Validation of an automated artificial intelligence system for 12-lead ECG interpretation

被引:3
|
作者
Herman, Robert [1 ,2 ,3 ,8 ]
Demolder, Anthony [3 ]
Vavrik, Boris [3 ]
Martonak, Michal [3 ]
Boza, Vladimir [3 ,4 ]
Kresnakova, Viera [3 ,5 ]
Iring, Andrej [3 ]
Palus, Timotej [3 ]
Bahyl, Jakub [3 ]
Nelis, Olivier [2 ]
Beles, Monika [2 ]
Fabbricatore, Davide [2 ]
Perl, Leor [6 ]
Bartunek, Jozef [2 ]
Hatala, Robert [7 ,9 ]
机构
[1] Univ Naples Federico II, Dept Adv Biomed Sci, Naples, Italy
[2] Cardiovasc Ctr Aalst, Aalst, Belgium
[3] Powerful Med, Bratislava, Slovakia
[4] Comenius Univ, Fac Math Phys & Informat, Bratislava, Slovakia
[5] Tech Univ Kosice, Dept Cybernet & Artificial Intelligence, Kosice, Slovakia
[6] Rabin Med Ctr, Dept Cardiol, Petah Tiqwa, Israel
[7] Natl Inst Cardiovasc Dis, Dept Arrhythmia & Pacing, Bratislava, Slovakia
[8] Univ Naples Federico II, Dept Biomed Sci, Cso Umberto I 40, I-80138 Naples, Italy
[9] Natl Inst Cardiovasc Dis, Dept Arrhythmia & Pacing, Pod Krsnouhorkou 1, Bratislava 83384, Slovakia
关键词
Artificial intelligence; Computerized electrocardiogram; Rhythm analysis; Acute coronary syndrome; Conduction abnormality; Machine learning; ELECTROCARDIOGRAM INTERPRETATION; COMPUTER; ERRORS;
D O I
10.1016/j.jelectrocard.2023.12.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The electrocardiogram (ECG) is one of the most accessible and comprehensive diagnostic tools used to assess cardiac patients at the first point of contact. Despite advances in computerized interpretation of the electrocardiogram (CIE), its accuracy remains inferior to physicians. This study evaluated the diagnostic performance of an artificial intelligence (AI)-powered ECG system and compared its performance to current state-of -the-art CIE.Methods: An AI-powered system consisting of 6 deep neural networks (DNN) was trained on standard 12-lead ECGs to detect 20 essential diagnostic patterns (grouped into 6 categories: rhythm, acute coronary syndrome (ACS), conduction abnormalities, ectopy, chamber enlargement and axis). An independent test set of ECGs with diagnostic consensus of two expert cardiologists was used as a reference standard. AI system performance was compared to current state-of-the-art CIE. The key metrics used to compare performances were sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and F1 score.Results: A total of 932,711 standard 12-lead ECGs from 173,949 patients were used for AI system development. The independent test set pooled 11,932 annotated ECG labels. In all 6 diagnostic categories, the DNNs achieved high F1 scores: Rhythm 0.957, ACS 0.925, Conduction abnormalities 0.893, Ectopy 0.966, Chamber enlargement 0.972, and Axis 0.897. The diagnostic performance of DNNs surpassed state-of-the-art CIE for the 13 out of 20 essential diagnostic patterns and was non-inferior for the remaining individual diagnoses.Conclusions: Our results demonstrate the AI-powered ECG model's ability to accurately identify electrocardiographic abnormalities from the 12-lead ECG, highlighting its potential as a clinical tool for healthcare professionals.
引用
下载
收藏
页码:147 / 154
页数:8
相关论文
共 50 条
  • [21] A novel mobile transtelephonic system with synthesized 12-lead ECG
    Hadzievski, L
    Bojovic, B
    Vukcevic, V
    Belicev, P
    Pavlovic, S
    Vasiljevic-Pokrajcic, Z
    Ostojic, M
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2004, 8 (04): : 428 - 438
  • [22] Artificial Intelligence-Enhanced Smartwatch ECG for Heart Failure-Reduced Ejection Fraction Detection by Generating 12-Lead ECG
    Kwon, Joon-myoung
    Jo, Yong-Yeon
    Lee, Soo Youn
    Kang, Seonmi
    Lim, Seon-Yu
    Lee, Min Sung
    Kim, Kyung-Hee
    DIAGNOSTICS, 2022, 12 (03)
  • [23] COMPARISON OF DIGITAL 12-LEAD ECG AND DIGITAL 12-LEAD HOLTER ECG RECORDINGS IN HEALTHY MALE SUBJECTS
    Taubel, J.
    Naseem, A.
    Shakeri-Nejad, K.
    Dingemanse, J.
    Ferber, G.
    Camm, A. J.
    CLINICAL PHARMACOLOGY & THERAPEUTICS, 2011, 89 : S11 - S11
  • [24] A new 5 electrode 12-lead ECG (EASI) is equivalent to standard 12-lead ECG for myocardial infarction
    Wehr, G
    Peters, R
    Khalifé, K
    Banning, A
    Kuehlkamp, V
    Rickards, A
    Duller, B
    Sechtem, U
    INTENSIVE CARE MEDICINE, 2002, 28 : S78 - S78
  • [25] Design and technical validation to generate a synthetic 12-lead electrocardiogram dataset to promote artificial intelligence research
    Yoo, Hakje
    Moon, Jose
    Kim, Jong-Ho
    Joo, Hyung Joon
    HEALTH INFORMATION SCIENCE AND SYSTEMS, 2023, 11 (01)
  • [26] Detection and removal of pacing artifacts prior to automated analysis of 12-lead ECG
    Haq, Kazi T.
    Javadekar, Neeraj
    Tereshchenko, Larisa G.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 133
  • [27] Automated detection of ventricular pre-excitation in pediatric 12-lead ECG
    Gregg, Richard E.
    Zhou, Sophia H.
    Dubin, Anne M.
    JOURNAL OF ELECTROCARDIOLOGY, 2016, 49 (01) : 37 - 41
  • [28] Methodology for Automated Detection of Fragmentation in QRS complex of Standard 12-lead ECG
    Maheshwari, Sidharth
    Acharyya, Amit
    Puddu, Paolo Emilio
    Schiariti, Michele
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 3789 - 3792
  • [29] CLINICAL VALIDATION OF A NOVEL, SMARTPHONE-BASED 12-LEAD ECG DEVICE
    Stavrakis, Stavros
    Whyte, Seabrook
    Sample, Karlie
    Barber, Rylee
    Albert, David
    Po, Sunny S.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 2034 - 2034
  • [30] Acute myocardial infarction detected in the 12-lead ECG by artificial neural networks
    Heden, B
    Ohlin, H
    Rittner, R
    Edenbrandt, L
    CIRCULATION, 1997, 96 (06) : 1798 - 1802