Traumatic spinal cord injury (SCI) can lead to permanent neurological impairment, underscoring the urgency of regular therapeutic intervention and monitoring. In this study, we propose a new strategy for monitoring spinal cord injury through serum based on highresolution THz attenuated total reflection frequency domain spectroscopy (THz-ATR-FDS). We demonstrated serum spectral differences at different time points after experimental SCI in rats. We also studied the relationship between serum lipid concentration and the time of SCI, which revealed the potential of lipid molecules as biomarkers of SCI. In addition, based on the principal component analysis (PCA) and least squares regression (LSR) models, the quantitative relationship between the refractive index spectrum and lipid concentration in serum was automatically analyzed. This work highlights terahertz spectroscopy as a promising tool for label -free, periodic, and efficient monitoring of SCI.
引用
收藏
页码:479 / 490
页数:12
相关论文
共 50 条
  • [31] Dynamic frequency-domain interferometer for absolute distance measurements with high resolution
    Weng, Jidong
    Liu, Shenggang
    Ma, Heli
    Tao, Tianjiong
    Wang, Xiang
    Liu, Cangli
    Tan, Hua
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [32] FREQUENCY-LOCKED MODE-LOCKED CW DYE-LASER FOR HIGH-RESOLUTION SPECTROSCOPY IN THE FREQUENCY-DOMAIN
    COUILLAUD, B
    DUCASSE, A
    SARGER, L
    BOSCHER, D
    APPLIED PHYSICS LETTERS, 1980, 36 (01) : 1 - 3
  • [33] High-resolution Raman spectra with femtosecond pulses: An example of combined time- and frequency-domain spectroscopy
    Nath, Sukhendu
    Urbanek, Diana C.
    Kern, Sean J.
    Berg, Mark A.
    PHYSICAL REVIEW LETTERS, 2006, 97 (26)
  • [34] Wideband Radiation Pattern Measurement of Terahertz Antenna-Integrated Photodiodes by Frequency-Domain Spectroscopy
    Kolpatzeck, K.
    Liu, X.
    Friederich, B.
    Damyanov, D.
    Haring, L.
    Schultze, T.
    Balzer, J. C.
    Czylwik, A.
    2019 SECOND INTERNATIONAL WORKSHOP ON MOBILE TERAHERTZ SYSTEMS (IWMTS), 2019,
  • [35] High-frequency spinal cord stimulation in a subacute animal model of spinal cord injury
    DiMarco, Anthony F.
    Kowalski, Krzysztof E.
    JOURNAL OF APPLIED PHYSIOLOGY, 2019, 127 (01) : 98 - 102
  • [36] RESOLUTION OF 3-ROTATIONAL CORRELATION TIMES FOR PERYLENE BY FREQUENCY-DOMAIN FLUORESCENCE SPECTROSCOPY
    LAKOWICZ, JR
    GRYCZYNSKI, I
    CHEREK, H
    BIOPHYSICAL JOURNAL, 1988, 53 (02) : A87 - A87
  • [37] Sweeping of Terahertz Frequency Comb for High-Accuracy, High-Resolution, and Broadband Terahertz Spectroscopy
    Yasui, T.
    Hsieh, Y. -D.
    Iyonaga, Y.
    Inaba, H.
    Minoshima, K.
    Yokoyama, S.
    Araki, T.
    2012 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2012,
  • [38] High-resolution terahertz spectroscopy with a single tunable frequency comb
    Skryl, A. S.
    Pavelyev, D. G.
    Tretyakov, M. Y.
    Bakunov, M. I.
    OPTICS EXPRESS, 2014, 22 (26): : 32276 - 32281
  • [39] Diaphragm activation via high frequency spinal cord stimulation in a rodent model of spinal cord injury
    Kowalski, Krzysztof E.
    Hsieh, Yee-Hsee
    Dick, Thomas E.
    DiMarco, Anthony F.
    EXPERIMENTAL NEUROLOGY, 2013, 247 : 689 - 693
  • [40] HIGH-RESOLUTION ECHO ESTIMATION - AN APPLICATION OF PRONY METHOD IN THE FREQUENCY-DOMAIN
    MARTIN, U
    AEU-ARCHIV FUR ELEKTRONIK UND UBERTRAGUNGSTECHNIK-INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATIONS, 1989, 43 (03): : 181 - 183