Active Magnetic Bearing System Using I-Type and U-Type Actuator

被引:9
|
作者
Das, Upama [1 ]
Debnath, Sukanta [1 ]
Gupta, Suraj [1 ]
Biswas, Pabitra Kumar [1 ]
Sudhakar Babu, Thanikanti [2 ,3 ]
Nwulu, Nnamdi I. [3 ]
机构
[1] Natl Inst Technol Mizoram, Dept Elect & Elect Engn, Aizawl 796012, India
[2] Chaitanya Bharathi Inst Technol, Dept Elect & Elect Engn, Hyderabad 500075, India
[3] Univ Johannesburg, Ctr Cyber Phys Food Energy & Water Syst, ZA-2006 Johannesburg, South Africa
关键词
Actuators; Rotors; Magnetic levitation; Force; Air gaps; Topology; Magnetic analysis; Active magnetic bearing; controllers; INDEX TERMS; hardware implementation; I-type and U-type actuator; magnetic analysis; load cell; DESIGN;
D O I
10.1109/ACCESS.2023.3276324
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
An active magnetic bearing (AMB) is an evolving research topic in the bearing industry. Compared to the conventional approach, AMB is more advantageous and has different industrial applications. The design of this bearing needs to be improvised to get more optimized performance. This leads us to focus on the better-designed structure of the actuator, which plays an essential role in AMB performance. Thus in this manuscript, we have designed and compared the I-type and U-type actuators' performances in terms of their resistance, inductance profile, and force profile to show the characteristics of these actuators. These designed actuators are simulated in Ansys Maxwell software, and compared with the simulation results. Further, these results are verified using hardware results, and the tested actuators are used to design two different AMB systems. One current controller is designed and simulated to achieve the stable levitated position of the rotor. This rotor is rotated by inserting an AC magnet in the system and finally, a rotational system is attained, and its speed is observed by the tachometer for both AMB systems. Both the proposed AMB systems are simple and compact in structure as these are having single coil and single power amplifier. These axial AMB systems are used in many high-speed applications as they are having features like less installation space, less cost and more room for heat dissipation.
引用
收藏
页码:62780 / 62798
页数:19
相关论文
共 50 条
  • [31] Balancing of U-type assembly systems using simulated annealing
    Erel, E
    Sabuncuoglu, I
    Aksu, BA
    INTERNATIONAL JOURNAL OF PRODUCTION RESEARCH, 2001, 39 (13) : 3003 - 3015
  • [32] Development of "tuned microwave absorbers" using U-type hexaferrite
    Meena, R. S.
    Bhattachrya, Sudeshna
    Chatterjee, Ratnamala
    MATERIALS & DESIGN, 2010, 31 (07) : 3220 - 3226
  • [33] ELECTRONIC EDITING IN PCM RECORDING USING A U-TYPE VTR
    MORI, T
    MATSUSHIGE, T
    YAMADA, Y
    KOSUDA, Y
    JOURNAL OF THE AUDIO ENGINEERING SOCIETY, 1981, 29 (05): : 356 - 356
  • [34] Peraluminous I-type granites
    Chappell, Bruce W.
    Bryant, Colleen J.
    Wyborn, Doone
    LITHOS, 2012, 153 : 142 - 153
  • [35] Monoids and groups of I-type
    Jespers, E
    Okninski, J
    ALGEBRAS AND REPRESENTATION THEORY, 2005, 8 (05) : 709 - 729
  • [36] Monoids and Groups of I-Type
    Eric Jespers
    Jan Okniński
    Algebras and Representation Theory, 2005, 8 : 709 - 729
  • [37] Determining the size and design of flow type and u-type warehouses
    Cakmak, Emre
    Gunay, Noyan Sebla
    Aybakan, Gulsah
    Tanyas, Mehmet
    8TH INTERNATIONAL STRATEGIC MANAGEMENT CONFERENCE, 2012, 58 : 1425 - 1433
  • [38] The ERG of guinea pig (Cavis porcellus):: comparison with I-type monkey and I-type rat
    Lei, B
    DOCUMENTA OPHTHALMOLOGICA, 2003, 106 (03) : 243 - 249
  • [39] Structure-Activity Relationship of a U-Type Antimicrobial Microemulsion System
    Zhang, Hui
    Taxipalati, Maierhaba
    Yu, Liyi
    Que, Fei
    Feng, Fengqin
    PLOS ONE, 2013, 8 (10):
  • [40] Frictional performance of U-type wavy tubes
    Chen, IY
    Lai, YK
    Wang, CC
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (05): : 880 - 886