Development of patient-specific osteosynthesis including 3D-printed drilling guides for medial tibial plateau fracture surgery

被引:3
|
作者
Assink, Nick [1 ,2 ]
Oldhoff, Miriam G. E. [1 ,2 ]
ten Duis, Kaj [1 ]
Kraeima, Joep [2 ]
Doornberg, Job N. [1 ]
Witjes, Max J. H. [2 ]
de Vries, Jean-Paul P. M. [3 ]
Meesters, Anne M. L. [1 ,2 ]
IJpma, Frank F. A. [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Trauma Surg, HPC BA13,Hanzepl 1, NL-9713 GZ Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, 3D Lab, Groningen, Netherlands
[3] Univ Med Ctr Groningen, Dept Surg, Groningen, Netherlands
关键词
Tibial plateau fracture; Medial tibial plateau; Three-dimensional; 3D printing; Virtual surgical planning; Guided surgery; Patient-specific implant; PSI; FIT;
D O I
10.1007/s00068-023-02313-w
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
PurposeA substantial proportion of conventional tibial plateau plates have a poor fit, which may result in suboptimal fracture reduction due to applied -uncontrolled- compression on the bone. This study aimed to assess whether patient-specific osteosyntheses could facilitate proper fracture reduction in medial tibial plateau fractures.MethodsIn three Thiel embalmed human cadavers, a total of six tibial plateau fractures (three Schatzker 4, and three Schatzker 6) were created and CT scans were made. A 3D surgical plan was created and a patient-specific implant was designed and fabricated for each fracture. Drilling guides that fitted on top of the customized plates were designed and 3D printed in order to assist the surgeon in positioning the plate and steering the screws in the preplanned direction. After surgery, a postoperative CT scan was obtained and outcome was compared with the preoperative planning in terms of articular reduction, plate positioning, and screw direction.ResultsA total of six patient-specific implants including 41 screws were used to operate six tibial plateau fractures. Three fractures were treated with single plating, and three fractures with dual plating. The median intra-articular gap was reduced from 6.0 (IQR 4.5-9.5) to 0.9 mm (IQR 0.2-1.4), whereas the median step-off was reduced from 4.8 (IQR 4.1-5.3) to 1.3 mm (IQR 0.9-1.5). The median Euclidean distance between the centre of gravity of the planned and actual implant was 3.0 mm (IQR: 2.8-3.7). The lengths of the screws were according to the predetermined plan. None of the screws led to screw penetration. The median difference between the planned and actual screw direction was 3.3 & DEG; (IQR: 2.5-5.1).ConclusionThis feasibility study described the development and implementation of a patient-specific workflow for medial tibial plateau fracture surgery that facilitates proper fracture reduction, tibial alignment and accurately placed screws by using custom-made osteosynthesis plates with drilling guides.
引用
收藏
页码:11 / 19
页数:9
相关论文
共 50 条
  • [1] Development of patient-specific osteosynthesis including 3D-printed drilling guides for medial tibial plateau fracture surgery
    Nick Assink
    Miriam G. E. Oldhoff
    Kaj ten Duis
    Joep Kraeima
    Job N. Doornberg
    Max J. H. Witjes
    Jean-Paul P. M. de Vries
    Anne M. L. Meesters
    Frank F. A. IJpma
    [J]. European Journal of Trauma and Emergency Surgery, 2024, 50 : 11 - 19
  • [2] 3D-printed Patient-specific Guides for Hip Arthroplasty
    Henckel, Johann
    Holme, Thomas J.
    Radford, Warwick
    Skinner, John A.
    Hart, Alister J.
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2018, 26 (16) : E342 - E348
  • [3] 3D surgical planning including patient-specific drilling guides for tibial plateau fractures a prospective feasibility study
    Assink, N.
    ten Duis, K.
    de Vries, J. P. M.
    Witjes, M. J. H.
    Kraeima, J.
    Doornberg, J. N.
    Ijpma, F. F. A.
    [J]. BONE & JOINT OPEN, 2024, 5 (01): : 46 - 52
  • [4] Patient-specific 3D-printed glioblastomas
    Gomez-Roman, Natividad
    Chalmers, Anthony J.
    [J]. NATURE BIOMEDICAL ENGINEERING, 2019, 3 (07) : 498 - 499
  • [5] Patient-specific 3D-printed glioblastomas
    Natividad Gomez-Roman
    Anthony J. Chalmers
    [J]. Nature Biomedical Engineering, 2019, 3 : 498 - 499
  • [6] Corrective osteotomies using patient-specific 3D-printed guides: a critical appraisal
    Rosseels, Wouter
    Herteleer, Michiel
    Sermon, An
    Nijs, Stefaan
    Hoekstra, Harm
    [J]. EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2019, 45 (02) : 299 - 307
  • [7] Corrective osteotomies using patient-specific 3D-printed guides: a critical appraisal
    Wouter Rosseels
    Michiel Herteleer
    An Sermon
    Stefaan Nijs
    Harm Hoekstra
    [J]. European Journal of Trauma and Emergency Surgery, 2019, 45 : 299 - 307
  • [8] Clinical Experience Using a 3D-Printed Patient-Specific Instrument for Medial Opening Wedge High Tibial Osteotomy
    Yang, Jesse Chieh-Szu
    Chen, Cheng-Fong
    Luo, Chu-An
    Chang, Ming-Chau
    Lee, Oscar K.
    Huang, Ye
    Lin, Shang-Chih
    [J]. BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [9] Patient-specific desktop 3D-printed guides for pelvic tumour resection surgery: a precision study on cadavers
    Mónica García-Sevilla
    Lydia Mediavilla-Santos
    María Teresa Ruiz-Alba
    Rubén Pérez-Mañanes
    José Antonio Calvo-Haro
    Javier Pascau
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2021, 16 : 397 - 406
  • [10] Patient-specific desktop 3D-printed guides for pelvic tumour resection surgery: a precision study on cadavers
    Garcia-Sevilla, Monica
    Mediavilla-Santos, Lydia
    Ruiz-Alba, Maria Teresa
    Perez-Mananes, Ruben
    Calvo-Haro, Jose Antonio
    Pascau, Javier
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2021, 16 (03) : 397 - 406