Accuracy of a multipath ultrasonic flowmeter with deep learning based on the velocity profile

被引:0
|
作者
Xu, Zhijia [1 ]
Li, Minghai [1 ]
机构
[1] China Acad Engn Phys, Inst Syst Engn, Mianyang, Sichuan, Peoples R China
关键词
Deep learning; Accuracy; Multipath ultrasonic flowmeter; Double elbow; DATA INTEGRATION; PIPE FLOWS; SIMULATION; CFD;
D O I
10.1108/SR-08-2022-0306
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
PurposeThe asymmetry of the velocity profile caused by geometric deformation, complex turbulent motion and other factors must be considered to effectively use the flowmeter on any section. This study aims to better capture the flow field information and establish a model to predict the profile velocity, we take the classical double elbow as the research object and propose to divide the flow field into three categories with certain common characteristics.Design/methodology/approachThe deep learning method is used to establish the model of multipath linear velocity fitting profile average velocity. A total of 480 groups of data are taken for training and validation, with ten integer velocity flow fields from 1 m/s to 10 m/s. Finally, accuracy research with relative error as standard is carried out.FindingsThe numerical experiment yielded the following promising results: the maximum relative error is approximately 1%, and in the majority of cases, the relative error is significantly lower than 1%. These results demonstrate that it surpasses the classical optimization algorithm Equal Tab (5%) and the traditional artificial neural network (3%) in the same scenario. In contrast with the previous research on a fixed profile, we focus on all the velocity profiles of a certain length for the first time, which can expand the application scope of a multipath ultrasonic flowmeter and promote the research on flow measurement in any section.Originality/valueThis work proposes to divide the flow field of double elbow into three categories with certain common characteristics to better capture the flow field information and establish a model to predict the profile velocity.
引用
收藏
页码:13 / 21
页数:9
相关论文
共 50 条
  • [11] Effects of Velocity Profiles on Measuring Accuracy of Transit-Time Ultrasonic Flowmeter
    Zhang, Hui
    Guo, Chuwen
    Lin, Jie
    APPLIED SCIENCES-BASEL, 2019, 9 (08):
  • [12] MEASURING WATER VELOCITY BY ULTRASONIC FLOWMETER
    SCHUSTER, JC
    JOURNAL OF THE HYDRAULICS DIVISION-ASCE, 1975, 101 (12): : 1503 - 1517
  • [13] Realization of a multipath ultrasonic gas flowmeter based on transit-time technique
    Chen, Qiang
    Li, Weihua
    Wu, Jiangtao
    ULTRASONICS, 2014, 54 (01) : 285 - 290
  • [14] An adaptive weighted integration method for multipath ultrasonic flowmeter
    Guo, Suna
    Han, Jiawen
    Li, Baonan
    Fang, Lide
    Zhang, Tao
    Wang, Fan
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2024, 35 (11)
  • [15] ASYMMETRIC FLOW VELOCITY MEASUREMENT USING MULTIPATH ULTRASONIC FLOWMETER WITH ADAPTIVE WEIGHTING METHOD GUIDED BY TOMOGRAPHY
    Amri, Khairul
    Suprijanto
    Kurniadi, Deddy
    Juliastuti, Endang
    JURNAL TEKNOLOGI, 2020, 82 (01): : 135 - 146
  • [16] Ultrasonic Tomographic Flowmeter using Dual-Transducers for the Reconstruction of an Asymmetric Velocity Profile
    Amri, K.
    Suprijanto
    Juliastuti, E.
    Kurniadi, D.
    PROCEEDINGS OF THE 2016 INTERNATIONAL CONFERENCE ON INSTRUMENTATION, CONTROL, AND AUTOMATION (ICA), 2016, : 184 - 188
  • [17] Support Vector Regression-Based Data Integration Method for Multipath Ultrasonic Flowmeter
    Zhao, Huichao
    Peng, Lihui
    Takahashi, Tsuyoshi
    Hayashi, Takuya
    Shimizu, Kazuyoshi
    Yamamoto, Toshihiro
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2014, 63 (12) : 2717 - 2725
  • [18] STUDIES ON VELOCITY BLOOD FLOW WITH ULTRASONIC FLOWMETER
    RAM, MD
    BHIMANI, BK
    SURGERY GYNECOLOGY AND OBSTETRICS WITH INTERNATIONAL ABSTRACTS OF SURGERY, 1971, 133 (05): : 815 - &
  • [20] ULTRASONIC BLOOD FLOWMETER YIELDING INSTANTANEOUS VELOCITY PROFILE BY REAL-TIME PHASE DETECTION
    BRANDESTINI, M
    ELECTRONICS LETTERS, 1975, 11 (08) : 183 - 184