Design and fabrication of a long-term stable model eye for OCT retinal imaging

被引:1
|
作者
Okubo, Takuro [1 ]
Mino, Toshihiro [1 ]
机构
[1] Topcon Corp, Div Res & Dev, Itabashi Ku, Tokyo 1748580, Japan
关键词
optical coherence tomography; phantom; fluorosilicone; OCULAR FUNDUS TISSUES; OPTICAL-PROPERTIES;
D O I
10.1117/12.2647489
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
We propose a long-term stable model eye with three-layered retinal phantom. The layers are made of fluorosilicone which refractive index is 1.38 and includes fine particles of TiO2 or polystyrene. The particle mixing amount is determined with respect to haze for each layer to achieve OCT images resemble to those of human retina. Stable liquid of fluorinated oil is filled in vitreous-mimic cavity. In addition, high-temperature durability test indicates that the model eye has high stability for more than six years. We have successfully obtained OCT images of the model eye, which are comparable to those of human eyes.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Multi-Functional OCT for Long-Term Study of Retinal Changes in a VLDLR Mouse Model
    Augustin, Marco
    Fialova, Stanislava
    Plasenzotti, Roberto
    Pircher, Michael
    Hitzenberger, Christoph K.
    Baumann, Bernhard
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [2] Long-term Live Imaging of Drosophila Eye Disc
    Tsao, Chia-Kang
    Ku, Hui-Yu
    Sun, Y. Henry
    [J]. JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2017, (123):
  • [3] Fabrication of a MEMS retinal tack and long-term in vivo biocompatibility evaluation for retinal prostheses
    Lee, Sangmin
    Ko, Hyoungho
    [J]. MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2017, 23 (02): : 483 - 489
  • [4] Fabrication of a MEMS retinal tack and long-term in vivo biocompatibility evaluation for retinal prostheses
    Sangmin Lee
    Hyoungho Ko
    [J]. Microsystem Technologies, 2017, 23 : 483 - 489
  • [5] Concurrent electrophysiology and TPM/OCT imaging of long-term implanted electrodes
    Hammer, Daniel X.
    Gao, Yu-Rong
    Ye, Meijun
    Welle, Cristin G.
    [J]. NEURAL IMAGING AND SENSING, 2017, 10051
  • [6] A CANINE MODEL FOR LONG-TERM STUDY OF RETINAL PERFUSION
    CAPOZZI, DK
    REHKOPF, PG
    FRIBERG, TR
    WARNICKI, JW
    FINEGOLD, DN
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 862 - 862
  • [7] Rapid laser fabrication of long-term stable superhydrophilic aluminum surface
    Zhao, Jingnan
    Nie, Xihan
    Guo, Jian
    Zhang, Yan
    Wang, Yan
    Cui, Yuanchen
    Shrotriya, Pranav
    [J]. SN APPLIED SCIENCES, 2020, 2 (04)
  • [8] Rapid laser fabrication of long-term stable superhydrophilic aluminum surface
    Jingnan Zhao
    Xihan Nie
    Jian Guo
    Yan Zhang
    Yan Wang
    Yuanchen Cui
    Pranav Shrotriya
    [J]. SN Applied Sciences, 2020, 2
  • [9] Long-term stable measurement phantoms for magnetic particle imaging
    Woeckel, Lucas
    Wells, James
    Kosch, Olaf
    Lyer, Stefan
    Alexiou, Christoph
    Gruettner, Cordula
    Wiekhorst, Frank
    Dutz, Silvio
    [J]. JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2019, 471 : 1 - 7
  • [10] An Implantable retinal stimulator design for long-term animal experiments
    Zhou, J. A.
    Park, S. I.
    Seo, J. M.
    Lee, S. W.
    Kim, E. T.
    Chung, H.
    Kim, S. J.
    [J]. WORLD CONGRESS ON ENGINEERING 2007, VOLS 1 AND 2, 2007, : 1451 - +