The Impact of Functionally Graded Material Insulator in a Three Phase Gas Insulated Busduct under Protrusion Defect

被引:0
|
作者
Subrahmanyam, Katta, V [1 ]
Rosalina, Mercy [2 ]
机构
[1] DA Govt Polytech Ongole, Govt Polytech Ongole D, Ongole, Andhra Pradesh, India
[2] Vignans Fdn Sci Technol & Res VFSTR, Vadlamudi, AP, India
关键词
FGM; Electric Field Stress; Insulator; Triple Junction; Metal Inser; Gas insulated busduct;
D O I
10.14447/jnmes.v27i1.a03
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Regardless of the environment, the power system network must be continuously operational. Current spacer failures of Gas Insulated Busduct (GIB) have been noted as a result of a number of manufacturing and switching faults, including delamination, protrusion, depression, gap, etc. These defects have a severe negative effect on the insulator's surface, which de -energises the gas -insulated busduct device and causes a significant financial loss. For the purpose of studying the electric stress at the Triple Junction, a Functionally Graded Material (FGM) spacer is built for a three phase GIB with protrusion irregularity in this work. The stress is reduced by inserting metal inserts at the end of the zero potential. Functionally graded materials are spatially distributed with numerous filler materials to achieve homogeneous electric field stress by doping them with various permittivity values. The spacer used in the simulation is made to withstand a range of voltages as well as varied FGM gradings. Grading's impact on electric field stress is identified and further diminished with the addition of the MI to the FGM insulator. The outcomes are discussed and analysed to demonstrate how well the proposed spacer works.
引用
收藏
页码:16 / 24
页数:9
相关论文
共 50 条
  • [41] Three-dimensional transient analysis of functionally graded material annular sector plate under various boundary conditions
    Liang, Xu
    Kou, Hai-lei
    Wang, Lizhong
    Palmer, Andrew C.
    Wang, Zhenyu
    Liu, Guohua
    COMPOSITE STRUCTURES, 2015, 132 : 584 - 596
  • [42] Thermoelastic interaction in a viscoelastic functionally graded half-space under three-phase-lag model
    Sur, Abhik
    Kanoria, M.
    EUROPEAN JOURNAL OF COMPUTATIONAL MECHANICS, 2014, 23 (5-6): : 179 - 198
  • [43] Research on the dynamic buckling of functionally graded material plates under conditions of one edge fixed and three edges simply supported
    Xin, Wang
    Jun, Han Zhi
    Li, Wu Ya
    2018 4TH INTERNATIONAL CONFERENCE ON ENERGY MATERIALS AND ENVIRONMENT ENGINEERING (ICEMEE 2018), 2018, 38
  • [44] Dynamic Analysis of Functionally Graded Fiber Reinforced Cylinders under an Impact Load by a Three Dimensional Mesh Free Approach
    Alihemmati J.
    Foroutan M.
    Soltanimaleki A.
    Journal of Dynamic Behavior of Materials, 2017, 3 (3) : 391 - 406
  • [45] Generalized thermoelastic functionally graded orthotropic hollow sphere under thermal shock with three-phase-lag effect
    Kar, Avijit
    Kanoria, M.
    EUROPEAN JOURNAL OF MECHANICS A-SOLIDS, 2009, 28 (04) : 757 - 767
  • [46] Three dimensional Free Vibration and Transient Analysis of Two Directional Functionally Graded Thick Cylindrical Panels Under Impact Loading
    Zafarmand, Hassan
    Salehi, Manouchehr
    Asemi, Kamran
    LATIN AMERICAN JOURNAL OF SOLIDS AND STRUCTURES, 2015, 12 (02): : 205 - 225
  • [47] The dynamic stress intensity factor around the anti-plane crack in an infinite strip functionally graded material under impact loading
    Zhao, Wenbin
    Hu, Zhixin
    Zhang, Xuexia
    Xie, Hailing
    Yu, Lujuan
    THEORETICAL AND APPLIED FRACTURE MECHANICS, 2014, 74 : 1 - 6
  • [48] Dynamic response of a crack in a functionally graded material between two dissimilar half planes under anti-plane shear impact load
    Babaei, R
    Lukasiewicz, SA
    ENGINEERING FRACTURE MECHANICS, 1998, 60 (04) : 479 - 487
  • [49] Thermoelastic Interaction in a Functionally Graded Medium Due to Refined Three-Phase-Lag Green-Naghdi Model under Gravitational Field
    Purkait, Pallabi
    Kanoria, Mridula
    JOURNAL OF MULTISCALE MODELLING, 2023, 14 (04)
  • [50] Three-phase enclosed Gas Insulated Substation technology up to 245 kV and its impact for improved Power System reliability
    Fuechsle, D.
    Kutlev, K., Sr.
    Dhara, R.
    Schulz, Th.
    2014 IEEE PES T&D CONFERENCE AND EXPOSITION, 2014,