mass index, body fat, lean mass, or water volume with SWE errors (p > 0.05). However, the Young's modulus error was associated with the stiffness properties (p < 0.01), whereas shear wave speed was associated with none of them (all, p > 0.05). A detailed procedure can reliably assess the AS muscle stiffness. None of the sociodemographic or body composition features assessed were correlated with SWE errors. However, baseline stiffness seems to be associated with Young's modulus error.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Visually assessed colour overlay features in shear-wave elastography for breast masses: quantification and diagnostic performance
    Gweon, Hye Mi
    Youk, Ji Hyun
    Son, Eun Ju
    Kim, Jeong-Ah
    [J]. EUROPEAN RADIOLOGY, 2013, 23 (03) : 658 - 663
  • [32] Diagnostic features of quantitative combpush shear elastography for breast lesion differentiation
    Bayat, Mahdi
    Denis, Max
    Gregory, Adriana
    Mehrmohammadi, Mohammad
    Kumar, Viksit
    Meixner, Duane
    Fazzio, Robert T.
    Fatemi, Mostafa
    Alizad, Azra
    [J]. PLOS ONE, 2017, 12 (03):
  • [33] Comparison of the Diagnostic Performance of Strain Elastography and Shear Wave Elastography for the Diagnosis of Carpal Tunnel Syndrome
    Park, Eun Joo
    Hahn, Seok
    Yi, Jisook
    Shin, Kyong Jin
    Lee, Yedaun
    Lee, Ho-Joon
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2021, 40 (05) : 1011 - 1021
  • [34] Diagnostic value of strain elastography and shear wave elastography in differentiating benign and malignant breast lesions
    Shahzad, Rafia
    Fatima, Ismat
    Anjum, Tooba
    Shahid, Abubaker
    [J]. ANNALS OF SAUDI MEDICINE, 2022, 42 (05) : 319 - 326
  • [35] Diagnostic utility of shear wave elastography in musculoskeletal injuries: A narrative review
    Chowdhary, Kuntal
    Raum, George
    Visco, Christopher
    [J]. PM&R, 2024, 16 (04) : 384 - 397
  • [36] Diagnostic Performance of Shear Wave Elastography of the Breast According to Scanning Orientation
    Kim, Solip
    Choi, SeonHyeong
    Choi, Yoonjung
    Kook, Shin-Ho
    Park, Hee Jin
    Chung, Eun Chul
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (10) : 1797 - 1804
  • [37] Diagnostic value of ultrasonic Shear Wave Elastography in Hashimoto's thyroiditis
    Liu, Qiang
    Zhen, Hongxia
    Ding, Kang
    [J]. BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2021, 128 : 196 - 197
  • [38] THE MEASUREMENT OF LIVER STIFFNESS USING LOGIQ S8 SHEAR WAVE ELASTOGRAPHY, ITS RELIABILITY AND DIAGNOSTIC ACCURACY
    Yoo, Jeong-Ju
    Kim, Sang Gyune
    Kim, Young Seok
    [J]. HEPATOLOGY, 2021, 74 : 832A - 832A
  • [39] Diagnostic Accuracy of Integrating Ultrasound and Shear Wave Elastography in Assessing Carpal Tunnel Syndrome Severity: a Prospective Observational Study
    El-Maghraby, Ahmed Mohamed
    Almalki, Yassir Edrees
    Basha, Mohammad Abd Alkhalik
    Nada, Mohamad Gamal
    El Ahwany, Fatma
    Alduraibi, Sharifa Khalid
    Alshehri, Shaker Hassan S.
    Aldhilan, Asim S.
    Almushayti, Ziyad A.
    Alduraibi, Alaa K.
    Aboualkheir, Mervat
    Attia, Osama
    Amer, Mona M.
    Basha, Ahmed M. Abdelkhalik
    Eladi, Ibrahim M.
    [J]. ORTHOPEDIC RESEARCH AND REVIEWS, 2024, 16
  • [40] Diagnostic Performance of Shear Wave Elastography in Patients With Autoimmune Liver Disease
    Li, Changtian
    Dhyani, Manish
    Bhan, Atul K.
    Grajo, Joseph R.
    Pratt, Daniel S.
    Gee, Michael S.
    Samir, Anthony E.
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (01) : 103 - 111