Real-time measurement of stapes motion and intracochlear pressure during blast exposure

被引:3
|
作者
Bien, Alexander G. [1 ,2 ]
Jiang, Shangyuan [1 ]
Gan, Rong Z. [1 ,3 ]
机构
[1] Univ Oklahoma, Sch Aerosp & Mech Engn, Norman, OK USA
[2] Univ Oklahoma, Dept Otolaryngol Head & Neck Surg, Med Ctr, Oklahoma City, OK USA
[3] Univ Oklahoma, Sch Aerosp & Mech Engn, Biomed Engn, 865 Asp Ave,Room 200, Norman, OK 73019 USA
关键词
Intracochlear pressure; Stapes footplate; Energy entering the cochlea; Blast overpressure; Laser Doppler vibrometry; IMPULSE NOISE; BIOMECHANICAL MEASUREMENT; INJURY; OVERPRESSURE; TRANSMISSION; PREDICTION; TEMPORARY; DAMAGE; LEVEL;
D O I
10.1016/j.heares.2023.108702
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Blast-induced auditory injury is primarily caused by exposure to an overwhelming amount of energy transmitted into the external auditory canal, the middle ear, and then the cochlea. Quantification of this energy requires real-time measurement of stapes footplate (SFP) motion and intracochlear pressure in the scala vestibuli (Psv). To date, SFP and Psv have not been measured simultaneously during blast exposure, but a dual-laser experimental approach for detecting the movement of the SFP was reported by Jiang et al. (2021). In this study, we have incorporated the measurement of Psv with SFP motion and developed a novel approach to quantitatively measure the energy flux entering the cochlea during blast exposure. Five fresh human cadaveric temporal bones (TBs) were used in this study. A mastoidectomy and facial recess approach were performed to identify the SFP, followed by a cochleostomy into the scala vestibuli (SV). The TB was mounted to the "head block ", a fixture to simulate a real human skull, with two pressure sensors - one inserted into the SV (Psv) and another in the ear canal near the tympanic membrane (P1). The TB was exposed to the blast overpressure (P0) around 4 psi or 28 kPa. Two laser Doppler vibrometers (LDVs) were used to measure the movements of the SFP and TB (as a reference). The LDVs, P1, and Psv signals were triggered by P0 and recorded simultaneously. The results include peak values for Psv of 100.8 +/- 51.6 kPa (mean +/- SD) and for SFP displacement of 72.6 +/- 56.4 mu m, which are consistent with published experimental results and finite element modeling data. Most of the P0 input energy flux into the cochlea occurred within 2 ms and resulted in 10-70 mu J total energy entering the cochlea. Although the middle ear pressure gain was close to that measured under acoustic stimulus conditions, the nonlinear behavior of the middle ear was observed from the elevated cochlear input impedance. For the first time, SFP movement and intracochlear pressure Psv have been successfully measured simultaneously during blast exposure. This study provides a new methodology and experimental data for determining the energy flux entering the cochlea during a blast, which serves as an injury index for quantifying blast-induced auditory damage.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Real-Time Intracochlear Electrocochleography Obtained Directly Through a Cochlear Implant
    Harris, Michael S.
    Riggs, William Jason
    Koka, Kanthaiah
    Litvak, Leonid M.
    Malhotra, Prashant
    Moberly, Aaron C.
    O'Connell, Brendan P.
    Holder, Jourdan
    Alberto Di Lella, Federico
    Mario Boccio, Carlos
    Wanna, George B.
    Labadie, Robert F.
    Adunka, Oliver F.
    OTOLOGY & NEUROTOLOGY, 2017, 38 (06) : E107 - E113
  • [32] Dynamic intracochlear pressure measurement during cochlear implant electrode insertion
    Ordonez, F.
    Riemann, C.
    Mueller, S.
    Sudhoff, H.
    Todt, I
    ACTA OTO-LARYNGOLOGICA, 2019, 139 (10) : 860 - 865
  • [33] Real-time measurement and audit of radiation exposure to patients in computed radiography
    Vano, E
    Fernandez, J
    Ten, J
    Guibelalde, E
    Pedrosa, CS
    RADIOLOGY, 2000, 217 : 403 - 403
  • [34] Robust Brightness Measurement and Exposure Control in Real-Time Video Recording
    Kao, Wen-Chung
    Cheng, Li-Wei
    Chien, Chen-Yu
    Lin, Wen-Kuo
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2011, 60 (04) : 1206 - 1216
  • [35] Real-time method for the measurement of noise exposure from communication headsets
    Dajani, H
    Kunov, H
    Seshagiri, B
    APPLIED ACOUSTICS, 1996, 49 (03) : 209 - 224
  • [36] Real-time measurement of radiation exposure to patients during diagnostic coronary angiography and percutaneous interventional procedures
    Cusma, JT
    Bell, MR
    Wondrow, MA
    Taubel, JP
    Holmes, DR
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (02) : 427 - 435
  • [37] Real-time measurement of stave thickness in a blast furnace using sacrificial ultrasonic waveguide
    Agrawal, Rohit Kumar
    Shunmugasundaram, Rajendran
    Indimath, Shivanandan
    Sahara, Taher Mohammed
    Reddy, Bonikila Pradeep
    Pratap, Vikrant
    Balamurugan, Srinivasagan
    IRONMAKING & STEELMAKING, 2022, 49 (01) : 29 - 41
  • [38] REAL-TIME MEASUREMENT OF IMPEDANCE SPECTRA DURING CORROSION FATIGUE
    ONO, M
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1984, 70 (13): : 1437 - 1437
  • [39] Real-time measurement of skin radiation during cardiac catheterization
    Hwang, E
    Gaxiola, E
    Vlietstra, RE
    Brenner, A
    Ebersole, D
    Browne, K
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1998, 43 (04): : 367 - 370
  • [40] AUDITING REAL-TIME MEASUREMENT
    GARDNER, B
    GLAZEBROOK, TJ
    MORRISON, WR
    RYAN, WH
    WILLIAMS, ML
    AGA 1989 OPERATING SECTION PROCEEDINGS, 1989, : 513 - 519