Dental Root Injuries Caused by Osteosynthesis Screws in Orthognathic Surgery-Comparison of Conventional Osteosynthesis and Osteosynthesis by CAD/CAM Drill Guides and Patient-Specific Implants

被引:1
|
作者
Pietzka, Sebastian [1 ,2 ]
Fink, Juliana [1 ]
Winter, Karsten [3 ]
Wilde, Frank [1 ,2 ]
Schramm, Alexander [1 ,2 ]
Ebeling, Marcel [2 ]
Kasper, Robin [2 ]
Sakkas, Andreas [1 ,2 ]
机构
[1] Univ Hosp Ulm, Dept Craniomaxillofacial Surg, D-89081 Ulm, Germany
[2] German Armed Forces Hosp, Dept Craniomaxillofacial Surg, D-89081 Ulm, Germany
[3] Univ Leipzig, Inst Anat, Med Fac, D-04109 Leipzig, Germany
来源
JOURNAL OF PERSONALIZED MEDICINE | 2023年 / 13卷 / 05期
关键词
orthognathic surgery; iatrogenic dental root injuries; patient-specific implant; osteosynthesis screws; virtual planning; computer assisted surgery; INTERMAXILLARY FIXATION; DAMAGE; COMPLICATIONS; EXPERIENCE; TEMPLATES; OSTEOTOMY; ACCURACY; SPLINTS; BONE;
D O I
10.3390/jpm13050706
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background/Aim: The primary aim was to evaluate the prevalence and localisation of dental injuries caused by osteosynthesis screws during orthognathic surgery, comparing two different CAD/CAM planning/surgical approaches through retrospective evaluation of post-operative computed tomography. Material and Methods: This study considered all patients who underwent orthognathic surgery from 2010-2019. The examination for dental root injuries between conventional osteosynthesis (Maxilla conventional cohort) and osteosynthesis with patient-specific implant (Maxilla PSI cohort) was performed by evaluating the post-operative CT scans. Results: A total of 126 patients were included in the study. Among the 61 patients of the Maxilla conventional cohort, 10 dental root injuries in 8 patients (13.1%) were detected in the post-operative CT scan, representing 1.5% (n = 10/651) of the osteosynthesis screws inserted in proximity of the alveolar crest. No dental injury occurred following osteosynthesis in the 65 patients of the Maxillary PSI cohort (n = 0/773 screws) (p < 0.001). During a mean follow-up period of 13 months after primary surgery, none of the injured teeth showed evidence of periapical alterations and no endodontic treatments were necessary. Conclusions: Maxillary positioning using CAD/CAM-fabricated drill/osteotomy guide and osteosynthesis with PSI can significantly reduce the risk for dental injury compared to the conventional procedure. However, the clinical significance of the detected dental injuries was rather minor.
引用
收藏
页数:16
相关论文
共 7 条
  • [1] Splintless surgery: does patient-specific CAD-CAM osteosynthesis improve accuracy of Le Fort I osteotomy?
    Kraeima, J.
    Jansma, J.
    Schepers, R. H.
    [J]. BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2016, 54 (10): : 1085 - 1089
  • [2] Clinical accuracy of waferless maxillary positioning using customized surgical guides and patient specific osteosynthesis in bimaxillary orthognathic surgery
    Heufelder, Marcus
    Wilde, Frank
    Pietzka, Sebastian
    Mascha, Frank
    Winter, Karsten
    Schramm, Alexander
    Rana, Majeed
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2017, 45 (09) : 1578 - 1585
  • [3] Custom made cutting guides and osteosynthesis plates versus CAD/CAM occlusal splints in positioning and fixation of the maxilla in orthognathic surgery: A prospective randomized study
    Sanchez-Jauregui, Eduardo
    Baranda-Manterola, Elena
    Ranz-Colio, Alvaro
    Bueno de Vicente, Angela
    Acero-Sanz, Julio
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2022, 50 (08) : 609 - 614
  • [4] Randomized Clinical Trial of the Accuracy of Patient-Specific Implants versus CAD/CAM Splints in Orthognathic Surgery
    Li, Biao
    Wei, Hongpu
    Jiang, Tengfei
    Qian, Yifeng
    Zhang, Tianjia
    Yu, Hongbo
    Zhang, Lei
    Wang, Xudong
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2021, 148 (05): : 1101 - 1110
  • [5] Development of patient-specific osteosynthesis including 3D-printed drilling guides for medial tibial plateau fracture surgery
    Nick Assink
    Miriam G. E. Oldhoff
    Kaj ten Duis
    Joep Kraeima
    Job N. Doornberg
    Max J. H. Witjes
    Jean-Paul P. M. de Vries
    Anne M. L. Meesters
    Frank F. A. IJpma
    [J]. European Journal of Trauma and Emergency Surgery, 2024, 50 : 11 - 19
  • [6] Development of patient-specific osteosynthesis including 3D-printed drilling guides for medial tibial plateau fracture surgery
    Assink, Nick
    Oldhoff, Miriam G. E.
    ten Duis, Kaj
    Kraeima, Joep
    Doornberg, Job N.
    Witjes, Max J. H.
    de Vries, Jean-Paul P. M.
    Meesters, Anne M. L.
    IJpma, Frank F. A.
    [J]. EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2024, 50 (01) : 11 - 19
  • [7] Precision of orthognathic digital plan transfer using patient-specific cutting guides and osteosynthesis versus mixed analogue-digitally planned surgery: a randomized controlled clinical trial
    Hanafy, M.
    Akoush, Y.
    Abou-ElFetouh, A.
    Mounir, R. M.
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2020, 49 (01) : 62 - 68