Influence of Home Location on Follow-Up Compliance after Endovascular Treatment for Abdominal Aortic Aneurysm

被引:1
|
作者
Salvi, Charlene [1 ,4 ]
Besancenot, Aurelien [2 ]
Sebahi, Soumia [1 ]
Rinckenbach, Simon [1 ,3 ]
Du Mont, Lucie Salomon [1 ,3 ]
机构
[1] Univ Hosp, Vasc Surg Unit, Besancon, France
[2] Hop Nord Franche Comte, Vasc Surg, Trevenans, France
[3] Univ Franche Comte, Besancon, France
[4] Hop Univ Jean Minjoz, Serv Chirurg Vasc, 3 Blvd Fleming, F-25030 Besancon, France
关键词
POSTOPERATIVE SURVEILLANCE; REPAIR; RUPTURE;
D O I
10.1016/j.avsg.2022.10.028
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The complications of EVAR require compliance to a close follow-up imaging. The purpose of this study was to determine whether home location predicted a poor compliance to imaging follow-up after EVAR. Methods: We analyzed a cohort of patients treated by EVAR at the Besancon University Hospital between 2007 and 2017. Follow-up imaging followed the French High Health Authority recommendations. Noncompliance with follow-up compliance was defined as a first missed postoperative appointment or 2 consecutive missed appointments after the first control CT-scan, and 2 groups of patients were identified: compliant (group C) or noncompliant (group NC). Univariate and multivariate analyzes were used to investigate compliance risk factors. Collected complications included endoleaks, limb thrombosis, infections, and secondary ruptures. Results: Two hundred and fifty-eight of the 359 patients treated during this period were enrolled, including 233 men (90.3%), with a mean age of 74.0 years (+/- 9.0) and a mean follow-up of 5.0 years (+/- 2.6). The compliance rate was 38.8% and the 1-year mortality rate was 12.0%. Using univariate and multivariate analysis, a place of residence greater located over 60 min away from the hospital had a poor effect on compliance (Odd ratio [OR] = 0.58; P = 0.047). Peripheral arterial occlusive disease (PAD) and an abdominal aortic aneurysm (AAA) diameter greater than 5.0 cm were protective factors (OR = 2.23; P = 0.006 and OR = 1.85, respectively; P = 0.002). Four-year all-cause mortality was 21.0% in group C and 17.0% in the NC group (P = 0.54). Complications were more significant in group C (59.0%) compared to group NC (39.0%) (P = 0.001). Two ruptures occurred in the NC group (1.3%), versus none in the C group (P = 0.25). Conclusions: In this study, a long distance from the home to the hospital was a detrimental factor for follow up compliance. However, a good compliance did not decrease the 4-year mortality rate. The high rate of noncompliance found should lead to a more personalized follow-up strategy taking into account the anatomical elements but also the comorbidities and some social aspects.
引用
收藏
页码:48 / 55
页数:8
相关论文
共 50 条
  • [21] Endovascular treatment of abdominal aortic aneurysm: preoperative investigations, implantation technique, postoperative follow-up, and results
    Lachat, M
    Pfammatter, T
    Schneider, D
    Schmidli, J
    Hilfiker, P
    Koppensteiner, R
    Vogt, PR
    Turina, M
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1999, 129 (04) : 113 - 119
  • [22] A Dedicated Surveillance Program Improves Compliance with Endovascular Aortic Aneurysm Repair Follow-up
    Cohen, Jade
    Pai, Akila
    Sullivan, Timothy M.
    Alden, Peter
    Alexander, Jason Q.
    Cragg, Andrew
    Manunga, Jesse M.
    Stephenson, Elliot J.
    Skeik, Nedaa
    Titus, Jessica M.
    ANNALS OF VASCULAR SURGERY, 2017, 44 : 59 - 66
  • [23] Endovascular abdominal aortic aneurysm repair: 5-year follow-up results
    Sandford, R. M.
    Bown, M. J.
    Sayers, R. D.
    Fishwick, G.
    London, N. J.
    Nasim, A.
    ANNALS OF VASCULAR SURGERY, 2008, 22 (03) : 372 - 378
  • [24] Endovascular therapy of abdominal aortic aneurysm:: Results of a mid-term follow-up
    Pitton, MB
    Schweitzer, H
    Herber, S
    Schmiedt, W
    Neufang, A
    Düber, C
    Thelen, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (10): : 1392 - 1402
  • [25] Inflammatory Abdominal Aortic Aneurysm Endovascular Repair into the Long-Term Follow-Up
    Coppi, Gioacchino
    Rametta, Francesco
    Aiello, Stefano
    Saitta, Giuseppe
    Gennai, Stefano
    Silingardi, Roberto
    ANNALS OF VASCULAR SURGERY, 2010, 24 (08) : 1053 - 1059
  • [26] Follow-up Compliance in Patients Undergoing Abdominal Aortic Aneurysm Repair at VA Hospitals
    Abuhakmeh, Yousef
    Shahbazian, Sona
    Ashouri, Yazan
    Hsu, Chiu-Hsieh
    Devito, Peter
    Zhou, Wei
    JOURNAL OF VASCULAR SURGERY, 2023, 77 (06) : E103 - E103
  • [27] Abdominal aortic aneurysm follow-up by shear wave elasticity imaging after endovascular repair in a canine model
    Bertrand-Grenier, Antony
    Lerouge, Sophie
    Tang, An
    Salloum, Eli
    Therasse, Eric
    Kauffmann, Claude
    Heon, Helene
    Salazkin, Igor
    Cloutier, Guy
    Soulez, Gilles
    EUROPEAN RADIOLOGY, 2017, 27 (05) : 2161 - 2169
  • [28] Clinical Utility and Safety of Noncontrast Computed Tomography for Follow-up After Endovascular Abdominal Aortic Aneurysm Repair
    Bobadilla, Joseph L.
    Suwanabol, Pasithorn
    Reeder, Scott
    Pozniak, Myron
    Tefera, Girma
    JOURNAL OF VASCULAR SURGERY, 2010, 51 : 28S - 29S
  • [29] Abdominal aortic aneurysm follow-up by shear wave elasticity imaging after endovascular repair in a canine model
    Antony Bertrand-Grenier
    Sophie Lerouge
    An Tang
    Eli Salloum
    Eric Therasse
    Claude Kauffmann
    Hélène Héon
    Igor Salazkin
    Guy Cloutier
    Gilles Soulez
    European Radiology, 2017, 27 : 2161 - 2169
  • [30] Loss to Follow-Up After Endovascular Abdominal Aortic Aneurysm Repair, a Suburban Community Teaching Practice Experience
    Juma, Einstein
    Dowling, Caitlyn
    Ha, Minje
    Mann, David
    Kim, Minha
    DiLello, Lauren
    Schlieder, Ian
    Dietzek, Alan
    JOURNAL OF VASCULAR SURGERY, 2019, 69 (06) : E85 - E85