Experimental Approach for Clarifying Initiation and Growth Behaviors of Internal Fatigue Cracks Using Synchrotron Radiation Multiscale X-ray Computed Tomography

被引:2
|
作者
Nakamura, Takashi [1 ]
Xue, Gaoge [2 ]
Kon, Yuma [2 ]
Fujimura, Nao [1 ]
Yamazaki, Takuya [2 ]
Tonozaki, Nobuyuki [3 ]
Takeuchi, Akihisa [4 ]
Uesugi, Masayuki [4 ]
Uesugi, Kentaro [4 ]
机构
[1] Hokkaido Univ, Div Mech & Aerosp Engn, North 13, West 8, Kita Ku, Sapporo, Hokkaido 0608628, Japan
[2] Hokkaido Univ, Div Mech & Space Engn, North 13, West 8, Kita Ku, Sapporo, Hokkaido 0608628, Japan
[3] Yamamoto Engn Ltd, 3-1-1 Tenjin, Otaru, Hokkaido 0470011, Japan
[4] Japan Synchrotron Radiat Res Inst JASRI, SPring 8, 1-1-1 Kouto, Sayo, Hyogo 6795198, Japan
基金
日本学术振兴会;
关键词
very high cycle fatigue; tomography; internal crack; nondestructive inspection; synchrotron radiation; titanium alloy steel; HIGH-CYCLE FATIGUE; TITANIUM-ALLOY; TI-6AL-4V; STEEL; MECHANISM; MICROSTRUCTURE; PREDICTION; LIMIT; LIFE;
D O I
10.1520/MPC20230023
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The very high cycle fatigue (VHCF) phenomenon has been recognized and extensively studied in the past quarter century. One of the most peculiar and noticeable characteristics of VHCF is the transition of the origin site from the surface to the interior of the material in long-life regimes over 107 cycles. In particular, in high-strength metals, a tiny site can become an origin of internal fatigue cracks, such as nonmetallic inclusions of several micrometers to several tens of micrometers in high-strength steels and crystal grains of several tens of micrometers in titanium alloys. However, such small cracks are difficult to detect using conventional nondestructive approaches, such as industrial X-ray computed tomography (CT) or ultrasonic CT. Given this background, we have attempted to use a synchrotron radiation multiscale X-ray CT provided by SPring-8 in Japan. This system comprises a projection CT (micro-CT) with a spatial resolution of approximately 1 mu m and a phase-contrast imaging CT (nano-CT) with a spatial resolution of approximately 200 nm or higher. The present study introduces our experimental approach to clarify internal fatigue crack behaviors using the multiscale X-ray CT with in situ fatigue testing. First, the principle of material selection focusing on the VHCF study is explained with the details of the materials used: (alpha+beta) type Ti-6Al-4V, beta type Ti-22V-4Al, and 17-4 precipitation-hardened martensite stainless steel. Afterward, the outline and primary performance of the multiscale X-ray CT are described. Subsequently, important points in conducting accurate in situ fatigue tests are discussed from the viewpoints of the development policies of the testing system and preparation of the special thin specimen for CT imaging. Finally, the multi-scale X-ray CT is conducted for the above materials, and the initiation and growth behaviors of the internal fatigue cracks are compared and discussed for an in-depth understanding of the VHCF phenomenon.
引用
收藏
页码:107 / 128
页数:22
相关论文
共 50 条
  • [21] Initiation and growth behaviour of small internal fatigue cracks in Ti-6Al-4V via synchrotron radiation microcomputed tomography
    Yoshinaka, Fumiyoshi
    Nakamura, Takashi
    Takeuchi, Akihisa
    Uesugi, Masayuki
    Uesugi, Kentaro
    FATIGUE & FRACTURE OF ENGINEERING MATERIALS & STRUCTURES, 2019, 42 (09) : 2093 - 2105
  • [22] Experimental investigation of junction growth of rough contacts using X-ray computed tomography
    Wang, Runliang
    Liu, Jianhua
    Liu, Bo
    Jia, Duo
    Ding, Xiaoyu
    FRICTION, 2024, 12 (11) : 2519 - 2531
  • [23] Initiation and Growth of Pits and Cracks in Corrosion Fatigue for High Strength Aluminium Alloy Observed by Micro Computed-tomography Using Ultra-bright Synchrotron Radiation
    Nakai, Yoshikazu
    Shiozawa, Daiki
    EXPERIMENTAL MECHANICS AND MATERIALS, 2011, 83 : 162 - 167
  • [24] Determination of Density Distribution of Tablets Using Synchrotron X-ray Computed Tomography
    Takayama, Kozo
    Otoguro, Saori
    Okada, Nobuto
    Hoshino, Masato
    Yagi, Naoto
    Obata, Yasuko
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 2017, 137 (06): : 757 - 762
  • [25] Combined X-ray fluorescence and absorption computed tomography using a synchrotron beam
    Hall, C.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [26] New types of X-ray computed tomography (CT) with synchrotron radiation: Fluorescent X-ray CT and phase-contrast X-ray CT using interferometer
    Takeda, T
    Momose, A
    Yu, QW
    Yuasa, T
    Dilmanian, FA
    Akatsuka, T
    Itai, Y
    CELLULAR AND MOLECULAR BIOLOGY, 2000, 46 (06) : 1077 - 1088
  • [27] In situ analysis of cracks in structural materials using synchrotron X-ray tomography and diffraction
    Steuwer, A
    Edwards, L
    Pratihar, S
    Ganguly, S
    Peel, M
    Fitzpatrick, ME
    Marrow, TJ
    Withers, PJ
    Sinclair, I
    Singh, KD
    Gao, N
    Buslaps, T
    Buffière, JY
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2006, 246 (01): : 217 - 225
  • [29] A new approach to synchrotron energy-dispersive X-ray diffraction computed tomography
    Lazzari, Olivier
    Egan, Christopher K.
    Jacques, Simon D. M.
    Sochi, Taha
    Di Michiel, Marco
    Cernik, Robert J.
    Barnes, Paul
    JOURNAL OF SYNCHROTRON RADIATION, 2012, 19 : 471 - 477
  • [30] OBSERVATION OF INNER FIBERS IN METAL MATRIX COMPOSITES BY X-RAY COMPUTED-TOMOGRAPHY USING SYNCHROTRON RADIATION
    TANAKA, Y
    MASUDA, C
    USAMI, K
    HIRANO, T
    IMAI, Y
    SHIOTA, I
    FURUBAYASHI, E
    IWASAKI, H
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1992, 78 (03): : 500 - 507