Supercooling behaviours of thermoelectric coolers with different continuous Double-pulse current waveforms

被引:2
|
作者
Gao, Yan-Wei [1 ]
Shi, Cong-Ling [1 ]
Che, Hong-Lei [1 ]
Han, Song [1 ]
机构
[1] China Acad Safety Sci & Technol, Beijing 100012, Peoples R China
关键词
Thermoelectric coolers; Transient supercooling performance; Numerical simulation; Effective cold-holding time; PERFORMANCE; DEVICES; MODULE;
D O I
10.1016/j.applthermaleng.2023.120766
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study innovatively identifies techniques to improve the transient supercooling performance of thermo-electric coolers (TECs) through continuous double-pulse currents with different waveforms. Some applications need to operate at a specific temperature while obtaining the requirement for long periods of refrigeration, thus the new effective cold-holding time (teff-hold) for the defined effective cooling line and the variation curve of the cold-end temperature was used as the main index to measure the transient performance of the TEC. In addition, the cold-end minimum temperature (Tc,min), overshoot temperature (Tc,max), and the time for recovery to steady-state temperature (trec) of TEC were considered comprehensively. A three-dimensional (3D) multi-physics coupling transient model was constructed using numerical simulations, and its accuracy was verified by experimental data. Five typical pulse waveforms (-t  2, -t1/2, t0, t1/2, and t2) were used as the research objects. The results demonstrated that the waveform of the continuous double-pulse current plays an important role in improving the teff-hold of TECs under transient working conditions. In this simulation, the pulse widths (r1 and r2) of the first and second pulse currents were both 4 s when the pulse initial current was the optimal current (0.6A). When the pulse amplitudes (P1 and P2) were equal and small, the pulse current combination of t0 + t1/2 was applied, which could achieve relatively large teff-hold values. However,-t2 + t1/2 was more appropriate. Addi-tionally, large teff-hold values for TECs could be achieved by reasonably choosing the pulse widths (r1 and r2) and amplitudes (P1 and P2) of continuous double-pulse waveforms and the initial current of the second pulse current (Iini,2). It is important to ensure that P1 is not too large, or it may lead to significant increases in Tc,min and Tc,max, a growth in trec, and a reduction in teff-hold. In this study, the optimal teff-hold was achieved (8.38 s) when the pulse current combination was-t2 + t1/2, P1 = 4, P2 = 3, r1 = r2 = 4 s, and Iini,2 = 0.55A.
引用
收藏
页数:12
相关论文
共 38 条
  • [1] Transient supercooling performance of thermoelectric coolers with a continuous double current pulse
    Wang, Shuo-Lin
    Liu, Hai-Bo
    Gao, Yan-Wei
    Shen, Yuan
    Yang, Yan-Ru
    Wang, Xiao-Dong
    Lee, Duu-Jong
    JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2021, 120 : 127 - 135
  • [2] An investigation on thermoelectric coolers operated with continuous current pulses
    Ma, Ming
    Yu, Jianlin
    Chen, Jiaheng
    ENERGY CONVERSION AND MANAGEMENT, 2015, 98 : 275 - 281
  • [3] Thermal-electric and stress analysis of thermoelectric coolers under continuous pulse input current
    Fan, Shifa
    Rezania, Alireza
    Gao, Yuanwen
    APPLIED THERMAL ENGINEERING, 2022, 214
  • [4] Optimal pulse current shape for transient supercooling of thermoelectric cooler
    Lv, Hao
    Wang, Xiao-Dong
    Wang, Tian-Hu
    Meng, Jing-Hui
    ENERGY, 2015, 83 : 788 - 796
  • [5] Pulse electrodeposition of platinum catalyst using different pulse current waveforms
    Karimi, Shahram
    Foulkes, Frank R.
    ELECTROCHEMISTRY COMMUNICATIONS, 2012, 19 : 17 - 20
  • [6] PRECONDITIONED WIRE ARRAY Z-PINCH ON A DOUBLE-PULSE CURRENT GENERATOR
    Wu, Jian
    Lu, YiHan
    Zhang, Daoyuan
    Li, Xingwen
    Jia, Shenli
    Qiu, Aici
    2017 IEEE INTERNATIONAL CONFERENCE ON PLASMA SCIENCE (ICOPS), 2017,
  • [7] Pulse Current Electrodeposition of Nanocatalysts Using Different Waveforms for Use in PEMFCs
    Karimi, Shahram
    NOVEL DESIGN AND ELECTRODEPOSITION MODALITIES, 2013, 53 (11): : 59 - 67
  • [8] FAST TRANSIENT-BEHAVIOR OF THERMOELECTRIC COOLERS WITH HIGH-CURRENT PULSE AND FINITE COLD JUNCTION
    FIELD, RL
    BLUM, HA
    ENERGY CONVERSION, 1979, 19 (03): : 159 - 165
  • [9] Numerical analysis for transient supercooling effect of pulse current shapes on a two-stage thermoelectric cooler
    Gao, Yan-Wei
    Shi Cong-Ling
    Wang Xiao-Dong
    APPLIED THERMAL ENGINEERING, 2019, 163
  • [10] Different effects of double-pulse TMS of the posterior parietal cortex on reflexive and voluntary saccades
    Kapoula, Zoi
    Yang, Qing
    Sabbah, Norman
    Vernet, Marine
    FRONTIERS IN HUMAN NEUROSCIENCE, 2011, 5