Determining Intraosseous Needle Placement Using Point-of-Care Ultrasound in a Swine (Sus scrofa) Model

被引:0
|
作者
Kyle, Adrianna, I [1 ]
Auten, Jonathan D. [1 ]
Zarow, Gregory J.
Natarajan, Ramesh [1 ]
Bianchi, William D. [1 ]
Speicher, Matthew, V [1 ]
Palma, James [1 ]
Gaspary, Micah J. [1 ]
机构
[1] Naval Med Ctr Portsmouth, Clin Invest Dept, Combat Trauma Res Grp, Portsmouth, VA 23708 USA
关键词
VASCULAR ACCESS; CONFIRMATION; PRESSURE; INFUSION; DEVICES; TRAUMA;
D O I
10.1093/milmed/usac108
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective Intraosseous (IO) access is critical in resuscitation, providing rapid access when peripheral vascular attempts fail. Unfortunately, misplacement commonly occurs, leading to possible fluid extravasation and tissue necrosis. Current research exploring the utility of bedside ultrasound in confirming IO line placement is limited by small sample sizes of skeletally immature subjects or geriatric cadaveric models. The objective of this study was to investigate the potential value of ultrasound confirming IO needle placement in a live tissue model with bone densities approximated to the young adult medical or trauma patient. Materials and Methods In this randomized, blinded prospective study, IO devices were placed into the bilateral humeri of 36 sedated adult swine (N = 72) with bone densities approximating that of a 20-39-year-old adult. Of the 72 lines, 53 were randomized to the IO space ("correct") and 19 into the subcutaneous tissue ("incorrect"). Four emergency physicians with variable ultrasound experience and blinded to needle location independently assessed correct or incorrect needle placements based on the presence of an intramedullary "flare" on color power Doppler (CPD) during a saline flush. Participants adjusted the ultrasound beam trajectory and recorded assessments up to three times, totaling 204 separate observations. Results Overall, sensitivity for placement confirmation was 72% (95% CI: 64%-79%). Specificity was 79% (95% CI: 66%-89%). First assessment and final assessment results were similar. More experienced sonographers demonstrated greater success in identifying inaccurate placements with a specificity of 86% (95% CI: 63%-96%). Conclusion Within the context of this study, point-of-care ultrasound with CPD did not reliably confirm IO line placement. However, more accurate assessments of functional and malpositioned catheters were noted in sonographers with greater than 4 years of experience. Future study into experienced sonographers' use of CPD to confirm IO catheter placement is needed.
引用
收藏
页码:2969 / 2974
页数:6
相关论文
共 50 条
  • [21] Point-of-Care Ultrasound to Locate Retained Intravenous Drug Needle in the Femoral Artery
    Primi, Blake
    Thiessen, Molly E. W.
    WESTERN JOURNAL OF EMERGENCY MEDICINE, 2016, 17 (06) : 817 - 818
  • [22] COMMENT ON: USING POINT-OF-CARE ULTRASOUND ON HOME VISITS
    Flores, Christopher V.
    Simon, Lauren M.
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2020, 68 (03) : 668 - 669
  • [23] REPLY TO: USING POINT-OF-CARE ULTRASOUND ON HOME VISITS
    Bonnel, Alexander R.
    Baston, Cameron M.
    Wallace, Paul
    Panebianco, Nova
    Kinosian, Bruce
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2020, 68 (03) : 669 - 669
  • [24] Point-of-Care Ultrasound for Confirmation of Nasogastric and Orogastric Tube Placement in Pediatric Patients
    Claiborne, Mary Kate
    Gross, Toni
    McGreevy, Jon
    Riemann, Monique
    Temkit, M'hamed
    Augenstein, Julie
    PEDIATRIC EMERGENCY CARE, 2021, 37 (12) : E1611 - E1615
  • [25] Point-of-Care Ultrasound Protocol for Insertion and Confirmation of Central Venous Catheter Placement
    Soares, Pedro R.
    Maia, Andre
    Fernandes, Jorge R.
    Faustino, Diogo
    Campos, Ana Luisa
    Almeida, Luis R.
    Mariz, Jose
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (09)
  • [26] A FINANCIAL MODEL FOR POINT-OF-CARE ULTRASOUND IN A PEDIATRIC INTENSIVE CARE UNIT
    Wiedemann, Nathan
    Horowitz, Russell
    Harris, Zena
    Ruppe, Michael
    Thai, Alexander
    Sutton, Brad
    Kim, In
    Foster, Ben
    CRITICAL CARE MEDICINE, 2016, 44 (12)
  • [27] A Comparison of Flow Rates and Hematologic Safety Between Intraosseous Blood Transfusion Strategies in a Swine (Sus scrofa) Model of Hemorrhagic Shock: A Pilot Study
    Krepela, A.
    Auten, J.
    Mclean, J.
    Fortner, G.
    Murnan, S.
    Kemp, J.
    Roszko, P.
    Fishback, J.
    ANNALS OF EMERGENCY MEDICINE, 2017, 70 (04) : S139 - S139
  • [28] Accuracy of point-of-care ultrasound for determining the adequacy of pediatric forearm fracture reductions
    Sik, Nihan
    Ozturk, Ali
    Kosay, Mustafa Can
    Yilmaz, Durgul
    Duman, Murat
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2021, 48 : 243 - 248
  • [29] Intraosseous Blood Correlates with Venous Blood in Healthy Subjects Using Point-of-Care Analyzers
    Montez, D. F.
    Puga, T. A.
    Garcia, M. R.
    Miller, L. J.
    Davlantes, C.
    Saussy, J. M.
    Philbeck, T. E., Jr.
    ANNALS OF EMERGENCY MEDICINE, 2013, 62 (04) : S40 - S40
  • [30] Intravenous and Intraosseous Blood Transfusion With Three Different Pediatric Pressure Transfusion Strategies in an Immature Swine (Sus scrofa) Model of Hemorrhagic Shock: A Pilot Study
    Bianchi, William
    George, Taylor
    McEvoy, Christian
    Piehl, Mark
    Manzano, Ana
    Boboc, Michael
    Zarow, Gregory J.
    Natarajan, Ramesh
    Gaspary, Micah J.
    Auten, Jonathan
    Roszko, Paul J. D.
    MILITARY MEDICINE, 2020, 185 : 121 - 129