The Influence of Tolerance Gaps on the Fire Performance of Aluminium-Wood Joints

被引:0
|
作者
Sauca, Ana [1 ]
Pope, Ian [1 ]
Frioriksdottir, Hugrun Maria [2 ]
Radulescu, Alexandru [1 ]
Markert, Frank [2 ]
Larsen, Finn [2 ,3 ]
机构
[1] Danish Inst Fire & Secur Technol DBI, Jernholmen 12, DK-2650 Hvidovre, Denmark
[2] Denmarks Tech Univ, Brovej 118, DK-2800 Lyngby, Denmark
[3] Danish Technol Inst DTI, Gregersensvej 1, DK-2630 Taastrup, Denmark
关键词
Engineered timber; Aluminium connectors; Tolerance gaps; Intumescent; Fire protection; Fire resistance;
D O I
10.1007/s10694-023-01504-6
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Tolerance gaps in wood connections are unavoidable, for reasons of constructability and the effects of natural shrinkage in timber elements with changing moisture content. During a fire, these gaps may lead to a substantial heat transfer to the metal connectors that are considered heat protected being embedded by the wooden components of the connection. Aluminium connectors are popular due to their ease of production and assembly, but they are particularly vulnerable to elevated temperatures. This study investigates the effects of tolerance gaps on the fire performance of aluminium connectors in beam-to-column/wall shear connections. Reduced-scale experiments were designed to study the temperature evolution of aluminium connectors during standard fire exposure for 1 mm and 6 mm tolerance gaps, as well the mitigation effects of additional intumescent fire protection in a 6 mm tolerance gap connection. For the 6 mm gap, the temperature of the connector increased much faster, reaching 286 +/- 36 degrees C after 80 min, at which time the connector with a 1 mm gap had only reached 97 +/- 1 degrees C. The addition of intumescent protection in a 6 mm gap case led to lower temperatures in the connection, in comparison to an equivalent tolerance gap without protection. Subsequently, two additional loaded fire tests were performed, for 6 mm and 22 mm tolerance gaps without fire protection, to investigate the critical failure mode of the connectors. In these cases, the failure occurred in the connectors at 87 min and 32 min, respectively, when their average temperatures reached approximately 315 degrees C. This study demonstrates the critical influence of gap size on the fire performance of aluminium-wood joints.
引用
收藏
页码:2621 / 2649
页数:29
相关论文
共 50 条
  • [41] INFLUENCE OF FIRE RETARDANTS ON SMOKE GENERATION FROM WOOD AND WOOD DERIVED MATERIALS.
    Cisek, Tadeusz
    Piechocki, Jacek
    Fire Technology, 1985, 21 (02) : 122 - 133
  • [42] Improvement of fatigue performance by applying tandem GMAW in lap joints with gaps
    Dong-Yoon Kim
    Gwang-Gook Kim
    Jiyoung Yu
    Dongcheol Kim
    Young-Min Kim
    Junhong Park
    The International Journal of Advanced Manufacturing Technology, 2023, 128 : 2123 - 2135
  • [43] The fire and oak hypothesis: Incorporating the influence of deer browsing and canopy gaps
    Collins, RJ
    Carson, WP
    13TH CENTRAL HARDWOOD FOREST CONFERENCE, PROCEEDINGS, 2003, 234 : 44 - 63
  • [44] Influence of Exogenous Silicon Addition on Aluminium Tolerance in Rice Seedlings
    Vijay Pratap Singh
    Durgesh Kumar Tripathi
    Dharmendra Kumar
    Devendra Kumar Chauhan
    Biological Trace Element Research, 2011, 144 : 1260 - 1274
  • [45] Influence of Exogenous Silicon Addition on Aluminium Tolerance in Rice Seedlings
    Singh, Vijay Pratap
    Tripathi, Durgesh Kumar
    Kumar, Dharmendra
    Chauhan, Devendra Kumar
    BIOLOGICAL TRACE ELEMENT RESEARCH, 2011, 144 (1-3) : 1260 - 1274
  • [46] Influence of Silanisation Parameters With γ-Methacryloxypropyltrimethoxysilane on Durability of Aluminium/Acrylic Adhesive Joints
    Del Real, J. C.
    Cano de Santayana, M.
    Abenojar, J.
    Pantoja, M.
    Martinez, M. A.
    JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2008, 22 (13) : 1461 - 1475
  • [47] Experimental investigation of the quantified influence of gypsum plasterboard joints on the fire performance of cold-formed steel walls
    Liu, Kang
    Chen, Wei
    Ye, Jihong
    Gao, Liang
    Jiang, Jian
    STRUCTURES, 2023, 49 : 312 - 331
  • [48] Degradation of shear performance of screwed joints caused by wood decay
    Ueda, Rintaro
    Sawata, Kei
    Takanashi, Ryuya
    Sasaki, Yoshihisa
    Sasak, Takanobu
    JOURNAL OF WOOD SCIENCE, 2020, 66 (01)
  • [49] Performance of CHS T-joints in a standard fire test
    Nguyen, M. P.
    Tan, K. H.
    Fung, T. C.
    TUBULAR STRUCTURES XIV, 2012, : 599 - 606
  • [50] Fire Performance of External Semi-Rigid Composite Joints
    Schaumann, P.
    Zhao, B.
    Bahr, O.
    Renaud, C.
    STRUCTURES IN FIRE: PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE, 2010, : 629 - +