Determining Intraosseous Needle Placement Using Point-of-Care Ultrasound in a Swine (Sus scrofa) Model

被引:0
|
作者
Kyle, Adrianna, I [1 ]
Auten, Jonathan D. [1 ]
Zarow, Gregory J.
Natarajan, Ramesh [1 ]
Bianchi, William D. [1 ]
Speicher, Matthew, V [1 ]
Palma, James [1 ]
Gaspary, Micah J. [1 ]
机构
[1] Naval Med Ctr Portsmouth, Clin Invest Dept, Combat Trauma Res Grp, Portsmouth, VA 23708 USA
关键词
VASCULAR ACCESS; CONFIRMATION; PRESSURE; INFUSION; DEVICES; TRAUMA;
D O I
10.1093/milmed/usac108
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective Intraosseous (IO) access is critical in resuscitation, providing rapid access when peripheral vascular attempts fail. Unfortunately, misplacement commonly occurs, leading to possible fluid extravasation and tissue necrosis. Current research exploring the utility of bedside ultrasound in confirming IO line placement is limited by small sample sizes of skeletally immature subjects or geriatric cadaveric models. The objective of this study was to investigate the potential value of ultrasound confirming IO needle placement in a live tissue model with bone densities approximated to the young adult medical or trauma patient. Materials and Methods In this randomized, blinded prospective study, IO devices were placed into the bilateral humeri of 36 sedated adult swine (N = 72) with bone densities approximating that of a 20-39-year-old adult. Of the 72 lines, 53 were randomized to the IO space ("correct") and 19 into the subcutaneous tissue ("incorrect"). Four emergency physicians with variable ultrasound experience and blinded to needle location independently assessed correct or incorrect needle placements based on the presence of an intramedullary "flare" on color power Doppler (CPD) during a saline flush. Participants adjusted the ultrasound beam trajectory and recorded assessments up to three times, totaling 204 separate observations. Results Overall, sensitivity for placement confirmation was 72% (95% CI: 64%-79%). Specificity was 79% (95% CI: 66%-89%). First assessment and final assessment results were similar. More experienced sonographers demonstrated greater success in identifying inaccurate placements with a specificity of 86% (95% CI: 63%-96%). Conclusion Within the context of this study, point-of-care ultrasound with CPD did not reliably confirm IO line placement. However, more accurate assessments of functional and malpositioned catheters were noted in sonographers with greater than 4 years of experience. Future study into experienced sonographers' use of CPD to confirm IO catheter placement is needed.
引用
收藏
页码:2969 / 2974
页数:6
相关论文
共 50 条
  • [1] Feasibility of point-of-care colour Doppler ultrasound confirmation of intraosseous needle placement during resuscitation
    Tsung, James W.
    Blaivas, Michael
    Stone, Michael B.
    RESUSCITATION, 2009, 80 (06) : 665 - 668
  • [2] Intraosseous Infusion of Crystalloid Fluid Immediately After Intraosseous Infusion of Nitroglycerin in the Proximal Tibia of a Swine (Sus Scrofa) Model
    Miller, J.
    Lairet, J.
    DeLorenzo, R.
    Pitotti, R.
    ANNALS OF EMERGENCY MEDICINE, 2009, 54 (03) : S140 - S140
  • [3] Using Point-of-Care Ultrasound to Assess Gastrostomy Balloon Placement
    Ravi, Nithin S.
    Mistry, Rakesh D.
    Orsborn, Jonathan
    Dillon, Mairead
    Tutman, Jeffrey
    Hayes, Kari
    Wallace, Carmelle
    Lowe, Jeremiah T.
    Vu, Tien
    JOURNAL OF EMERGENCY MEDICINE, 2025, 70 : 110 - 116
  • [4] The relationship between intraosseous catheter tip placement, flow rates, and infusion pressures in a high bone density cadaveric swine (Sus scrofa) model
    Gehrz, Joseph A.
    Kay, Victoria C.
    Grady, Derek W.
    Emerling, Alec D.
    Mcgowan, Andrew
    Reilly, Erin R.
    Bebarta, Vikhyat S.
    Nassiri, Joshua
    Vinals, Jorge
    Zarow, Gregory J.
    Auten, Jonathan D.
    JOURNAL OF THE AMERICAN COLLEGE OF EMERGENCY PHYSICIANS OPEN, 2024, 5 (04)
  • [5] Use of Intraosseous Hydroxocobalamin for Treatment of Hemorrhagic Shock in an Adult Swine (Sus Scrofa) Model: A Pilot Study
    Lairet, J. R.
    Bebarta, V
    Boudreau, S.
    King, J.
    ANNALS OF EMERGENCY MEDICINE, 2011, 58 (04) : S265 - S265
  • [6] Point-of-Care Lung Ultrasound for Bronchial Blocker Placement
    Yamaguchi, Yoshikazu
    Moharir, Alok
    Nomura, Takeshi
    Tobias, Joseph D.
    A & A PRACTICE, 2019, 13 (07): : 287 - 287
  • [7] Using point-of-care ultrasound Kidneys
    Breunig, Michael
    Kashiwagi, Deanne
    JAAPA-JOURNAL OF THE AMERICAN ACADEMY OF PHYSICIAN ASSISTANTS, 2019, 32 (02): : 44 - 47
  • [8] Using point-of-care ultrasound: Heart
    Breunig, Michael
    Kashiwagi, Deanne
    JAAPA-JOURNAL OF THE AMERICAN ACADEMY OF PHYSICIAN ASSISTANTS, 2018, 31 (12): : 45 - 50
  • [9] Using point-of-care ultrasound: Lungs
    Breunig, Michael
    Kashiwagi, Deanne
    JAAPA-JOURNAL OF THE AMERICAN ACADEMY OF PHYSICIAN ASSISTANTS, 2018, 31 (08): : 48 - 52
  • [10] Using point-of-care ultrasound: Shock
    Breunig, Michael
    Kashiwagi, Deanne
    JAAPA-JOURNAL OF THE AMERICAN ACADEMY OF PHYSICIAN ASSISTANTS, 2019, 32 (08): : 43 - 48