Postprandial splenic stiffness changes on magnetic resonance elastography in a young healthy population

被引:1
|
作者
Obrzut, Marzanna [1 ]
Atamaniuk, Vitaliy [2 ,7 ]
Ehman, Richard L. [3 ]
Yin, Meng [3 ]
Cholewa, Marian [2 ]
Gutkowski, Krzysztof [4 ]
Domka, Wojciech [5 ]
Obrzut, Bogdan [6 ]
机构
[1] Univ Rzeszow, Inst Hlth Sci, Med Coll, Rzeszow, Poland
[2] Univ Rzeszow, Coll Nat Sci, Inst Phys, Dept Biophys, Rzeszow, Poland
[3] Mayo Clin, Dept Radiol, Rochester, MN USA
[4] Univ Rzeszow, Inst Med Sci, Med Coll, Rzeszow, Poland
[5] Univ Rzeszow, Inst Med Sci, Med Coll, Dept Otolaryngol, Rzeszow, Poland
[6] Univ Rzeszow, Inst Med Sci, Dept Obstet & Gynecol, Med Coll, Rzeszow, Poland
[7] Univ Rzeszow, Inst Phys, Coll Nat Sci, Dept Biophys, A0 Bldg B1, room 314, Prof Stanislawa Pigonia str, PL-35310 Rzeszow, Poland
关键词
magnetic resonance elastography; tissue stiffness; MR ELASTOGRAPHY; ESOPHAGEAL-VARICES; PORTAL-HYPERTENSION; LIVER; SPLEEN; CIRRHOSIS;
D O I
10.1002/nbm.5047
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Magnetic resonance elastography (MRE) is an accurate noninvasive diagnostic tool for assessing the stiffness of parenchymal organs, including the spleen. However, this measurement may be biased due to postprandial changes in splenic stiffness. The aim of the current study was to evaluate postprandial changes in spleen stiffness assessed by MRE in a large sample of healthy volunteers. This was a prospective institutional research ethics board-approved study. Healthy volunteers with no history of liver disease were recruited for an MRE test and blood draw from December 2018 to July 2019. Each participant underwent spleen MRE after at least 4 h of fasting and again 30 min after a 1000 kcal meal. Also, 14 randomly selected volunteers underwent additional MRE examinations at 1.5 and 2.5 h after food intake. The MRE data were acquired at 60 Hz using a 1.5-T MRI scanner. The spleen stiffness was assessed using a weighted mean of stiffness values from regions of interest manually drawn on three to five spleen slices. Spearman's rank correlation, Wilcoxon signed-rank, Friedman, and Mann-Whitney tests were used for statistical analysis. A total of 100 volunteers met the inclusion criteria and were eventually enrolled in this study (age 23 +/- 2 years; 65 women). The mean spleen stiffness for the whole group increased by 7.9% (p < 0.001) from the mean +/- SD value of 5.09 +/- 0.63 (95% CI: 4.96-5.21) kPa in the fasting state to 5.47 +/- 0.66 (95% CI 5.34-5.60) kPa 30 min after the meal and then gradually decreased. However, even 2 h 30 min after the meal, the spleen stiffness was higher than in the fasting state. This difference was statistically significant at p less than 0.001. It was concluded that meal intake results in a statistically significant elevation of spleen stiffness that persists for 2.5 h. This finding supports the recommendation for routine fasting for more than 2.5 h prior to assessing MRE-based spleen stiffness.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Preoperative assessment of meningioma stiffness using magnetic resonance elastography
    Murphy, Matthew C.
    Huston, John, III
    Glaser, Kevin J.
    Manduca, Armando
    Meyer, Fredric B.
    Lanzino, Giuseppe
    Morris, Jonathan M.
    Felmlee, Joel P.
    Ehman, Richard L.
    JOURNAL OF NEUROSURGERY, 2013, 118 (03) : 643 - 648
  • [32] Magnetic resonance elastography for assessment of testicular stiffness in patients with varicocele Testis MR elastography
    Pocan, Suheyl
    Karakas, Levent
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2023, 14 : 325 - 329
  • [33] Postprandial decrease in splenic volume demonstrated by magnetic resonance imaging and stereology
    Betal, D
    Hughes, ML
    Whitehouse, GH
    Roberts, N
    CLINICAL ANATOMY, 2000, 13 (06) : 404 - 409
  • [34] Magnetic resonance elastography can monitor changes in medullary stiffness in response to treatment in the swine ischemic kidney
    Zhang, Xin
    Zhu, Xiangyang
    Ferguson, Christopher Martyn
    Jiang, Kai
    Burningham, Tyson
    Lerman, Amir
    Lerman, Lilach Orly
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2018, 31 (03): : 375 - 382
  • [35] Magnetic resonance elastography can monitor changes in medullary stiffness in response to treatment in the swine ischemic kidney
    Xin Zhang
    Xiangyang Zhu
    Christopher Martyn Ferguson
    Kai Jiang
    Tyson Burningham
    Amir Lerman
    Lilach Orly Lerman
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2018, 31 : 375 - 382
  • [36] Assessment of regional aortic stiffness with cardiac magnetic resonance imaging in a healthy Asian population
    Eun Kyoung Kim
    Sung-A Chang
    Shin Yi Jang
    Yiseul Kim
    Sung Mok Kim
    Jae K. Oh
    Yeon Hyeon Choe
    Duk-Kyung Kim
    The International Journal of Cardiovascular Imaging, 2013, 29 : 57 - 64
  • [37] Assessment of regional aortic stiffness with cardiac magnetic resonance imaging in a healthy Asian population
    Kim, Eun Kyoung
    Chang, Sung-A
    Jang, Shin Yi
    Kim, Yiseul
    Kim, Sung Mok
    Oh, Jae K.
    Choe, Yeon Hyeon
    Kim, Duk-Kyung
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 : 57 - 64
  • [38] Liver stiffness measurement by magnetic resonance elastography is not affected by hepatic steatosis
    Jie Chen
    Alina M. Allen
    Terry M. Therneau
    Jun Chen
    Jiahui Li
    Safa Hoodeshenas
    Jingbiao Chen
    Xin Lu
    Zheng Zhu
    Sudhakar K. Venkatesh
    Bin Song
    Richard L. Ehman
    Meng Yin
    European Radiology, 2022, 32 : 950 - 958
  • [39] Feasibility and significance of in vivo spleen stiffness measurement by magnetic resonance elastography
    Talwalkar, Jayant A.
    Yin, Meng
    Grimm, Roger
    Rossman, Phillip
    Romano, Anthony
    Kamath, Patrick S.
    Ehman, Richard
    GASTROENTEROLOGY, 2007, 132 (04) : A744 - A745
  • [40] Stiffness change of the supraspinatus muscle can be detected by magnetic resonance elastography
    Koga, Akihisa
    Itoigawa, Yoshiaki
    Suga, Mikio
    Morikawa, Daichi
    Uehara, Hirohisa
    Maruyama, Yuichiro
    Kaneko, Kazuo
    MAGNETIC RESONANCE IMAGING, 2021, 80 : 9 - 13