Technical feasibility and safety of the alternative snare technique using a 0.018-inch guide wire and 5-French catheter for double-J ureteral stent removal

被引:0
|
作者
Lim, Ye Won [1 ]
Oh, Chang Hoon [1 ,4 ]
Lee, Hyo Jeong [1 ]
Cho, Soo Buem [2 ]
Kim, Myung Soo [3 ]
机构
[1] Ewha Womans Univ, Mokdong Hosp, Coll Med, Dept Radiol, Seoul, South Korea
[2] Ewha Womans Univ, Seoul Hosp, Coll Med, Dept Radiol, Seoul, South Korea
[3] Ewha Womans Univ, Mokdong Hosp, Coll Med, Dept Urol, Seoul, South Korea
[4] Ewha Womans Univ, Coll Med, Dept Radiol, 260 Gonghang daero, Seoul 07804, South Korea
关键词
percutaneous removal; snare technique; ureteral stent; RETRIEVAL; MANAGEMENT;
D O I
10.1097/MD.0000000000037525
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To evaluate the technical feasibility of the alternative snare technique using a 0.018-inch guide wire and 5-French (Fr) catheter for double-J ureteral stent (DJUS) removal. In this retrospective study, 11 DJUS were removed in 9 consecutive patients between July 2023 and October 2023. We evaluated patient characteristics, DJUS characteristics, and procedure characteristics. Out of 11 cases, 8 (72.7%) were successful in removing the DJUS using the alternative snare technique without major complications. The average time between DJUS insertion and removal was 47.4 +/- 50.0 days. The most common DJUS size was an 8-Fr, with proximal tips predominantly in the proximal ureter and renal pelvis. The mean procedure time for successful cases was 15.2 +/- 16.8 minutes. Three failed cases, attributed to obstructions like debris, were later successfully addressed using the ALN inferior vena cava filter removal kit, forceps, and modified snare technique. The alternative snare technique using a 0.018-inch guidewire and Fr catheter is safe and effective in cases of DJUS removal.
引用
收藏
页数:6
相关论文
共 5 条
  • [1] THE MISPLACED DOUBLE-J URETERAL STENT - TECHNIQUE FOR REPOSITIONING USING THE NITINOL GOOSENECK SNARE
    PATEL, U
    KELLETT, MJ
    CLINICAL RADIOLOGY, 1994, 49 (05) : 333 - 336
  • [2] Feasibility and safety of magnetic-end double-J ureteral stent insertion and removal in children
    Marc Chalhoub
    Jules Kohaut
    Nicolas Vinit
    Nathalie Botto
    Yves Aigrain
    Yves Héloury
    Henri Lottmann
    Thomas Blanc
    World Journal of Urology, 2021, 39 : 1649 - 1655
  • [3] The safety and efficacy of through-and-through wire technique for ureteral Double-J stent placement
    Chen, Cheng Shi
    Zeng, Chu Hui
    Shin, Ji Hoon
    Park, Suyoung
    Li, Hai Liang
    Li, Fang Kun
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2024, 40 (09) : 1907 - 1913
  • [4] Feasibility and safety of magnetic-end double-J ureteral stent insertion and removal in children
    Chalhoub, Marc
    Kohaut, Jules
    Vinit, Nicolas
    Botto, Nathalie
    Aigrain, Yves
    Heloury, Yves
    Lottmann, Henri
    Blanc, Thomas
    WORLD JOURNAL OF UROLOGY, 2021, 39 (05) : 1649 - 1655
  • [5] An Alternative Loop Snare Technique with Many Loops Using a Simple Guide-Wire for Removal of a Double J Stent: A Case Series
    Kim, Su Ho
    Choi, Byung Gil
    Suk, Oh Jung
    Chun, Ho Jong
    Lee, Hae Giu
    IRANIAN JOURNAL OF RADIOLOGY, 2020, 17 (03) : 1 - 4