Four-dimensional digital subtraction angiography to assess cerebral arteriovenous malformations

被引:2
|
作者
Xiang, Weichu [1 ]
Yan, Linhai [2 ]
Zhao, Yueyuan [1 ]
Yang, Ming [1 ]
Bai, Sanli [1 ]
Ma, Lianting [1 ]
Pan, Li [1 ]
机构
[1] Gen Hosp Cent Theater Command, Dept Neurosurg, 627 Wuluo Rd, Wuhan 430074, Peoples R China
[2] Guangzhou Med Univ, Dept Neurosurg, Affiliated Hosp 2, Guangzhou, Peoples R China
关键词
4D DSA; 4D DSA prototype; agreement analysis; cerebral arteriovenous malformation; 3D ROTATIONAL ANGIOGRAPHY; 4D DSA; DISPLAY; 2D;
D O I
10.1111/jon.13065
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose The performance of a novel prototype four-dimensional (4D) digital subtraction angiography (DSA) for cerebral arteriovenous malformation (AVM) diagnosis was evaluated and compared with that of two-dimensional (2D) and three-dimensional (3D) DSA. Methods In this retrospective study, 37 consecutive cerebral AVM patients were included. The standard diagnostic results were concluded from the 2D and 3D DSA. Two 4D DSA volumes were reconstructed for each patient by a commercial and a prototype software, then evaluated by two independent experienced neurosurgeons, who were blinded to the diagnosis and treatment process. The evaluation results were compared with the diagnostic results on Spetzler-Martin (SM) Grading Scale, number of feeding arteries, number of draining veins, and intranidal aneurysms. Results Complete agreement was achieved between 4D DSA and 2D and 3D DSA in SM Grading Scale and intracranial aneurysm identification (agreement coefficient: 1) for both reviewers. The agreement coefficients were .888 and .917 for both reviewers in feeding artery number determination using 4D DSA product and 4D DSA prototype, respectively. The agreement coefficients in draining vein number determination were all larger than .94 for both reviewers using both 4D DSA volumes. Conclusions The performance of this prototype 4D DSA in cerebral AVMs diagnosis was largely equivalent to that of 2D and 3D DSA combination. Four-dimensional DSA can be regarded as a very good complement for 2D DSA in cerebral AVM diagnosis.
引用
收藏
页码:67 / 72
页数:6
相关论文
共 50 条
  • [21] A Prospective Study Comparing the Three-Dimensional Rotational Angiography and Two-Dimensional Digital Subtraction Angiography in Evaluation of Brain Arteriovenous Malformations
    Pan, Somnath
    Kannath, Santhosh K.
    Singh, Gurpreet
    Rajan, Jayadevan E.
    NEUROLOGY INDIA, 2022, 70 (05) : 1905 - +
  • [22] Is four-dimensional CT angiography as effective as digital subtraction angiography in the detection of the underlying causes of intracerebral haemorrhage: a systematic review
    C. E. Denby
    K. Chatterjee
    R. Pullicino
    S. Lane
    M. R. Radon
    K. V. Das
    Neuroradiology, 2020, 62 : 273 - 281
  • [23] Estimation of the number of feeding arteries of spinal arteriovenous malformations by using three-dimensional digital subtraction angiography
    Takamiya, Soichiro
    Osanai, Toshiya
    Seki, Toshitaka
    Fujima, Noriyuki
    Hida, Kazutoshi
    Asano, Takeshi
    Yamazaki, Kazuyoshi
    Hamauchi, Shuji
    Sasamori, Toru
    Ono, Kota
    Terasaka, Shunsuke
    Houkin, Kiyohiro
    EUROPEAN SPINE JOURNAL, 2019, 28 (04) : 842 - 848
  • [24] Is four-dimensional CT angiography as effective as digital subtraction angiography in the detection of the underlying causes of intracerebral haemorrhage: a systematic review
    Denby, C. E.
    Chatterjee, K.
    Pullicino, R.
    Lane, S.
    Radon, M. R.
    Das, K., V
    NEURORADIOLOGY, 2020, 62 (03) : 273 - 281
  • [25] Estimation of the number of feeding arteries of spinal arteriovenous malformations by using three-dimensional digital subtraction angiography
    Soichiro Takamiya
    Toshiya Osanai
    Toshitaka Seki
    Noriyuki Fujima
    Kazutoshi Hida
    Takeshi Asano
    Kazuyoshi Yamazaki
    Shuji Hamauchi
    Toru Sasamori
    Kota Ono
    Shunsuke Terasaka
    Kiyohiro Houkin
    European Spine Journal, 2019, 28 : 842 - 848
  • [26] Noncontrast-Enhanced Four-Dimensional MR Angiography for the Evaluation of Cerebral Arteriovenous Malformation: A Preliminary Trial
    Xu, Junling
    Shi, Dapeng
    Chen, Chuanliang
    Li, Yongli
    Wang, Meiyun
    Han, Xinwei
    Jin, Lixin
    Bi, Xiaoming
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (05) : 1199 - 1205
  • [27] Haemodynamic evaluation of cerebral arteriovenous malformations by quantification of transit time using high speed digital subtraction angiography: basic considerations
    Matsumoto, K
    Urano, M
    Hirai, M
    Masaki, H
    Tenjin, H
    Mineura, K
    JOURNAL OF CLINICAL NEUROSCIENCE, 2000, 7 : 39 - 41
  • [28] Virtual 2D angiography from four-dimensional digital subtraction angiography (4D-DSA): A feasibility study
    Yu, Jay F.
    Pung, Leland
    Minami, Hataka
    Mueller, Kerstin
    Khangura, Rajkamal
    Darflinger, Robert
    Hetts, Steven W.
    Cooke, Daniel L.
    INTERVENTIONAL NEURORADIOLOGY, 2021, 27 (02) : 307 - 313
  • [29] DIGITAL SUBTRACTION ANGIOGRAPHY AND INFRATENTORIAL ARTERIOVENOUS MALFORMATION
    LATCHAW, JP
    ACTA NEUROCHIRURGICA, 1985, 78 (1-2) : 65 - 65
  • [30] Machine Learning Application With Quantitative Digital Subtraction Angiography for Detection of Hemorrhagic Brain Arteriovenous Malformations
    Hong, Jia-Sheng
    Lin, Chung-Jung
    Lin, Yue-Hsin
    Lee, Cheng-Chia
    Yang, Huai-Che
    Meng, Ling-Hsuan
    Lin, Te-Ming
    Hu, Yong-Sin
    Guo, Wan-Yuo
    Chu, Wei-Fa
    Wu, Yu-Te
    IEEE ACCESS, 2020, 8 : 204573 - 204584