Supercooling behaviours of thermoelectric coolers with different continuous Double-pulse current waveforms

被引:2
|
作者
Gao, Yan-Wei [1 ]
Shi, Cong-Ling [1 ]
Che, Hong-Lei [1 ]
Han, Song [1 ]
机构
[1] China Acad Safety Sci & Technol, Beijing 100012, Peoples R China
关键词
Thermoelectric coolers; Transient supercooling performance; Numerical simulation; Effective cold-holding time; PERFORMANCE; DEVICES; MODULE;
D O I
10.1016/j.applthermaleng.2023.120766
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study innovatively identifies techniques to improve the transient supercooling performance of thermo-electric coolers (TECs) through continuous double-pulse currents with different waveforms. Some applications need to operate at a specific temperature while obtaining the requirement for long periods of refrigeration, thus the new effective cold-holding time (teff-hold) for the defined effective cooling line and the variation curve of the cold-end temperature was used as the main index to measure the transient performance of the TEC. In addition, the cold-end minimum temperature (Tc,min), overshoot temperature (Tc,max), and the time for recovery to steady-state temperature (trec) of TEC were considered comprehensively. A three-dimensional (3D) multi-physics coupling transient model was constructed using numerical simulations, and its accuracy was verified by experimental data. Five typical pulse waveforms (-t  2, -t1/2, t0, t1/2, and t2) were used as the research objects. The results demonstrated that the waveform of the continuous double-pulse current plays an important role in improving the teff-hold of TECs under transient working conditions. In this simulation, the pulse widths (r1 and r2) of the first and second pulse currents were both 4 s when the pulse initial current was the optimal current (0.6A). When the pulse amplitudes (P1 and P2) were equal and small, the pulse current combination of t0 + t1/2 was applied, which could achieve relatively large teff-hold values. However,-t2 + t1/2 was more appropriate. Addi-tionally, large teff-hold values for TECs could be achieved by reasonably choosing the pulse widths (r1 and r2) and amplitudes (P1 and P2) of continuous double-pulse waveforms and the initial current of the second pulse current (Iini,2). It is important to ensure that P1 is not too large, or it may lead to significant increases in Tc,min and Tc,max, a growth in trec, and a reduction in teff-hold. In this study, the optimal teff-hold was achieved (8.38 s) when the pulse current combination was-t2 + t1/2, P1 = 4, P2 = 3, r1 = r2 = 4 s, and Iini,2 = 0.55A.
引用
收藏
页数:12
相关论文
共 38 条
  • [31] Motor thresholds in humans: a transcranial magnetic stimulation study comparing different pulse waveforms, current directions and stimulator types
    Kammer, T
    Beck, S
    Thielscher, A
    Laubis-Herrmann, U
    Topka, H
    CLINICAL NEUROPHYSIOLOGY, 2001, 112 (02) : 250 - 258
  • [32] Study of material ablation and plasma radiation in double-pulse laser induced breakdown spectroscopy at different delay times: Modeling and numerical simulation
    Nosrati, Y.
    Tavassoli, S. H.
    Hassanimatin, M. M.
    Safi, A.
    PHYSICS OF PLASMAS, 2020, 27 (02)
  • [33] Enhancement of optical emission generated from femtosecond double-pulse laser-induced glass plasma at different sample temperatures in air
    王莹
    陈安民
    王秋云
    张丹
    隋来志
    李苏宇
    姜远飞
    金明星
    Plasma Science and Technology, 2019, 21 (03) : 102 - 111
  • [34] Orthogonal double-pulse versus single-pulse laser ablation at different air pressures: A comparison of the mass removal mechanisms (vol 64, pg 29, 2009)
    Cristoforetti, Gabriele
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (09) : 928 - 928
  • [35] Enhancement of optical emission generated from femtosecond double-pulse laser-induced glass plasma at different sample temperatures in air
    王莹
    陈安民
    王秋云
    张丹
    隋来志
    李苏宇
    姜远飞
    金明星
    Plasma Science and Technology, 2019, (03) : 102 - 111
  • [36] Enhancement of optical emission generated from femtosecond double-pulse laser-induced glass plasma at different sample temperatures in air
    Wang, Ying
    Chen, Anmin
    Wang, Qiuyun
    Zhang, Dan
    Sui, Laizhi
    Li, Suyu
    Jiang, Yuanfei
    Jin, Mingxing
    PLASMA SCIENCE & TECHNOLOGY, 2019, 21 (03)
  • [37] CONTINUOUS REGISTRATION OF MEMBRANE INPUT RESISTANCES OF SMALL PLANT-CELLS USING A DOUBLE-PULSE CURRENT CLAMP TECHNIQUE FOR SINGLE-ELECTRODE IMPALEMENTS - COMPARISON WITH THE CONVENTIONAL 2-ELECTRODE METHOD
    SCHEFCZIK, K
    SIMONIS, W
    SCHIEBE, M
    PLANT PHYSIOLOGY, 1983, 72 (02) : 368 - 375
  • [38] Preclinical comparative examinations of different laser systems for lithotripsy of common bile duct stones including a new frequency-doubled double-pulse neodymium YAG-laser (FREDDY)
    Tex, S
    Maiss, J
    Magdeburg, B
    Neizamy, E
    Hahn, E
    Hochberger, J
    GASTROINTESTINAL ENDOSCOPY, 2002, 55 (05) : AB170 - AB170