Theoretical analysis of the attenuation characteristics of high-frequency pressure vibration in pumped storage power station

被引:3
|
作者
Yang, Xiuwei [1 ,2 ,3 ]
Lian, Jijian [1 ,2 ,3 ]
Zhang, Ziliang [1 ,2 ]
Zeng, Yonghong [1 ,2 ,3 ]
机构
[1] Tianjin Univ, State Key Lab Hydraul Engn Simulat & Safety, Tianjin 300350, Peoples R China
[2] Tianjin Univ, Sch Civil Engn, Tianjin 300350, Peoples R China
[3] Technol Innovat Ctr Hydropower Wind Solar & Energy, Tibet 850000, Peoples R China
关键词
Fluid -filled pipe; Fluid -dominate wave; Coupling model; Attenuation characteristics; High -frequency pressure fluctuation; Pumped storage power station; CIRCULAR LINED TUNNEL; FLUID-STRUCTURE INTERACTION; IMPERFECT INTERFACE; DYNAMIC-RESPONSE; LOAD REJECTION; HYDRO; INCLUSION; BEHAVIOR; SYSTEM; WAVES;
D O I
10.1016/j.est.2023.108341
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
High-frequency vibration is a common hydraulic phenomenon in pumped storage power station. In this study, a theoretical model for analyzing the high-frequency vibration in fluid-pipe-surrounding support coupling system is established. The discontinuity characteristics between the pipe wall and surrounding medium are modeled by the linear spring model, where axial and radial spring constants represent the bounding degree of the pipe and surrounding support. The relation between the wave speed and attenuation characteristics of the high-frequency vibration could be derived from the established theoretical model. And a strategy for estimating the attenuation rate of the high-frequency vibration is proposed. According to the theoretical analysis results, the connection and transition of the vibration energy through the pipe and surrounding support mainly rely on radial bounding. With decreasing in the compressibility of the pipe wall and the surrounding medium, the attenuation rate of high-frequency decreases. One of the reasons why the high-frequency pressure vibration could propagate over long distances in the pumped storage power station may be attributed to the little compressibility of the solid structures in the headrace tunnel.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Mid- and high-frequency vibration characteristics of track structures
    Lei X.-Y.
    Xing C.-C.
    Wu S.-H.
    Zhendong Gongcheng Xuebao/Journal of Vibration Engineering, 2020, 33 (06): : 1245 - 1252
  • [42] Excavation of a large egg-shaped underground cavern for a pumped storage power station under high ground pressure
    Kudo, K
    Koyama, T
    Nanbu, S
    Akoshima, T
    TUNNELS FOR PEOPLE, VOLS 1 AND 2, 1997, : 841 - 846
  • [43] HIGH-FREQUENCY ULTRASONIC ATTENUATION IN HE-II UNDER PRESSURE
    JAECKLE, J
    KEHR, KW
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1971, 16 (04): : 615 - &
  • [44] SINGLE-STATION ATTENUATION MEASUREMENTS OF HIGH-FREQUENCY RAYLEIGH-WAVES IN SCOTLAND
    MACBETH, CD
    BURTON, PW
    GEOPHYSICAL JOURNAL OF THE ROYAL ASTRONOMICAL SOCIETY, 1987, 89 (03): : 757 - 797
  • [45] High-frequency characteristics of high-voltage power line
    Suljanovic, N
    Mujcic, A
    Zajc, M
    Tasic, JF
    IEEE REGION 8 EUROCON 2003, VOL B, PROCEEDINGS: COMPUTER AS A TOOL, 2003, : 310 - 314
  • [46] Modeling and application analysis of optimal joint operation of pumped storage power station and wind power
    Xu, Fei
    Chen, Lei
    Jin, Heping
    Liu, Zhenhua
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2013, 37 (01): : 149 - 154
  • [47] High-frequency magnetic properties and attenuation characteristics for barium ferrite composites
    Li, Z. W.
    Lin, G. Q.
    Wu, Y. P.
    Kong, L. B.
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2009, 321 (07) : 734 - 737
  • [48] Research on Fractional Order PID Control of Regional Load Frequency of Pumped Storage Power Station
    Shan H.
    He J.
    Fan L.
    Gao C.
    Mei R.
    Luo Z.
    Dianwang Jishu/Power System Technology, 2020, 44 (04): : 1410 - 1418
  • [49] ANALYSIS OF THE CHARACTERISTICS OF PLANAR POWER MAGNETICS FOR HIGH-FREQUENCY DC/DC CONVERTERS
    SAKAKIBARA, K
    ELECTRONICS AND COMMUNICATIONS IN JAPAN PART II-ELECTRONICS, 1994, 77 (02): : 105 - 113
  • [50] Active Disturbance Rejection Controller Optimization of Load Frequency in Interconnected Power Grid With Pumped Storage Power Station
    Yang Y.
    Xiang L.
    Guo X.
    Zheng Y.
    Dianwang Jishu/Power System Technology, 2021, 45 (01): : 276 - 283