Urine transfer devices may impact urinary particle results: a pre-analytical study

被引:2
|
作者
Debunne, Nathan [2 ]
Delanghe, Joris [3 ]
Raman, Leen [2 ]
Oyaert, Matthijs [1 ]
机构
[1] Ghent Univ Hosp, Dept Lab Med, C Heymanslaan 10, B-9000 Ghent, Belgium
[2] Ghent Univ Hosp, Dept Lab Med, Ghent, Belgium
[3] Ghent Univ Hosp, Dept Diagnost Sci, Ghent, Belgium
关键词
pre-analytical phase; stability; urinalysis; urine particle analysis; urine test strip analysis; SEDIMENT; DIAGNOSIS; PROTEIN;
D O I
10.1515/cclm-2023-0327
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Well-standardized procedures in the pre-analytical phase of urine diagnostics is of utmost importance to obtain reliable results. We investigated the effect of different urine collection methods and the associated urine transfer tubes on urine test strip and particle results. Methods: In total, 146 selected urine samples were subdivided into three different collection containers and subsequently transferred into its accompanying transfer tube ( BD, Greiner, Sarstedt vacuum and Sarstedt aspiration). As reference, the original urine sample was directly measured on the analyser. Both chemical test strip analysis (Sysmex UC-3500) and fluorescence flow cytometry particle analysis (Sysmex UF-5000) were performed on all samples. Results: No statistically significant differences in test strip results were found between the studied transfer methods. On the contrary, transfer of urine samples to the secondary tubes affected their particle counts. Clinically significant reductions in counts of renal tubular epithelial cells and hyaline casts were observed using the BD and Greiner transfer tubes and in counts of pathological casts using the BD, Greiner and Sarstedt vacuum tubes. Conclusions: The results of this study indicate that the use of urine transfer tubes may impact counts of fragile urine particles. Clinical laboratories need to be aware about the variation that urine collection methods can induce on urine particle counts.
引用
收藏
页码:2186 / 2194
页数:9
相关论文
共 50 条
  • [21] The key points in the pre-analytical procedures of blood and urine samples in metabolomics studies
    Bi, Hai
    Guo, Zhengyang
    Jia, Xiao
    Liu, Huiying
    Ma, Lulin
    Xue, Lixiang
    METABOLOMICS, 2020, 16 (06)
  • [22] Validation of the effect of pre-analytical treatment of urine before quantitative proteomic analysis
    Court, M.
    Brun, V
    Bruley, C.
    Allory, Y.
    Garin, J.
    Masselon, C.
    BULLETIN DU CANCER, 2008, 95 : S14 - S14
  • [23] Pre-analytical contamination of pediatric urine drug screening samples with tributoxyethylphosphate (TBEP)
    Paul, Heather
    Sadrzadeh, S. M. Hossein
    Boyd, Jessica
    CLINICAL BIOCHEMISTRY, 2019, 74 : 93 - 93
  • [24] The key points in the pre-analytical procedures of blood and urine samples in metabolomics studies
    Hai Bi
    Zhengyang Guo
    Xiao Jia
    Huiying Liu
    Lulin Ma
    Lixiang Xue
    Metabolomics, 2020, 16
  • [25] The Impact of Pre-analytical Quality Initiatives on Cholangiocarcinoma Diagnostics in Thailand
    Koonmee, Supinda
    Sangkhamanon, Sakkarn
    Intarawichian, Piyapharom
    Aphivatanasiri, Chaiwat
    Kunprom, Waritta
    Sa-ngiamwibool, Prakasit
    Balthaisong, Suwit
    Phuyao, Chitsakul
    Prajumwongs, Piya
    Alaghehbandan, Reza
    Thanee, Malinee
    FRONTIERS IN PUBLIC HEALTH, 2022, 10
  • [26] Impact of pre-analytical variables on deep learning accuracy in histopathology
    Jones, Andrew D.
    Graff, John Paul
    Darrow, Morgan
    Borowsky, Alexander
    Olson, Kristin A.
    Gandour-Edwards, Regina
    Mitra, Ananya Datta
    Wei, Dongguang
    Gao, Guofeng
    Durbin-Johnson, Blythe
    Rashidi, Hooman H.
    HISTOPATHOLOGY, 2019, 75 (01) : 39 - 53
  • [27] Study of Pre-analytical effects on Breast Cancer Biomarkers
    Molina, Mariel
    Jain, Pragya Virendrakumar
    Cortina, Chandler
    Schneider, Ellen
    Sun, Yunguang
    Rui, Hallgeir
    Jorns, Julie
    LABORATORY INVESTIGATION, 2023, 103 (03) : S181 - S182
  • [28] A study of pre-analytical variables in clinical biochemistry laboratory
    Ashakiran, S.
    Sumati, M. E.
    Murthy, N. Krishna
    CLINICAL BIOCHEMISTRY, 2011, 44 (10-11) : 944 - 945
  • [29] IMPACT OF PRE-ANALYTICAL HANDLING CONDITIONS ON THE EXPRESSION OF URINARY EXTRACELLULAR VESICLE PROTEIN BIOMARKER FOR BLADDER CANCER DIAGNOSIS
    Park, Jinsung
    Lee, Jisu
    Kim, Eunha
    Park, Joohee
    Lee, Myung-Shin
    JOURNAL OF UROLOGY, 2024, 211 (05): : E229 - E230
  • [30] Optimization of analytical and pre-analytical conditions for MALDI-TOF-MS human urine protein profiles
    Calvano, C. D.
    Aresta, A.
    Iacovone, M.
    De Benedetto, G. E.
    Zambonin, C. G.
    Battaglia, M.
    Ditonno, P.
    Rutigliano, M.
    Bettocchi, C.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 51 (04) : 907 - 914